160W Triple Output Medical Type RPT-160 series %&& %( ) *&+ , , - .* , / ) - -0 ) 1 ) &+2 /- 1 .3 0 /- 45&+6 ) 7 5&+8 ) .3 0 / ) - - ) - RPT G 160A G: With 5Vsb & no load power consumption < 0.75 W Blank: Basic function (without 5Vsb) >1 8&8&% % B> 8&8&% % 6 SPECIFICATION MODEL RPT-160A RPT-160B RPT-160C RPT-160D OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 12V 24V RATED CURRENT (20.5CFM) 14A 5.5A 1A 14A 5A 1A 14A 3.6A 1A 11A 5A 1.2A CURRENT RANGE (convection) 0.6 ~ 9A 0.2 ~ 3.8A 0.1 ~ 0.6A 0.6 ~ 9A 0.2 ~ 3.4A 0.1 ~ 0.8A 0.6 ~ 9A 0.1 ~ 2.6A 0.1 ~ 0.8A 0.3 ~ 8A 0.2 ~ 2.6A 0.15 ~ 1A CURRENT RANGE (20.5CFM) 0.6 ~ 14A 0.2 ~ 5.5A 0.1 ~ 1A 0.6 ~ 14A 0.2 ~ 5A 0.1 ~ 1A 0.6 ~ 14A 0.1 ~ 3.6A 0.1 ~ 1A 0.3 ~ 11A 0.2 ~ 5A 0.15 ~ 1.2A RATED POWER (convection) Note.7 98.6W 98.4W 99W 98.2W RATED POWER (20.5CFM) Note.8 145W 146W 143W 147.8W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE CH1:5 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 5.0% -5,+7% 2.0% 5.0% -4,+5% 2.0% 4.0% 8.0% 2.0% 5.0% +7,-5% LINE REGULATION 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% LOAD REGULATION 1.5% 3.0% -5,+6% 1.5% 3.0% -4,+5% 2.0% 3.0% 8.0% 1.5% 3.0% -3,+4% SETUP, RISE TIME 1800ms, 30ms/230VAC 3500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC/115VAC at full load VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 84% 84% 83% 83% AC CURRENT (Typ.) 1.8A/115VAC 0.9A/230VAC INRUSH CURRENT (Typ.) COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT Note.9 Earth leakage current < 200A/264VAC , Touch current < 100 A/264VAC 105 ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover TSW1: Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE TSW2: Shut down o/p voltage, re-power on to recover 5VSB : 5V 0.6A without fan, 0.8A with fan 20.5CFM tolerance 2%, ripple : 50mVp-p(max.) 5V STANDBY (G model) Power on: PS-ON =H or > 2 ~ 5 Power off: PS-ON =Lo or < 0 ~ 0.5 FUNCTION PS-ON INPUT SIGNAL (G model) 500ms>PG>10ms PF>1ms POWER GOOD / POWER FAIL -20 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS ANSI/AAMI ES60601-1, TUV EN60601-1 approved ISOLATION LEVEL Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP SAFETY & WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH (Note 4) EMC EMISSION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 191.4K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 127*76.2*34.6mm (L*W*H) 0.33Kg 36pcs/12.9Kg/0.79CUFT PACKING %+ 1 9 - * &4 7 * / + NOTE *+ : *&,< / ) /- %* ) ) ) &+% (2 + + 9 7 + (+ 9 ) - ) ) / = + >, / /- 8& 8& ) % + 9 = / >, + ) >, 7 A>,B ) +C . / )))+ ) + 0 + < %7< * < / + 8+ D - / ) + + 2+ 9 ) 4 / 5 &+8 + 6+ 9 ) 4 / 5 &+6 + E+ 9 ) - D + File Name:RPT-160-SPEC 2015-08-064-3.5 160W Triple Output Medical Type RPT-160 series Mechanical Specification Unit:mm FAN AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment Mating Housing Terminal 20.5CFM min. 1 AC/L JST VHR JST SVH-21T-P1.1 2 No Pin SVR1 or equivalent or equivalent M1 3 AC/N HS1 CN3 1 DC Output Connector (CN2) : JST B8P-VH or equivalent 2 Pin No. Assignment Mating Housing Terminal 1 1,2,3,4 COM 2 HS2 3 5,6 CH1 FS1 JST VHR JST SVH-21T-P1.1 4 1 or equivalent or equivalent 7 CH2 5 CN1 2 6 HS3 8 CH3 3 7 8 FS2 Power Good Connector(CN3):JST B2B-XH or equivalent CN2 CN901 M2 Pin No. Status Mating Housing Terminal LED CN901 1 PG JST XHP JST SXH-001T-P0.6 1234 or equivalent or equivalent 2 GND 5 117 127 5VSB Connector(CN901) : JST B-XH or equivalent Pin No. Assignment Mating Housing Terminal PS/ON 1 PS/ON JST SXH-001T 5mA(max.) JST XHP 2,4 GND or equivalent or equivalent 3 5VSB GND 1.HS1,HS2,HS3 can not be shorted 2.M1 and M2 are Safety ground and should all be grounded. Block Diagram +5VSB fosc :100KHz DETECTION CIRCUIT RECTIFIERS POWER SWITCHING +5VSB & PWM CONTROL FILTER RECTIFIERS V3 & FILTER RECTIFIERS +V2 & FILTER RECTIFIERS EMI RECTIFIERS POWER +V1 I/P & & COM FILTER SWITCHING PFC FILTER PG PG DETECTION FG CIRCUIT O.L.P. CONTROL O.V.P. PS/ON PS/ON CONTROL Derating Curve Output Derating VS Input Voltage 100 100 With FAN 90 80 80 70 60 Without FAN 60 40 50 20 40 -20 0102030405060 70 (HORIZONTAL) 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:RPT-160-SPEC 2015-08-06 LOAD (%) 76.2 66.2 5 3 max. 34.6 5cm LOAD (%)