CLC2023 Dual, Low Distortion, Low Offset, RRIO Amplifier FEATURES General Description 6mV maximum input offset voltage 0.00005% THD at 1kHz The CLC2023 is a dual channel, high-performance, voltage feedback 5.3nV/Hz input voltage noise > 10kHz amplifier with low input voltage noise and ultra low distortion. The CLC2023 -90dB/-85dB HD2/HD3 at 100kHz, R = 100 offers 6mV maximum input offset voltage, 3.5nV/Hz broadband input L <-100dB HD2 and HD3 at 10kHz, R = 1k voltage noise, and 0.00005% THD at 1kHz. It also provides 55MHz gain L Rail-to-rail input and output bandwidth product and 12V/s slew rate making them well suited for 55MHz unity gain bandwidth applications requiring precision DC performance and high AC performance. 12V/s slew rate This high-performance amplifier also offers a rail-to-rail input and output, -40C to +125C operating temperature simplifying single supply designs and offering larger dynamic range range possibilities. The input range extends beyond the rails by 300mV. Fully specified at 3 and 5V supplies The CLC2023 is designed to operate from 2.5V to 12V supplies and CLC2023: ROHS compliant MSOP-8, operate over the extended temperature range of -40C to +125. SOIC-8 package options APPLICATIONS Active filters Sensor interface HIgh-speed transducer amp Medical instrumentation Probe equipment Test equipment Smoke detectors Hand-held analytic instruments Current sense applications Ordering Information - back page Crosstalk vs. Frequency Typical Application -60 +2.7 -65 6.8F -70 + -75 -80 0.1F In + -85 Out CLC2023 R -90 IN R OUT - -95 Vs = +/- 5V, RL = 150, V = 2V OUT pp -100 R g 0.01 0.1 1 R f Frequency (MHz) 2007-2014 Exar Corporation 1 / 18 exar.com/CLC2023 Rev 1D Crosstalk (dB)CLC2023 Absolute Maximum Ratings Operating Conditions Supply Voltage Range ................................................. 2.5V to 12V Stresses beyond the limits listed below may cause permanent damage to the device. Exposure to any Absolute Operating Temperature Range ...............................-40C to 125C Maximum Rating condition for extended periods may affect Junction Temperature ...........................................................150C device reliability and lifetime. Storage Temperature Range ...................................-65C to 150C Lead Temperature (Soldering, 10s) ......................................260C V ................................................................................. 0V to +14V S V ............................................................ -V - 0.5V to +V +0.5V IN S S Package Thermal Resistance (MSOP-8) .................................................................. 200C/W JA (SOIC-8) .....................................................................150C/W JA Package thermal resistance ( ), JEDEC standard, multi-layer JA test boards, still air. 2007-2014 Exar Corporation 2 / 18 exar.com/CLC2023 Rev 1D