TECHNICAL DATA SHEET marlow industries, inc. Subsidiary of II-VI INCORPORATED RC6-4 Single-Stage Thermoelectric Module RoHS EU Compliant TYPICAL PERFORMANCE VALUES Hot Side Temperature (C) 27C 50C Tmax (C-dry N): 65 73 2 Qmax (watts): 20 22 Imax (amps): 3.7 3.7 Vmax (vdc): 8.2 9.2 AC Resistance (ohms): 1.8 -- Device ZT 0.74 -- MECHANICAL CHARACTERISTICS * POSITIVE LEAD (WHITE) + .925 23.5 .59.25 14.996.35 20 AWG LEADS, TEFLON INSULATED * NEGATIVE LEAD (BLACK) 4.00 .50 .925 23.5 101 13 1.102 28.0 -01, -01S -01L, -01LS COLD SIDE, Tc* .003 0.08 .002 0.05 A .002 0.05 .001 0.03 .002 0.05 .001 0.03 HOT SIDE, Th A -01 & -01S .135.005 3.430.13 -01L & -01LS .131.001 3.330.03 RC6-4-05 Only + * POSITIVE LEAD (WHITE) * NEGATIVE LEAD (BLACK) 20 AWG LEADS, TEFLON INSULATED (3.60 91.4 ) Ceramic Material: Alumina (AC) Dimensions in are millimeters Dimensions in ( ) are references *NOTE: Cold side and positive and negative leads are valid only for thermoelectric cooling. For power generation, refer to page 3. ORDERING OPTIONS AVAILABLE MODIFICATIONS Model Number Description Solid-state reliability. Built with high temperature solder with the ability to withstand RC6-4-01 Base Model w/ leads higher assembly processing temperatures for short periods of RC6-4-01L Lapped Model time (<160 C). RC6-4-01S Sealed Model Superior nickel diffusion barriers on elements. RC6-4-01LS Lapped and Sealed Model High strength for rugged environment. RC6-4-05 Base Model w/ bent-leads Porched configuration for enhanced leadwire strength. RTV sealing available (Optional). Lapped option available for multiple module applications. DOC 102-0280 REV F - PAGE 1 OF 3 MARLOW MARLOW RC 6-4 RC 6-4 L 123456 123456 ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN Hot Side Temperature 50C Hot Side Temperature 27C 80.0 80.0 HEAT HEAT LOAD LOAD (WATTS) (WATTS) 60.0 0.00 0.00 60.0 2.50 2.50 40.0 5.00 5.00 40.0 7.50 7.50 10.0 20.0 10.0 12.5 20.0 12.5 15.0 15.0 0.0 0.0 8.0 10.0 6.0 8.0 6.0 4.0 Q=0 4.0 T=0 Q=0 2.0 T=0 2.0 0.0 0.0 0.0 1.0 2.0 3.0 4.0 5.0 0.0 1.0 2.0 3.0 4.0 5.0 CURRENT (AMPS) CURRENT (AMPS) For performance information in a vacuum or with hot side temperatures other than 27C or 50C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85C in a non-condensing environment is recommended. To minimize thermal stress when operating in cooling mode, use linear/proportional temperature control or a similar method rather than an ON/OFF method. CONTACT US: For customer support or general questions please contact a local office below or consult our website for distributor information. Marlow Industries, Inc. Marlow Industries Europe GmbH 10451 Vista Park Road Brunnenweg 19-21 Dallas Texas 75238-1645 64331 Weiterstadt 214-340-4900 (tel) Germany 214-341-5212 (fax) Tel.: +49 (0) 6150 5439 - 403 www.marlow.com Fax: +49 (0) 6150 5439 - 400 info marlow-europe.eu II-VI Japan Inc. II-VI Singapore Pte., Ltd. Marlow Industries China, II-VI WBG Marive East 17F Blk. 5012, Techplace II Technologies Beijing 2-6 Nakase, Mihama-ku 04-07 & 05-07/12, Ang Mo Kio Ave. 5 A subsidiary of II-VI Incorporated Chiba-Shi, Chiba 261-7117 Singapore 569876 Rm 202, 1 Lize 2nd Middle Road Japan (65) 6481 8215 (tel) Wangjing, Chaoyang District 81 43 297 2693 (tel) (65) 6481 8702 (fax) Beijing 100102 China 81 43 297 3003 (fax) info ii-vi.com.sg 010-64398226 ext 105 (tel) center ii-vi.co.jp www.ii-vi.com.sg 010-64399315 (fax) www.ii-vi.co.jp info iivibj.com DOC 102-0280 REV F - PAGE 2 OF 3 COOLING PERFORMANCE CURVES VOLTAGE (VDC) T (C) VOLTAGE (VDC) T (C)