100W Single Output with PFC Function L PP-100 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . c o m ID 2000000000 SPECIFICATION MODEL LPP-100-3.3 LPP-100-5 LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.3A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A RATED POWER 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 600ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 28ms/230VAC 28ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF >0.95/230VAC PF >0.98/115VAC at full load INPUT EFFICIENCY(Typ.) 69% 75% 76% 79% 79% 80% 83% 83% 83% AC CURRENT (Typ.) 1.7A/115VAC 0.75A/230VAC INRUSH CURRENT (Typ.) COLD START 30A/230VAC LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 3.8 ~ 4.45V 5.75 ~ 6.75V 8.6 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -10 ~ +60 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, criteria A, EAC TP TC 020 MTBF 224.3Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 222*62*33.6mm (L*W*H) PACKING 0.51Kg 24pcs/13.9Kg/1.63CUFT NOTE (as available on 4-3.5 100W Single Output with PFC Function L PP-100 series Mechanical Specification Unit:mm 222 5 212 CN2 1 CN1 5 4 3 2 1 F4A/250V 8 +V ADJ. AC Input Connector (CN1) : JST B5P-VH or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal 1 AC/L 1,2,3,4 -V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 2,4 No Pin JST VHR JST SVH-21T-P1.1 5,6,7,8 +V or equivalent or equivalent 3 AC/N 5 FG : Grounding Required CN1:Pin 5 is safety ground Block Diagram PFC fosc : 67KHz PWM fosc : 134KHz RECTIFIERS EMI FILTER PFC POWER +V I/P & & CIRCUIT SWITCHING -V RECTIFIERS FILTER COSTANT CURRENT LIMITING & FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 Forced Air 100 3.3 ~ 7.5V 90 With 18CFM 80 (15cm) 80 Forced Air 70 60 Convection 12 ~ 48V With No FAN 3.3V ~ 7.5V With NO FAN 60 40 50 20 40 -10 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 115 135 155 230 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:LPP-100-SPEC 2021-07-05 LOAD (%) 62 3 max. 33.6 52 5 LOAD (%)