75W Triple Output with PFC Function TP-75 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Low profile: 33mm thickness LED indicator for power on Cooling by free air convection Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty SPECIFICATION MODEL TP-75A TP-75B TP-75C OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 7A 3A 0.6A 7A 3A 0.4A 6A 2.5A 0.5A CURRENT RANGE 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 3A 0 ~ 0.6A RATED POWER 74W 75.8W 75W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% SETUP, RISE TIME 800ms, 60ms at full load HOLD TIME (Typ.) 36ms at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 70% AC CURRENT (Typ.) 1.5A/115VAC 0.8A/115VAC INRUSH CURRENT (Typ.) COLD START 20A/230VAC LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 6.75V on +5V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT -20 ~ +85 , 10 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 Approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, EN55024, Light industry level, criteria A MTBF 198.4K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 179*99*33mm (L*W*H) 0.65Kg 20pcs/12.7Kg/0.64CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:TP-75-SPEC 2005-09-1375W Triple Output with PFC Function TP-75 s e ri e s Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Low profile: 33mm thickness LED indicator for power on Cooling by free air convection Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty SPECIFICATION MODEL TP-75D TP-7503 OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 24V 12V 5V 3.3V 12V RATED CURRENT 7A 1.5A 0.4A 9A 8A 0.3A CURRENT RANGE 1.5 ~ 10A 0.2 ~ 2.5A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 8A 0 ~ 0.6A RATED POWER 75.8W 75W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 120mVp-p 100mVp-p 50mVp-p 120mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 3.0% 4.0% 8.0% 3.0% 4.0% 8.0% SETUP, RISE TIME 800ms, 60ms at full load HOLD TIME (Typ.) 36ms at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 70% AC CURRENT 1.5A/115VAC 0.8A/115VAC INRUSH CURRENT (max.) COLD START 20A/230VAC LEAKAGE CURRENT <2mA / 240VAC 105 ~ 150% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 6.75V on +5V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 Approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B EMC EMI CONDUCTION & RADIATION (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, EN55024, Light industry level, criteria A MTBF 198.4K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 179*99*33mm (L*W*H) 0.65Kg 20pcs/12.7Kg/0.64CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:TP-75-SPEC 2005-09-13