400W Reliable Green Medical Power Supply RPS-400 series + + Type RPS-400 RPS-400-C RPS-400-TF RPS-400-SF Without Fan Watt 71K hours 28K hours - - - - - - With Fan Watt 98K hours 37K hours 69K hours 57K hours Type File Name:RPS-400-SPEC 2017-04-11400W Reliable Green Medical Power Supply RPS-400 s e ri e s SPECIFICATION MODEL RPS-400-12 RPS-400-15 RPS-400-27 RPS-400-36 RPS-400-18 RPS-400-24 RPS-400-48 DC VOLTAGE 12V 15V 18V 24V 27V 36V 48V 25CFM 33.3A 26.7A 22.3A 16.7A 14.9A 11.2A 8.4A CURRENT Convection 20.8A 16.7A 13.9A 10.5A 9.3A 7A 5.3A 25CFM 399.6W 400.5W 401.4W 400.8W 402.3W 403.2W 403.2W RATED POWER Convection 249.6W 250.5W 250.2W 252W 251.1W 252W 254.4W RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p OUTPUT 11.4~12.6V 14.3~15.8V 17.1~18.9V 22.8~25.2V 25.6 ~ 28.4V 34.2 ~37.8V 45.6 ~50.4V VOLTAGE ADJ. RANGE(main output ) VOLTAGE TOLERANCE Note.3 3.0% 3.0% 3.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION SETUP, RISE TIME 1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC/115VAC at full load VOLTAGE RANGE Note.4 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF>0.94/230VAC PF>0.98/115VAC at full load EFFICIENCY (Typ.) 91.5% 92% 93% 93% 93.5% 93.5% 94% INPUT 4.2A/115VAC 2.1A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT (max.) Note.5 Earth leakage current <160 A/264VAC , Touch current < 70 A/264VAC 105 ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed 16.5 ~ 19.5V 19.8 ~ 31.2V 26.4 ~ 31.2V 29.7 ~ 35.1V 39.6 ~ 46.8V 52.8 ~ 62.4V 13.2 ~ 15.6V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE 5Vsb : 5V 0.6A without fan, 1A with fan 25CFM 5V STANDBY Tolerance 2%, ripple : 120mVp-p(max.) 12V 0.5A for driving fan FAN SUPPLY Tolerance 10% FUNCTION Power on: PS-ON =H or > 2 ~ 5 PS-ON INPUT SIGNAL Power off: PS-ON =Lo or < 0 ~ 0.5 500ms>PG>10ms The TTL signal goes high with 10ms to 500ms delay after power set up POWER GOOD / POWER FAIL The TTL signal goes low at least 1ms before Vo below 90% of rated value WORKING TEMP. -30 ~ +70 (Refer toDerating Curv) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.6 4000 meters File Name:RPS-400-SPEC 2017-04-11