400W True Sine Wave DC-AC Power Inverter TS-400 series ( * % & %&(( ( ) & %&(( ) * + + & + & + & + , + & - * 0 . E13 TPTC004 IEC62368-1 SPECIFICATION (for 212/224/248 only) TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248 MODEL NO. = A, E, F = B, C, D RATED POWER 400W MAXIMUM OUTPUT POWER 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) Factory setting set at 110VAC Factory setting set at 230VAC AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W OUTPUT FREQUENCY Note.6 600.1Hz 50/60Hz selectable by setting button 500.1Hz 50/60Hz selectable by setting button WAVEFORM Note.2 True sine wave (THD<3%) AC REGULATION Note.2 3.0% at rated input voltage FRONT PANEL INDICATOR Operation status Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC DC CURRENT (Typ.) 40A 20A 10A 40A 20A 10A INPUT NO LOAD CURRENT DRAW (Typ.) 1.25A 0.63A 0.32A 1.25A 0.63A 0.32A OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.1 84.5% 86% 87% 86% 87.5% 88.5% BATTERY TYPES Open & sealed Lead Acid FUSE 40A*2 40A*1 20A*1 40A*2 40A*1 20A*1 BATTERY BAT. LOW ALARM 11.34% 22.54% 454% 11.34% 22.54% 454% INPUT 10.54% 214% 424% 10.54% 214% 424% BAT. LOW SHUTDOWN PROTECTION By internal fuse open BAT. POLARITY 75 5 70 5 85 5 75 5 70 5 85 5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover by internal RTH1 detect power transistor OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OUTPUT PROTECTION 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover GFCI PROCTECTION Optional (Only type F) None FUNCTION REMOTE CONTROL Open : Normal work Short : Remote off WORKING TEMP. -10 ~ +40 100% load +60 50% load 20% ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT o -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes IEC62368-1 CB, EAC TP TC 004 approved, EAC TP TC 004 approved, Design refer to UL458, SAFETY STANDARDS BS EN/EN62368-1 Design refer to BS EN/EN62368-1 WITHSTAND VOLTAGE Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC SAFETY & Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25/ 70% RH ISOLATION RESISTANCE EMC Compliance to BS EN/EN55032 class A, 72/ 245/ CEE, EMC EMISSION Compliance to FCC class A, EAC TP TC 020 95/ 54/ CE, E-Mark, EAC TP TC 020 Compliance to EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,8, EAC TP TC 020 MTBF 104.7K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 205*158*67mm (L*W*H) 1.73Kg 6pcs/11.4Kg/1.55CUFT PACKING 1 2 / . 1 3+453+ 43 NOTE 4 -6 / 7 . 1 3+453+ 43 / *114+414 38147+44713817 +47 43 7 / . 4 / / +1 +1 4 5 5 ( 5 9 ) : / ( . 400W True Sine Wave DC-AC Power Inverter TS-400 series TS 400 112 A A :TYPE A OUTLET B :TYPE B OUTLET 12:12VDC True sine wave inverter C :TYPE C OUTLET Bat. Voltage: 24:24VDC D :TYPE D OUTLET 48:48VDC E :TYPE E OUTLET 1:110VAC F :TYPE F OUTLET Output: O/P Wattage:400W 2:230VAC AC Output Socket (optional) MODEL NO. TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248 Socket type TYPE-A TYPE-E TYPE-F TYPE-B TYPE-C TYPE-D Standard Optional Optional Standard Optional Optional USA JAPAN GFCI(60Hz) EUROPE AUSTRALIA U.K Country None EEE13 13 13 Certificate Mechanical Specification Derating Curve Unit:mm R.C Connector : JST B-XH or equivalent Open Normal work 100 Short Remote off 25.32 80 60 50 40 20 11 -10 0 10 20 30 40 50 60 70 8.9 Air flow (HORIZONTAL) direction ENVIRONMENT TEMPERATURE () 9 AC OUTPUT Status Setting Type-A AC OUTPUT Status Setting Type-B 147 158 File Name:TS-400-SPEC 2021-06-28 7 18 12 10.7 120 42.5 67 205 LOAD (%) Reverse Polarity ON Will Damage The Unit. OFF Chassis Ground R.C