375W Quad Output with PFC Function Q P- 375 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH3,4 are isolated from other outputs and the polarity can be reversed No minimum load requirement for CH2,3,4 All output can be adjustable from -5~+10% With power good and fail signal output Built-in remote ON-OFF control Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL QP-375-5A QP-375-5B QP-375-5C OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE +5V +12V 12V 12V +5V +12V 12V 5V +5V +12V 15V 15V RATED CURRENT 30A 10A 6A 3A 30A 10A 6A 3A 30A 9A 4A 4A CURRENT RANGE 3.5 ~ 40A 0 ~ 16A 0 ~ 6A 0 ~ 3A 3.5 ~ 40A 0 ~ 16A 0 ~ 6A 0 ~ 3A 3.5 ~ 40A 0 ~ 16A 0 ~ 4A 0 ~ 4A RATED POWER(max.) 378W 357W 378W RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 50mVp-p 100mVp-p 120mVp-p 120mVp-p 50mVp-p 100mVp-p 150mVp-p 150mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V 11.4 ~ 13.2V 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V ------ 4.75 ~ 5.5V 11.4 ~ 13.2V 14.3 ~ 16.5V 14.3 ~ 16.5V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 36ms at full load VOLTAGE RANGE Note.7 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 77% 77% 77% AC CURRENT (Typ.) 6A/115VAC 3A/230VAC INRUSH CURRENT (Typ.) COLD START 45A LEAKAGE CURRENT <2mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 80 5 (TSW1) Detect on heatsink of Q1,Q2 power transistor) OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms FUNCTION RC+/RC-:0 ~ 0.8V POWER ON 4V ~ 10V POWER OFF REMOTE CONTROL -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0~50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 75.9K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 280*127*63.5mm (L*W*H) 2.4Kg 6pcs/14.8Kg/0.89CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on 375W Quad Output with PFC Function Q P-375 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH3,4 are isolated from other outputs and the polarity can be reversed No minimum load requirement for CH2,3,4 All output can be adjustable from -5~+10% With power good and fail signal output Built-in remote ON-OFF control Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL QP-375-5D QP-375-5E OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE +5V +12V 12V 24V +5V +12V 24V 24V RATED CURRENT 30A 9A 4A 3A 30A 9A 3A 2A CURRENT RANGE 3.5 ~ 40A 0 ~ 16A 0 ~ 6A 0 ~ 3A 3.5 ~ 40A 0 ~ 16A 0 ~ 4A 0 ~ 3A RATED POWER(max.) 378W 378W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 120mVp-p 240mVp-p 100mVp-p 120mVp-p 120mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V 22.8 ~ 26.4V 4.75 ~ 5.5V 11.4 ~ 13.2V 22.8 ~ 26.4V 22.8 ~ 26.4V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 36ms at full load VOLTAGE RANGE Note.7 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load EFFICIENCY (Typ.) 78% 78% INPUT AC CURRENT (Typ.) 6A/115VAC 3A/230VAC INRUSH CURRENT (Typ.) COLD START 45A LEAKAGE CURRENT <2mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 80 5 (TSW1) Detect on heatsink of Q1,Q2 power transistor) OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 10ms/1ms POWER GOOD / POWER FAIL(OPTIONAL) FUNCTION RC+/RC-:0 ~ 0.8V POWER ON 4V ~ 10V POWER OFF REMOTE CONTROL -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY -20 ~ +85 , 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0~50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A EMC IMMUNITY MTBF 75.9K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 280*127*63.5mm (L*W*H) 2.4Kg 6pcs/14.8Kg/0.89CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on