10000W Single Output Power Supply RS T-1 0 00 0 s eri es Bau ar t ge p r uf t Si che rh ei t eg el m a ge od o s b e w a c g ww w. tuv.com ID 20 00 00 00 00 Features Applications 3 3-wire / 196~305VAC or 3 4-wire / Y 340~530VAC Industrial control equipments wide input range Automation equipments Built-in active PFC function Laser engravers High efficiency up to 91% Telecommunication systems Protections: Short circuit / Overload / Over voltage / Over temperature / Fan fail Forced air cooling by built-in fan with speed control function Output voltage can be trimmed between 20~120% by 1~6VDC external control signal Output current can be trimmed between 20~100% by 1~5VDC external control signal Current sharing up to 2 units Alarm signal output (relay contact and open collector signal): AC fail, DC OK, fan fail, OTP Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON/OFF control Built-in remote sense function 5 years warranty Description RST-10000 is one 10000W single output enclosed type AC/DC power supply series. This series accepts the wide range 3-phase AC input (3 3-wire / 196~305VAC or 3 4-wire / Y 340~530VAC) and supplies 24VDC, 36VDC and 48VDC at the output. RST-10000 particularly provides the wide range adjustment function for output voltage and current by means of an external control signal moreover, RST-10000 offers two overload protection mechanisms, the continuous constant current limiting mode and the constant current limiting with delay shutdown after 5 seconds mode, well providing the flexibility for high power system design. RST-10000 has the built-in active PFC function and the working efficiency is high up to 91%. With the built- in fan, the entire series can supply the full load output under 50 ambient temperature. The parallel function is built to transmit an even higher power with up to 2 units. Other functions include the remote sense function, the 12V/0.1A auxiliary power, the alarm signal output (both relay contact and open collector signal) for AC fail, DC OK, fan fail, over temperature protection, etc. RST-10000 series acquires the major global safety regulation certificates. Model Encoding RST - 10000- 24 Output voltage Output wattage Series name File Name:RST-10000-SPEC 2015-04-0910000W Single Output Power Supply RS T-1 00 0 0 s eri es SPECIFICATION MODEL RST-10000-24 RST-10000-36 RST-10000-48 DC VOLTAGE 24V 36V 48V RATED CURRENT 400A 276A 210A CURRENT RANGE 0 ~ 400A 0 ~ 276A 0 ~ 210A RATED POWER 9600W 9936W 10080W RIPPLE & NOISE (max.) Note.2 150mVp-p 200mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE Note.4 23.5 ~ 28.8V 35 ~ 43.2V 47 ~ 57.6V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% SETUP, RISE TIME 2200ms, 80ms at full load HOLD UP TIME (Typ.) 20ms / 230VAC at 75% load 14ms / 230VAC at full load VOLTAGE RANGE 3 3-wire / 196 ~ 305VAC or 3 4-wire / Y 340 ~ 530VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC(400VAC) at full load INPUT EFFICIENCY (Typ.) 89% 90% 91% AC CURRENT (Typ.) 30A/230VAC(3 3-wire / ) 18A/400VAC(3 4-wire / Y) INRUSH CURRENT (Typ.) 150A/230VAC(3 3-wire / ) 100A/400VAC(3 4-wire / Y) LEAKAGE CURRENT <7mA /305VAC(Y 530VAC) 100 ~ 112% rated output power OVERLOAD User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover PROTECTION 30 ~ 33.6V 45 ~ 50.4V 60 ~ 67.2V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down 12V 0.1A(Only for Remote ON/OFF control) AUXILIARY POWER(AUX) Please refer to the Function Manual REMOTE ON/OFF CONTROL ALARM SIGNAL OUTPUT Please refer to the Function Manual FUNCTION OUTPUT VOLTAGE TRIMMING Adjustment of output voltage is allowable between 20 ~ 120% by 1 ~ 6VDC external control signal OUTPUT CURRENT TRIMMING Adjustment of output current is allowable between 20 ~ 100% by 1 ~ 5VDC external control signal CURRENT SHARING Please refer to the Function Manual -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE Note.5 I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE Note.5 I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3 (Note 6) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 18.7K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 540*424*83.5mm (L*W*H) 23.5Kg 1pcs/23.5Kg/2.45CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC(Y 400VAC) input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Adjusted through potentiometer. 5. During withstandards voltage and isolation resistance testing, the screw A shall be temporarily removed, and shall be istalled back after the testing. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on