2400W Power Supply with Single Output RSP-2400 series C 0 C Bauart gepruft Sicherheit 93 C 99.3 C B. = > egelma ge od os be wac g www.tuv.com . C C . = > ID 2000000000 9 1 3 4 51 ( 6 - * . & * + + ) < 6 * * + 1 6 * 9 0 = A > ( < < % & 2 2 </ * & - <6 & <6 6 * ( <6 + & * < * , 2 , - . /0 * & 1 ) 2 . % 3 4 51 6 * & & 2 ) & & & & . & & + + 2 & 7 2 8 * 79 . 6 7 , - 6 & 6 & * + * 6 + * *7 6 *7 < < 7 2 7 . < 6 * = 5 5 35> < 2 * File Name:RSP-2400-SPEC 2016-07-262400W Power Supply with Single Output RSP-2400 series SPECIFICATION MODEL RSP-2400-12 RSP-2400-24 RSP-2400-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 166.7A 100A 50A CURRENT RANGE 0 ~ 166.7A 0 ~ 100A 0 ~ 50A RATED POWER 2000.4W 2400W 2400W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 22 ~ 28V 43 ~ 56V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 80ms at full load HOLD UP TIME (Typ.) 12ms at full load VOLTAGE RANGE 180 ~ 264VAC 254 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC at full load INPUT EFFICIENCY (Typ.) 88% 90.5% 91.5% AC CURRENT (Typ.) 15.5A/180VAC 12A/230VAC INRUSH CURRENT (Typ.) 60A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC 100 ~ 112% rated output power OVERLOAD (OLP) User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover 13.8 ~ 16.8V 28.8 ~ 33.6V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE 2.4 ~ 13.2V 4.8 ~ 28V 9.6 ~ 56V OUTPUT VOLTAGE PROGRAMMABLE(PV) Please refer to the Function Manual. CURRENT SHARING Up to 7200W or (2+1) units. Please refer to the Function Manual. 12V 0.1A(Only for Remote ON-OFF control) FUNCTION AUXILIARY POWER Please refer to the Function Manual REMOTE ON-OFF CONTROL REMOTE SENSE Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual. ALARM SIGNAL OUTPUT Power OK signal. Please refer to the Function Manual -20 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes VIBRATION UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55022 (CISPR22) / EN55011 (CISPR11) Class B Radiated EN55022 (CISPR22) / EN55011 (CISPR11) Class A EMC EMISSION Harmonic Current EN61000-3-2 ----- Voltage Flicker EN61000-3-3 ----- SAFETY & EN55024 , EN61204-3, EN61000-6-2 EMC Parameter Standard Test Level / Note (Note 4) ESD EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact Radiated EN61000-4-3 Level 3 EFT / Burst EN61000-4-4 Level 3 EMC IMMUNITY Surge EN61000-4-5 Level 3, 2KV/Line-Earth Level 2, 1KV/Line-Line Conducted EN61000-4-6 Level 3 Magnetic Field EN61000-4-8 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, Voltage Dips and Interruptions EN61000-4-11 >95% interruptions 250 periods MTBF 234.1K hrs min. Telcordia SR-332 (Bellcore) 83.9K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 278*177.8*63.5mm (L*W*H) 3.3Kg 4pcs/14.2Kg/1.81CUFT PACKING . 1 <% & & B 51 7 & & & . NOTE . D & E + &2 & + * F 2 & 2 & 2 . D 9 . B. % & 7 * & & * . . % 2 & & 2 2 + & . 1 + : & + * 9 CB 2 8 . % + & 6 . *& 2 7 G * 2 .H = 6 + 222. 2 . > File Name:RSP-2400-SPEC 2016-07-26