5W AC-DC Single Output Wall-mounted type
G S05U-USB
Features :
Universal AC input / Full range
No load power consumption <0.3W
Compact size
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class I I power (without earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Pass LPS
100% full load burn-in test
Fully enclosed plastic case
Low cost, high reliability
2 years warranty
SPECIFICATION
ORDER NO. GS05U-USB
SAFETY MODEL NO. GUSB05
DC VOLTAGE Note.2 5V
RATED CURRENT 1.00A
CURRENT RANGE 0 ~ 1.00A
RATED POWER 5W
OUTPUT
RIPPLE & NOISE (max.) Note.3 90mVp-p
VOLTAGE TOLERANCE Note.4 4.0%
LINE REGULATION Note.5 1.0%
LOAD REGULATION Note.6 4.0%
SETUP, RISE, HOLD UP TIME 1500ms, 20ms, 15ms at full load
VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) Note.7 69%
INPUT
AC CURRENT 0.15A / 100VAC
INRUSH CURRENT (max.) 35A / 230VAC
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
105 ~ 135% rated output voltage power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 160% rated output voltage, detect on main control IC
PROTECTION OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
U1 Tj 135 typically (U1) detect on main control IC
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP. -20 ~ +50(Refer toDerating curv)
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
0.03% / (0 ~ 50)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, CSA22.2 approved
SAFETY &
WITHSTAND VOLTAGE
I/P-O/P:4242VDC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
(Note. 8)
EMI CONDUCTION & RADIATION Compliance to FCC part 15 Class B
MTBF 1100Khrs min. MIL-HDBK-217F(25)
41.86*32.76*23.8mm (L*W*H)
OTHERS DIMENSION
26g ; 102pcs / 5Kg / CARTON
PACKING
PLUG USB Type A
CONNECTOR
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 115VAC.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS05U-USB-SPEC 2013-11-145W AC-DC Single Output Wall-mounted type
G S05U-USB
Mechanical Specification
Unit:mm
41.86
17
32.76
12.4
21.9
22.4
USB Type A
+ -
4 3 2 1
Derating Curve Static Characteristics
100 100
80
60
60
-20 10 20 30 40 50 0 50 60 70 80 90 100 264
Ta () INPUT VOLTAGE
File Name:GS05U-USB-SPEC 2013-11-14
LOAD (%)
13.05
12.5
12.7
LOAD (%)
23.8
5.05