1500W Single Output Power Supply RSP-1500 series Users Manual B B = +2: B +2 B : 9+< ) B B +)9+< Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 % UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 CNS14336-1 < / %& / & = ) > & 7 / % / , 9 78 7 5 ( ( 7 A 7/ 7/ / 7/ 7 ( %& & ( ) *+,-.%& / ( & 0 ( 1 4 2 3 / 4 / / 5 6 / 4 / 4 78 7 4 5 ( 4 7 / 9 . + +-. +2. -:. 7 ( File Name:RSP-1500-SPEC 2021-09-151500W Single Output Power Supply RSP-1500 series SPECIFICATION MODEL RSP-1500-5 RSP-1500-12 RSP-1500-15 RSP-1500-24 RSP-1500-27 RSP-1500-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 240A 125A 100A 63A 56A 32A CURRENT RANGE 0 ~ 240A 0 ~ 125A 0 ~ 100A 0 ~ 63A 0 ~ 56A 0 ~ 32A RATED POWER 1200W 1500W 1500W 1512W 1512W 1536W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 10 ~ 13.5V 13.5 ~ 16.5V 20 ~ 26.4V 24 ~ 30V 43 ~ 56V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1500ms, 100ms at full load HOLD UP TIME (Typ.) 10ms at full load 14ms at full load 16ms at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC 0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 80% 87% 87% 90% 90% 91% AC CURRENT (Typ.) 17A/115VAC 8A/230VAC INRUSH CURRENT (Typ.) 30A/115VAC 60A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC 105 ~135% rated output power OVERLOAD Note.4 Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover 5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual. OUTPUT VOLTAGE PROGRAMMABLE(PV) CURRENT SHARING Up to 6000W or (3+1) units. Please refer to the Function Manual. AUXILIARY POWER 12V 0.1A(Only for Remote ON-OFF control) FUNCTION Please see the Function Manual. REMOTE ON-OFF CONTROL REMOTE SENSE Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual. ALARM SIGNAL OUTPUT Power OK signal. Please see the Function Manual. -20 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.05%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1,,BSMI CNS14336-1, AS/NZS62368.1 EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32) Class B EMC EMISSION Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-2 ----- Voltage Flicker BS EN/EN61000-3-3 ----- SAFETY & BS EN/EN55024, BS EN/EN61000-6-2, BSMI CNS13438 EMC (Note 5) Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 EMC IMMUNITY Surge BS EN/EN61000-4-5 Level 3, 2KV/Line-Earth Level 2, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% interruptions 250 periods MTBF 265.3K hrs min. Telcordia SR-332 (Bellcore) 90.3K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 278*127*83.5mm (L*W*H) 3.0Kg 4pcs/13Kg/1.19CUFT PACKING % 87 + .%& 4 + NOTE C + 3=D ( +E ( ( ( C -2 A 4 ( / 1 / ( ( ( 6 % 03& 5 2+ B , ( 1 6 03& / ( 03& 4 F03G ( H 9 /