150W Single Output with PFC Function SP-150 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . com ID 2000000000 SPECIFICATION MODEL SP-150-3.3 SP-150-5 SP-150-7.5 SP-150-12 SP-150-13.5 SP-150-15 SP-150-24 SP-150-27 SP-150-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 30A 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A CURRENT RANGE 0 ~ 30A 0 ~ 30A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 6.3A 0 ~ 5.6A 0 ~ 3.2A RATED POWER 99W 150W 150W 150W 151.2W 150W 150W 151.2W 153.6W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 700ms, 40ms at full load HOLD UP TIME (Typ.) 20ms at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC PF>0.97/115VAC at full load INPUT EFFICIENCY (Typ.) 73% 77.5% 81% 84% 84% 85% 85% 85% 85% 2.5A/115VAC 1.2A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 45A/230VAC LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.2V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE FUNCTION REMOTE CONTROL(OPTION) CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF -10 ~ +55 (Refer to output load derating curve) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY -20 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.05%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) Compliance to EN55032 (CISPR32) Class B,EN61000-3-2,-3 EMC EMISSION EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, EN55024, light industry level, criteria A MTBF 191.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 199*99*50mm (L*W*H) PACKING 0.76Kg 20pcs/16.4Kg/1.28CUFT NOTE File Name:SP-150-SPEC 2017-07-14150W Single Output with PFC Function SP-150 series Mechanical Specification Case No. 916A Unit:mm 199 20 35 133 25 117 70 65 I/P L1 CN1 1 R.C. 2 +V ADJ. LED 7 6 5 2-M4 L=5mm 4 18CFM FAN 5-M3 L=3mm 3 2 1 Terminal Pin No. Assignment 15 Pin No. Assignment Pin No. Assignment 142 1 AC/L 4,5 DC OUTPUT -V 25 2 AC/N 6,7 DC OUTPUT +V 3 FG 11 max. Remote ON/OFF(CN1):JST S2B-XH or equivalent(optional) Pin No. Assignment Mating Housing Terminal 1 RC+ JST XHP JST SXH-001T-P0.6 or equivalent or equivalent 2 RC- 6-M4 L=6mm PFC fosc : 67KHz Block Diagram PWM fosc : 134KHz EMI FILTER RECTIFIERS POWER PFC +V I/P & & SWITCHING CIRCUIT -V RECTIFIERS FILTER CONSTANT CURRENT LIMITING & FG DETECTION O.L.P. PWM & PFC CIRCUIT ACTIVE CONTROL START O.V.P. CIRCUIT O.T.P. REMOTE CN1 CONTROL Derating Curve Output Derating VS Input Voltage SP-150-12~48 100 100 SP-150-3.3~7.5 (With 18CFM FAN) 90 80 80 70 60 SP-150-3.3 SP-150-5 SP-150-7.5 60 40 50 20 40 -10 0 10 20 30 40 45 50 (HORIZONTAL) 85 100 115 135 155 230 264 -10 0 10 20 35 45 50 55 (VERTICAL) AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:SP-150-SPEC 2017-07-14 8 9.5 LOAD (%) 16 25 49.5 12.5 25 51 38 10 50 79 LOAD (%) 99 119 15 mm