200W Quad Output with PFC Function Q P-200 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH1,2 can be adjustable from -5~+10% With power good and fail signal output(Optional) Built-in remote sense function for CH1,2 100% full load burn-in test CH4 can set to positive after consult us before delivery(Optional) Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty .. SPECIFICATION MODEL QP-200D QP-200F QP-200-3A OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 12V 24V -12V 5V 15V 24V -15V 5V 3.3V 12V -5V 5V RATED CURRENT 15A 4A 3A 0.7A 15A 3A 3A 0.7A 15A 15A 6A 0.7A CURRENT RANGE 3 ~ 20A 0 ~ 6A 0.4 ~ 5A 0 ~ 1A 3 ~ 20A 0 ~ 5A 0.4 ~ 5A 0 ~ 1A 3 ~ 20A 0 ~ 20A 0.5 ~ 8A 0 ~ 1A RATED POWER 203.4W 202.5W 200W PEAK CURRENT Note.4 20A 7A 6A 1A 20A 6A 6A 1A 20A 20A 8A 1A OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.25 ~ 16.5V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +8,-10% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 24ms at full load VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 75% 75% 72% AC CURRENT (Typ.) 3.5A/115VAC 2A/230VAC INRUSH CURRENT (Typ.) COLD START 30A LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1: 5.75 ~ 6.75V CH2:17.25 ~ 20.25V CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of Q1,Q2 power transistor OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0~50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 5) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 160.6K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 215*115*50mm (L*W*H) 1.2Kg 12pcs/15.4Kg/0.92CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on 200W Quad Output with PFC Function Q P-200 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH1,2 can be adjustable from -5~+10% With power good and fail signal output(Optional) Built-in remote sense function for CH1,2 100% full load burn-in test CH4 can set to positive after consult us before delivery(Optional) Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty .. SPECIFICATION MODEL QP-200-3B QP-200-3C QP-200-3D OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 12V -12V 5V 3.3V 15V -15V 5V 3.3V 24V -12V RATED CURRENT 15A 15A 6A 0.7A 15A 15A 5A 0.7A 10A 15A 4A 0.7A CURRENT RANGE 3 ~ 20A 0 ~ 20A 0.5 ~ 8A 0 ~ 1A 3 ~ 20A 0 ~ 20A 0.5 ~ 6A 0 ~ 1A 3 ~ 15A 0 ~ 20A 0.4 ~ 5A 0 ~ 1A RATED POWER 204.9W 210W 203.9W PEAK CURRENT Note.4 20A 20A 8A 1A 20A 20A 7A 1A 20A 20A 6A 1A OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% +8,-10% 6.0% 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +10,-6% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 24ms at full load VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 72% 72% 74% AC CURRENT (Typ.) 3.5A/115VAC 2A/230VAC INRUSH CURRENT (Typ.) COLD START 30A LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of Q1,Q2 power transistor OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms -10 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0~50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 5) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 160.6K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 215*115*50mm (L*W*H) PACKING 1.2Kg 12pcs/15.4Kg/0.92CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on