2.7V 100F BCAP0100 P270 S01 ESHSR-0100C0-002R7 FEATURES ELECTRICAL SPECIFICATIONS Rated Voltage, V 2.7 VDC R High performance product with low ESR 1 Surge Voltage 2.85 VDC Exceptional shock and vibration resistance 2 Rated Capacitance, C 100 F Long lifetimes with up to 500,000 duty cycles* Min. / Max. 0% / +20% Capacitance Tolerance 4 Compliant with UL, RoHS, and REACH requirements Average +5% / +10% Recommended Application: Max. 12 m 3 Initial DC-ESR, R DC 4 Average 8 m Automotive, UPS System, Actuators, Emergency Lighting, 5 Maximum Leakage Current 0.26 mA Telematics, Security Equipment, Backup System, and Others 6 Maximum Peak Current, Non-repetitive 60 A TYPICAL LIFETIME CHARACTERISTICS* 8 Projected DC Life at Room Temperature 10 years (Continuous charging at V and 25 10 C) R 8 DC Life at Standard High Temperature 1,500 hours (Continuous charging at V and 65C) R 8 DC Life at De-Rated Voltage & Higher Temp. 1,000 hours (Continuous charging at 2.3V and 85C) 8 Projected Cycle Life at Room Temperature 500,000 (Constant current charge-discharge from V to R cycles 1/2V at 25 10 C) R Shelf Life 4 years (Stored without charge at 25 10 C) TYPICAL THERMAL CHARACTERISTICS Thermal Resistance, R (Housing) 11.6 C/W th Thermal Capacitance, C 34.5 J/C th 9 Usable Continuous Current (T = 15C) 10 A 9 Usable Continuous Current (T = 40C) 17 A 10 See Note on Mounting Recommendations DIMENSION & WEIGHT D (+1.0) 22.0 mm L (1.0) 46.0 mm H (1.0) 6.0 mm d (0.05) 1.5 mm A (0.2) 10.0 mm Nominal Weight 21.1 g SAFETY & ENVIRONMENTAL RoHS & REACH & UL Compliant OPERATING ENVIRONMENT / POWER & ENERGY Operating Temperature Range Standard (-40C to 65C) Extended (-40C to 85C) 7 Maximum Stored Energy, E at 2.7V 0.10 Wh at 2.3V 0.07 Wh max 7 Gravimetric Specific Energy at 2.7V 4.8 Wh/kg at 2.3V 3.4 Wh/kg 7 Usable Specific Power at 2.7V 3.4 kW/kg at 2.3V 2.5 kW/kg 7 Impedance Match Specific Power at 2.7V 7.2 kW/kg at 2.3V 5.2 kW/kg *Results may vary. Additional terms and conditions, including the limited warranty, apply at the time of purchase. See the warranty details for applicable operating and use requirements. 3001959-EN.1 Page 1 of 2 2.7V 100F BCAP0100 P270 S01 NOTE 1. Surge Voltage 6. Maximum Peak Current Absolute maximum voltage, non-repetitive. The duration must not exceed 1 Current that can be used for 1-second discharging from the rated voltage to the second. half-rated voltage under the constant current discharging mode. = 2. Rated Capacitance (Measurement Method) / 5 Constant current charge with 10 mA per farad to V . R where is the maximum peak current (A) e.g. In case of 2.7V 100F cell, 10 * 100 = 1,000 mA = 1A is the rated voltage (V) Constant voltage charge at V for 5 min. R is the discharge time (sec) = 1 sec in this case Constant current discharge with 10 mA per farad to 0.1V. is the rated capacitance (F) is the maximum DC-ESR () The stated maximum peak current should not be used in normal operation and is only provided as a reference value. 7. Energy & Power (Based on IEC 62391-2) Maximum Stored Energy, E (Wh) = max Gravimetric Specific Energy (Wh/kg) = ( ) ) = . ) Usable Specific Power (W/kg) = where is the capacitance (F) . is the absolute value of the discharge current (A) Impedance Match Specific Power (W/kg) = is the measurement starting voltage, 0.8V (V) R is the measurement end voltage, 0.4V (V) R 8. DC Life and Cycle Life Test is the time from discharge start to reach (s) End-of-Life (EOL) Conditions: is the time from discharge start to reach (s) - Capacitance: -20% from the rated minimum value - DC-ESR: +100% from the specified maximum initial value 3. Initial DC-ESR (Measurement Method) Capacitance and ESR measurements are taken at 25C. Constant current charge with 10 mA per farad to V . R Constant voltage charge at V for 5 min. R 9. Usable Continuous Current Constant current discharge with 40 * C * V mA to 0.1V. R Maximum current which can be used within the allowed temperature range under e.g. In case of 2.7V 100F cell, 40 * 100 * 2.7 = 10,800 mA = 10.8A the constant current discharging mode. = where is the maximum continuous current (A) is the change in temperature (C) is the thermal resistance (C/W) is the maximum DC-ESR () 10. Mounting Recommendations Provide properly spaced holes for mounting according to the specified cell dimension in order to minimize the terminals of the cell being mechanically stressed. = Do not place any through-holes directly underneath the cell or in the close proximity of the cell. Allow at least 5mm distance from any point on the outer diameter of the where is the DC-ESR () cell to the outer diameter of any through-hole. is the voltage drop during first 10ms of discharge (V) Protective coating of components on the PCB is strongly recommended in order to is the absolute value of the discharge current (A) reduce the risk of the components being damaged in an event of electrolyte leakage. Provide at least 2mm clearance from the safety vent and do not position anything 4. Average near the safety vent that may be damaged by the vent rupture. Typical percentage spread that may be present in one shipment. Assemble the cell on the PCB taking into account that the cell may not be completely hermetic during its lifetime. Electrolyte vapor and gases generated during normal 5. Maximum Leakage Current (Measurement Method) operation may escape the package. The capacitor is charged to its rated voltage VR at 25C. Soldering guide for small and medium size cells is available and can be found at Leakage current is the amount of current measured after 72 hours of continuous www.nesscap.com under Support -> Download. holding of the capacitor at V . R When ordering, please reference the Maxwell Model Number below. Maxwell Model Number: Maxwell Part Number: Nesscap Model Number: BCAP0100 P270 S01 133522 ESHSR-0100C0-002R7 Maxwell Technologies, Inc. Maxwell Technologies SA Maxwell Technologies, GmbH Maxwell Technologies Nesscap Co., Ltd. Global Headquarters Route de Montena 65 Leopoldstrasse 244 17, Dongtangiheung-ro 681beon-gil, Shanghai Trading Co., Ltd 3888 Calle Fortunada CH-1728 Rossens 80807 Munich Room 1005, 1006, 1007 Giheung-gu, Yongin-si, San Diego, CA 92123 Switzerland Germany No. 1898, Gonghexin Road, Gyeonggi-do USA Tel: +41 (0)26 411 85 00 Tel: +49 (0)89 4161403 0 17102 Jing An District, Shanghai 200072 Tel: +1 (858) 503-3300 Fax: +41 (0)26 411 85 05 Fax: +49 (0)89 4161403 99 Republic of Korea P.R. China Fax: +1 (858) 503-3301 Tel: +86 21 3680 4600 Tel: +82 31 289 0721 Fax: +82 31 286 6767 Fax: +86 21 3680 4699 The data in this document 3001959 corresponds to the data in Nesscap document 20170711 Rev05. The information in this document is correct at time of printing and is subject to change without notice. Images are not to scale. MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGYS FUTURE, NESSCAP, BOOSTCAP, D CELL, CONDIS and their respective designs and/or logos are either trademarks or registered trademarks of Maxwell Technologies, Inc., and/or its affiliates, and may not be copied, imitated or used, in whole or in part, without the prior written permission Maxwell Technologies, Inc. All contents copyright 2017 Maxwell Technologies, Inc. All rights reserved. No portion of these materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc. 3001959-EN.1 Page 2 of 2