150W Single Output Switching Power Supply L RS-150 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . c o m ID 2000000000 GB4943.1 AS/NZS62368-1 UL62368-1 EN62368-1 TP TC004 IEC62368-1 File Name:LRS-150-SPEC 2020-10-14150W Single Output Switching Power Supply L RS-150 series SPECIFICATION MODEL LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-36 LRS-150-48 DC VOLTAGE 12V 15V 24V 36V 48V RATED CURRENT 12.5A 10A 4.3A 3.3A 6.5A 0 ~ 12.5A 0 ~ 10A 0 ~ 4.3A 0 ~ 3.3A CURRENT RANGE 0 ~ 6.5A 150W 154.8W RATED POWER 150W 156W 158.4W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 10.2 ~ 13.8V 13.5 ~ 18V 32.4 ~ 39.6V 43.2 ~ 52.8V 21.6 ~ 28.8V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load HOLD UP TIME (Typ.) 40ms/230VAC 35ms/115VAC at full load VOLTAGE RANGE 85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC) FREQUENCY RANGE 47 ~ 63Hz 89% EFFICIENCY (Typ.) 87.5% 88.5% 89% 90% INPUT AC CURRENT (Typ.) 3A/115VAC 1.7A/230VAC INRUSH CURRENT (Typ.) COLD STAR 60A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC 110 ~ 140% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes OVER VOLTAGE CATEGORY Compliance to EN61558, EN50178, EN60664-1, EN62477-1 altitude up to 2000 meters UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1 / -2 -16 ,CCC GB4943.1, BSMI CNS14336-1, SAFETY STANDARDS EAC TP TC 004,KC K60950-1(for LRS-150-12 only) ,AS/NZS 62368.1(by CB) approved I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 7) Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2 Class A(75% Load),EN61000-3-3, EMC EMISSION GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020, KC KN32,KN35(for LRS-150-12 only) MTBF 601K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 159*97*30mm (L*W*H) PACKING 0.48Kg 30pcs/15.4Kg/0.75CUFT NOTE ,