750W Slim Type with PFC Switching Supply UHP-750 series Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 EN62368-1 UL62368-1 IEC62368-1 % && ( & ) * +& ,- &) ( & & .( / 0% ( -~ +1 2 ) Industrial automation machinery 0 & + ( 3/ Industrial control system 3/ / ) 3/ Mechanical and electrical equipment 4 35 Electronic instruments, equipment 3 ) ( ( 6 or apparatus 4 Household appliances & UHP-750 series is a 750W single-output slim type power supply with 41mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 12V, 24V,36V and 48V. In addition to the high efficiency up to 95%, that the whole series operates from -30~ 70 under air convection without fan. UHP-750 has the complete protection functions and 5G anti-vibration capability It is complied with the international safety regulations such as TUV EN62368-1 and UL62368-1. and the design refers to EN61558-1 and EN60335-1. UHP-750 series serves as a high performance power supply solution for various industrial applications. 3( ( , ) , , , , 7 ) & File Name:UHP-750-SPEC 2019-02-11750W Slim Type with PFC Switching Supply UHP-750 series SPECIFICATION MODEL UHP-750-12 UHP-750-24 UHP-750-36 UHP-750-48 12V 36V 48V DC VOLTAGE 24V RATED CURRENT 60A 31.3A 20.9A 15.7A RATED POWER(convection) 720W 752.4W 753.6W 751.2W RIPPLE & NOISE (max.) Note.2 150mVp-p 250mVp-p 250mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 12~14.4V 24~28.8V 36~43.2V 48~57.6V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% LINE REGULATION 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load HOLD UP TIME (Typ.) 12ms/230VAC 12ms/115VAC VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF0.95/230VAC PF 0.99/115VAC at full load INPUT 95% 95% EFFICIENCY (Typ.) 93.5% 95% AC CURRENT (Typ.) 7.5A/115VAC 3.8A/230VAC INRUSH CURRENT (Typ.) Cold start 20A/115VAC 40A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC 105~125% rated output power OVERLOAD Protection type: Hiccup mode, recovers automatically after fault condition is removed PROTECTION 14.5 ~ 16V 29 ~ 33V 43.5 ~ 49V 59 ~ 66V OVER VOLTAGE Protection type: Shut down O/P voltage, re-power on to recover OVER TEMPERATURE Protection type: Shut down O/P voltage, recovers automatically after temperature goes down Contact rating(max.): 30Vdc/1A resistive load FUNCTION DC-OK SIGNAL WORKING TEMP. -30 ~ +70(Refer to Derating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 10 ~ 95% RH non-condensing STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS UL62368-1,TUV EN62368-1, EAC TP TC 004 approved Design refer to EN61558-1, EN60335-1 WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25/ 70%RH EMC Parameter Standard Test Level / Note (Note.5) Conducted EN55032 (CISPR32) Class B Radiated EN55032 (CISPR32) Class B EMC EMISSION Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 ----- EN55024 , EN61000-6-2 Parameter Standard Test Level / Note ESD EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact Radiated EN61000-4-3 Level 3 EFT / Burst EN61000-4-4 Level 3 EMC IMMUNITY Surge EN61000-6-2 2KV/Line-Line 4KV/Line-Earth Conducted EN61000-4-6 Level 3 Magnetic Field EN61000-4-8 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, Voltage Dips and Interruptions EN61000-4-11 >95% interruptions 250 periods MTBF 279.97K hrs min. Telcordia SR-332 (Bellcore) 104.86K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 237*100*41mm (L*W*H) 1.4kg 10pcs/15kg/0.8CUFT PACKING 6 - & 38 & & ,- ( 9 : 6 6 7 & & <= : + : (& ) > & + 6 ( 1( 6 NOTE 6 8 includes set up tolerance, )( )( 6 6 4 ) : ( ( / ) &6 0 & + 2 + derating curve &6 6 8+ &( & & + + : & ( 6 - + & & : ( : ( ) + ( A + + 2 &&6 8+ ( (& : + & & / &6 % )( + + & & &9 & B C & ) &( &6D & / : + 6 6 6 8+ : ) 6 + && & + & ) ( + )+ + 6 File Name:UHP-750-SPEC 2019-02-11