125W Dual Output Switching Power Supply RD-125 series 9 - A - B > 8 > 8 8 ( ( 8 .1C & / * ( ( D ( ( ( , D E 8 ( ( ( & SPECIFICATION MODEL RD-125A RD-125B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 7.7A 7.7A 4.6A 4.6A CURRENT RANGE Note.6 2 ~ 15A 0.5 ~ 10A 2 ~ 10A 0.4 ~ 5A RATED POWER Note.6 130.9W 133.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 5.0% 7.0% 5.0% 7.0% LINE REGULATION Note.4 1.0% 2.0% 1.0% 2.0% LOAD REGULATION Note.5 3.0% 4.0% 3.0% 4.0% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 25ms/230VAC 30ms/115VAC at full load VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 82% 85% INPUT AC CURRENT (Typ.) 3A/115VAC 2A/230VAC INRUSH CURRENT (Typ.) COLD START 40A/230VAC LEAKAGE CURRENT <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1: 5.75 ~ 6.75V OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY 0.03%/ (0 ~ 50)on CH1 output TEMP. COEFFICIENT VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 7) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 232.4Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 199*98*38mm (L*W*H) 0.7Kg 20pcs/15Kg/0.8CUFT PACKING NOTE % & ( ) & *& & +, - ( ( + . ( & ( . ( / / 0 / 0 1 & 2 & ( 3 & 4 5 & , & & & 6 1 5 ( 0 7 0 & 2 6 * 1 8 9 ( & 1 :1 ( & < = 8 ->>&&& & . ( ( > 99 & 8 6 2 File Name:RD-125-SPEC 2015-07-08125W Dual Output Switching Power Supply RD-125 series 9 - A - B > 8 > 8 8 ( ( 8 .1C & / * ( ( D ( ( ( , D E 8 ( ( ( & SPECIFICATION MODEL RD-125-1224 RD-125-1248 RD-125-2448 OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2 DC VOLTAGE 12V 24V 12V 48V 24V 48V RATED CURRENT 3.7A 3.7A 2.3A 2.3A 2A 2A CURRENT RANGE Note.6 1 ~ 7A 0.4 ~ 5A 1 ~ 7A 0.2 ~ 2.5A 0.5 ~ 4A 0.2 ~ 2.5A RATED POWER Note.6 133.2W 138W 144W RIPPLE & NOISE (max.) Note.2 120mVp-p 200mVp-p 120mVp-p 240mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1: 11.4 ~ 13.2V CH1: 11.4 ~ 13.2V CH1: 22.8 ~ 26.4V VOLTAGE TOLERANCE Note.3 2.0% +8,-5% 2.0% +8,-5% 1.0% 4.0% LINE REGULATION Note.4 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% LOAD REGULATION Note.5 1.0% 5.0% 1.0% 5.0% 1.0% 3.0% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 25ms/230VAC 30ms/115VAC at full load VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 85% 86% 86% INPUT AC CURRENT (Typ.) 3A/115VAC 2A/230VAC INRUSH CURRENT (Typ.) COLD START 40A/230VAC LEAKAGE CURRENT <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1: 13.8 ~ 16.2V CH1: 13.8 ~ 16.2V CH1: 27.6 ~ 32.4V OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY 0.03%/ (0 ~ 50)on CH1 output TEMP. COEFFICIENT VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 7) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 218.2Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 199*98*38mm (L*W*H) 0.7Kg 20pcs/15Kg/0.8CUFT PACKING NOTE % & ( ) & *& & +, - ( ( + . ( & ( . ( / / 0 / 0 1 & 2 & ( 3 & 4 5 & , & & & 6 1 5 ( 0 7 0 & 2 6 * 1 8 9 ( & 1 :1 ( & < = 8 ->>&&& & . ( ( > 99 & 8 6 2 File Name:RD-125-SPEC 2015-07-08