450W/650W/1000W Modular Power
MP series
Features :
ZVT technology to reduce power dissipation and improve efficiency
Various output configuration is selectable
Built in active PFC, PF>0.95
Universal AC input/ full range
Remote Control on every individual output module
Remote Sense on every individual output module(MS-75,150,300)
Built in parallel function(MS-300)
Protections: Short circuit / Overload / Over voltage for all output modules
Additional 12V/0.1A auxiliary output for remote control
Cooling by built-in DC fan with fan alarm function
3 years warranty
Output Configuration Guide
MP - -
Single output(MS-150) Single output(MS-300) Single output(MS-75) Dual output(MD-100)
1 SLOT (150W max.) 2 SLOT (300W max.) 1 SLOT (75W max.) 1 SLOT (100W max.)
SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7
450/650/1K0(450W/650W/1000W) Voltage code Voltage
Voltage code Voltage Voltage code Voltage Voltage code Voltage
Modular Power with PFC
A 2V 2A 2V L 3.3V 5V
R
450W/650W(5SLOT)
Parallel or option code B 3.3V 2B 3.3V M 5V 5V
1000W(7SLOT) (See Table 1.)
C 5V 2C 5V N 12V 5V
S
D 7.5V 2D 7.5V O 15V 12V
Example: MP1K0- A 2 E # S 2 K
E 12V 2E 12V P 24V 5V
T
F 15V 2F 15V Q 48V 15V
SLOT1
G 18V 2G 18V 24V
O/P:2V@25A U
H 24V 2H 24V 5V
SLOT2,3
I 27V 2I 27V 24V
O/P:12V@25A V
J 33V 2J 33V 12V
SLOT4
K 48V 2K 48V 12V
Blank Slot
W
12V
SLOT5
15V
O/P:5V@10A
X
15V
12V@4.2A
SLOT6,7
O/P:48V@6.3A
SPECIFICATION
MODEL PFC-450 PFC-650 PFC-1000
VOLTAGE RANGE 85 ~ 264VAC 120 ~370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT EFFICIENCY Note.1 83% typ. 85% typ. 84% typ.
AC CURRENT 6.3A/115VAC 3.2A/230VAC 9A/115VAC 4.5A/230VAC 13.5A/115VAC 6.7A/230VAC
INRUSH CURRENT 25A/115VAC 40A/230VAC 30A/115VAC 50A/230VAC 20A/115VAC 40A/230VAC
LEAKAGE CURRENT <1.5mA/240VAC
650W max. 1000W max.
OUTPUT TOTAL OUTPUT POWER 450W max.
Thermal switch detect on the heatsink of power MOSFET
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PROTECTION
Output shutdown when FAN is malfunction
FAN ALARM
REMOTE CONTROL RC+/RC-: 0 ~ 0.8V or Short, Power ON RC+/RC-: 4 ~ 12V or Open, Power OFF
FUNCTION
AUXILIARY POWER(AUX) 12V@0.1A(only for Remote ON/OFF Control)
-20 ~ +70 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
VIBRATION
SAFETY STANDARDS UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 5)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-1, EN61204-3 Light industry level, criteria A
DIMENSION 254*127*63.5mm (L*W*H) 278*127*63.5mm (L*W*H) 278*177.8*63.5mm (L*W*H)
OTHERS
PACKING 1.8Kg(typ.); 6pcs / 11.8Kg / 1.25CUFT 2.16Kg(typ.); 6pcs / 14Kg / 1.34CUFT 3Kg(typ.); 6pcs /19Kg / 1.74CUFT
MeanWell Direct
E-mail: sales@meanwelldirect.co.uk450W/650W/1000W Modular Power
MP series
SPECIFICATION
1 SLOT Single output (150W) MS-150
OUTPUT VOLTAGE CODE MS-150A MS-150B MS-150C MS-150D MS-150E MS-150F MS-150G MS-150H MS-150I MS-150J MS-150K
DC VOLTAGE 2V 3.3V 5V 7.5V 12V 15V 18V 24V 27V 33V 48V
RATED CURRENT 25A 25A 25A 18A 13A 10A 8.5A 6.5A 5.8A 4.7A 3.2A
CURRENT RANGE 0 ~ 25A 0 ~ 25A 0 ~ 25A 0 ~ 18A 0 ~ 13A 0 ~ 10A 0 ~ 8.5A 0 ~ 6.5A 0 ~ 5.8A 0 ~ 4.7A 0 ~ 3.2A
PEAK LOAD Note.4 30A 30A 30A 20.7A 15A 11.5A 9.8A 7.5A 6.7A 5.4A 3.68A
RATED POWER 50W 82.5W 125W 135W 156W 150W 153W 156W 156.6W 155.1W 153.6W
OUTPUT
(MS-150)
RIPPLE & NOISE (max.) Note.2 50mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 1.6 ~ 2.6V 2.6 ~ 4V 4 ~ 6V 6 ~ 9V 9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V 30 ~ 40V 40 ~ 53V
VOLTAGE TOLERANCE Note.3 3.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.3% 0.3% 0.3% 0.2% 0.2% 0.2% 0.2%
LOAD REGULATION 2.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
121 ~ 150% rated output power 116 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
2.7 ~ 4V 4.1 ~ 5V 6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION REMOTE INHIBIT CONTROL RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON RC+/RC-: 4 ~ 12V POWER OFF
2 SLOT Single output (300W) MS-300
OUTPUT VOLTAGE CODE MS-300-2A MS-300-2B MS-300-2C MS-300-2D MS-300-2E MS-300-2F MS-300-2G MS-300-2H MS-300-2I MS-300-2J MS-300-2K
DC VOLTAGE 2V 3.3V 5V 7.5V 12V 15V 18V 24V 27V 33V 48V
RATED CURRENT 50A 50A 50A 40A 25A 20A 16.7A 12.5A 11.2A 9.1A 6.3A
CURRENT RANGE 0 ~ 50A 0 ~ 50A 0 ~ 50A 0 ~ 40A 0 ~ 25A 0 ~ 20A 0 ~ 16.7A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 9.1A 0 ~ 6.3A
PEAK LOAD Note.4 57.5A 57.5A 57.5A 46A 29A 23A 19.2A 14.4A 12.9A 10.5A 7.2A
RATED POWER 100W 165W 250W 300W 300W 300W 300.6W 300W 302.4W 300.3W 302.4W
OUTPUT
(MS-300)
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 300mVp-p
VOLTAGE ADJ. RANGE 1.6 ~ 2.6V 2.6 ~ 4V 4 ~ 6V 6 ~ 9V 9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V 30 ~ 40V 40 ~ 53V
VOLTAGE TOLERANCE Note.3 3.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.3% 0.3% 0.3% 0.2% 0.2% 0.2% 0.2%
LOAD REGULATION 2.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% 1.0%
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
116 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
3 ~ 4V 4.1 ~ 5V 6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION REMOTE INHIBIT CONTROL RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON RC+/RC-: 4 ~ 12V POWER OFF
1 SLOT Single output (75W) MS-75
OUTPUT VOLTAGE CODE MS-75L MS-75M MS-75N MS-75O MS-75P MS-75Q
DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 15A 15A 6.3A 5A 3.2A 1.6A
CURRENT RANGE 0 ~ 15A 0 ~ 15A 0 ~ 6.3A 0 ~ 5A 0 ~ 3.2A 0 ~ 1.6A
PEAK LOAD Note.4 17.3A 17.3A 7.3A 5.8A 3.7A 1.8A
RATED POWER 49.5W 75W 75.6W 75W 76.8W 76.8W
OUTPUT
(MS-75)
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 150mVp-p 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 2.6 ~ 4V 4 ~ 6V 9 ~ 13.2V 13.2 ~ 16.8V 20 ~ 26.4V 40 ~ 53V
VOLTAGE TOLERANCE Note.3 2.0% 2.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.3% 0.3% 0.2% 0.2%
LOAD REGULATION 1.0% 1.0% 0.5% 0.5% 0.5% 0.5%
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
116 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
4.1 ~ 5V 6.1 ~ 7.5V 13.3 ~ 18V 16.9 ~ 22V 26.5 ~ 35V 53.1 ~ 60V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION REMOTE INHIBIT CONTROL RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON RC+/RC-: 4 ~ 12V POWER OFF
MeanWell Direct
E-mail: sales@meanwelldirect.co.uk