marlow a global leader in thermoelectric solutions industries Subsidiary of II-VI Incorporated Thermoelectric Cooler RC12-2.5 RoHS 2002/95/EC Compliant Performance Values Hot Side Temperature 27C 50C (C) Tmax (C-dry N ): 66 74 2 Qmax (watts): 23 26 Imax (amps): 2.5 2.5 Vmax (vdc): 14.7 16.4 AC Resistance 4.9 --- (ohms): Mechanical Characteristics 1.181 29.9 POSITIVE LEAD (WHITE) + .800.33 1.181 29.9 20 AWG LEADS, PTFE INSULATION 20.328.38 NEGATIVE LEAD (BLACK) 4.00 .50 101.6 12.7 1.339 34.0 -01, -01S -01L, -01LS COLD SIDE, Tc .003 0.08 .002 0.05 A .002 0.05 .001 0.03 .002 0.05 .001 0.03 HOT SIDE, Th A -01, -01S .159.005 4.03 .13 -01L, -01LS .155.001 3.93 .03 Ceramic Material: Alumina (AC) Dimensions in are millimeters Ordering Options Features RoHS 2002/95/EC compliant Solid-state reliability. Model Number Description Built with high temperature solder with the ability to withstand higher assembly processing temperatures RC12-2.5-01 Base Model w/ leads for short periods of time (<160 C). RC12-2.5-01L Lapped Model Superior nickel diffusion barriers on elements High strength for rugged environment. RC12-2.5-01S Sealed Model Porched configuration for enhanced leadwire strength Lapped and Sealed RTV sealing available (Optional) RC12-2.5-01LS Model Lapped option available for multiple module applications. 214-340-4900 (tel) 214-341-5212 (fax) www.marlow.com Doc 102-0276 Rev A Page 1 of 2 MARLOW RC12-2.5 123456 USA -marlow a global leader in thermoelectric solutions industries Subsidiary of II-VI Incorporated Performance Curves Environment: One atmosphere dry nitrogen Hot Side Temperature: 27C Hot Side Temperature: 50C HEAT LOAD 80.0 80.0 HEAT (WATTS) LOAD 0.00 (WATTS) 2.50 0.00 60.0 60.0 5.00 2.50 7.50 5.00 10.0 7.50 40.0 40.0 12.5 10.0 15.0 12.5 17.5 15.0 20.0 20.0 20.0 17.5 22.5 20.0 25.0 22.5 0.0 0.0 16.0 16.0 12.0 12.0 8.0 8.0 Q=0 Q=0 T=0 T=0 4.0 4.0 0.0 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 CURRENT (AMPS) CURRENT (AMPS) For performance information in a vacuum or with hot side temperatures other than 27C or 50C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. Addresses Marlow Industries, Inc. Marlow Industries Europe Marlow Industries Japan 10451 Vista Park Road Aberdeen House, South Road 1-1-8-401 Dallas Texas 75238-1645 Haywards Heath Uehara, Shibuya-ku 214-340-4900 (tel) West Sussex RH164NG UK Tokyo, Japan 151-0064 214-341-5212 (fax) +44 (0)1444-443404 (tel) +81 (3) 5454-5280 (tel) www.marlow.com +44 (0)1444-443334(fax) +81 (3) 5454-5281(fax) 214-340-4900 (tel) 214-341-5212 (fax) www.marlow.com Doc 102-0276 Rev A Page 2 of 2 VOLTAGE (VDC) T (C) T (C) VOLTAGE (VDC)