400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter NTS-400P series E13 IEC62368-1 TPTC004 AS/NZS 62368.1 - / File Name:NTS-400P-SPEC 2021-03-15400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter NTS-400P series SPECIFICATION MODEL NO. NTS-400P-112 NTS-400P-124 NTS-400P-148 NTS-400P-212 NTS-400P-224 NTS-400P-248 RATED POWER(Continuous) 400W OVER RATED POWER(3 Min.) 460W PEAK POWER(10 Sec.) 600W SURGE POWER(30 Cycles) 800W Default setting set at 110VAC Default setting set at 230VAC AC VOLTAGE AC OUTPUT 100 / 110 / 115 / 120Vac selectable by DIP S.W 200 / 220 / 230 / 240Vac selectable by DIP S.W Default setting set at 60Hz 0.1Hz Default setting set at 50Hz 0.1Hz FREQUENCY 50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W WAVEFORM Note.1 True sine wave (THD<3%) AC REGULATION 3.0% at rated input voltage LED STATUS Please refer to page3 DC VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc DC CURRENT (Typ.) 40A 40A 20A 10A 20A 10A 10W 10W Non-Saving mode 10W 12W 10W 12W NO LOAD DC INPUT DISSPATION Default disable, 1.2W ~ 1.5W by models auto detec AC output load 10W will be changed to saving mode Saving mode (Typ.) 1.2W 1.2W 1.3W 1.5W 1.3W 1.5W OFF MODE CURRENT DRAW <1mA at battery ~DC input must be disconnected EFFICIENCY (Typ.) Note.1 89% 91% 91% 91% 93% 93% Lead Acid or Li-ion BATTERY TYPES FUSE(Internal) 40A*2 30A*2 10A*2 40A*2 30A*2 10A*2 ALARM 11 0.3Vdc 22 0.5Vdc 441Vdc 110.3Vdc 220.5Vdc 441Vdc LOW SHUTDOWN 100.3Vdc 20 0.5Vdc 401Vdc 100.3Vdc 200.5Vdc 401Vdc RESTART 12.5 0.3Vdc 25 0.5Vdc 501Vdc 12.50.3Vdc 250.5Vdc 501Vdc ALARM 15.5 0.3Vdc 31 0.5Vdc 621Vdc 15.50.3Vdc 310.5Vdc 621Vdc HIGH SHUTDOWN 16.5 0.3Vdc 33 0.5Vdc 661Vdc 16.50.3Vdc 330.5Vdc 661Vdc RESTART 15 0.3Vdc 30 0.5Vdc 601Vdc 150.3Vdc 300.5Vdc 601Vdc By internal fuse open BAT. POLARITY OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work Short : Remote off REMOTE CONTROL FUNCTION Tx/Rx Support Tx/Rx for monitoring power inverter status WORKING TEMP. -20 ~ +70(Refer to Derating curve) WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes CB IEC62368-1 for all models E13, EAC TPTC004,AS/NZS 62368.1 for NTS-400P-212/224/248 SAFETY STANDARDS WITHSTAND VOLTAGE DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac Parameter Standard Test Level / Note FCC for 112,124,148 only Class A Radiated EMC EMISSION EN55032(CISPR32) for 212,224,248 only Class A SAFETY & Harmonic Current EN61000-3-2 ----- EMC Voltage Flicker EN61000-3-3 ----- (Note.3) Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air Level 4, 8KV contact EMC IMMUNITY Radiated EN61000-4-3 Level 2, 3V/m Magnetic Field EN61000-4-8 Level 1, 1A/m MTBF 278.7K hrs min. Telcordia TR/SR-332 (Bellcore) 84K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 186*100.5*32mm (L*W*H) 0.75Kg 18pcs/ 14.5Kg/ 0.97CUFT PACKING NOTE