6W AC-DC Reliable Green Medical Adaptor G SM 06E series Users Manual Video + + File Name:GSM06E-SPEC 2021-12-086W AC-DC Reliable Green Medical Adaptor G SM 06E series SPECIFICATION ORDER NO. GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J SAFETY MODEL NO. GSM06E05 GSM06E06 GSM06E07 GSM06E09 GSM06E12 GSM06E15 GSM06E18 GSM06E24 DC VOLTAGE Note.2 5V 6V 7.5V 9V 12V 15V 18V 24V RATED CURRENT 1.2A 1A 0.8A 0.66A 0.5A 0.4A 0.33A 0.25A CURRENT RANGE 0 ~ 1.2A 0 ~ 1A 0 ~ 0.8A 0 ~ 0.66A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.33A 0 ~ 0.25A RATED POWER 6W 6W 6W 6W 6W 6W 6W 6W OUTPUT RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0% 5.0% 5.0% 5.0% 5.0% 4.0% LINE REGULATION Note.5 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.6 5.0% 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.0% SETUP, RISE, HOLD UP TIME 1000ms, 50ms, 12ms at full load VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 68% 74% 74% 76% 77% 79% 80% 82% INPUT AC CURRENT 0.18A / 100VAC INRUSH CURRENT (max.) Cold start 15A/ 115VAC 30A / 230VAC LEAKAGE CURRENT(max.) Touch current < 50A/264VAC >105% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 110 ~ 140% rated output power OVER VOLTAGE Protection type : Clamp by zener diode WORKING TEMP. 0 ~ +50(Refer toDerating Curv) WORKING HUMIDITY 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.04% / (0 ~ 40) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes TUV BS EN/EN60601-1, BS EN/EN60601-1-11, EAC TP TC 004 approved SAFETY STANDARDS ISOLATION LEVEL Pimary - Secondary: 2 x MOPP WITHSTAND VOLTAGE I/P-O/P:5656VDC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted emission BS EN/EN55011 (CISPR11) Class B BS EN/EN55011 (CISPR11) Class B EMC EMISSION Radiated emission Harmonic current BS EN/EN61000-3-2 Class A SAFETY & Voltage flicker BS EN/EN61000-3-3 ----- EMC BS EN/EN55024 , BS EN/EN60601-1-2, BS EN/EN61204-3 (Note. 7) Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air Level 4, 8KV contact Level 3, 10V/m(80MHz~2.7GHz) RF field susceptibility BS EN/EN61000-4-3 Table 9, 9~28V/m(385MHz~5.78GHz) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV EMC IMMUNITY Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m >95% dip 0.5 periods, 30% dip 25 periods, Voltage dip, interruption BS EN/EN61000-4-11 >95% interruptions 250 periods MTBF 500Khrs min. MIL-HDBK-217F(25) OTHERS DIMENSION 32*66*42.5mm (L*W*H) 100g 90pcs / 10Kg / CARTON PACKING PLUG See page 4~5 Other type available by customer requested CONNECTOR See page 4~5 Other type available by customer requested CABLE NOTE