EAP Cat v2 2013 Oct17 Layout 1 30/10/2013 17:04 Page 54 Portable Fume Extraction Systems BVX-100 Benchtop Single User BVX-200 Two Stations Portable Arm/Plenum System Filter Unit w Two station arm design for w Quiet unit dynamic fume extraction w Portable, single user unit w Quiet brushless motor w No external ducting or w Complete portability, placed compressor needed under or next to the bench-top 3 w Powerful 85m /hr-airflow rate w Fitted with 2x 50mm (2 ) w Unit easily fits on and under any workbench arms or 1x 63mm (2.5 ) arm w Innovative adaptor transforms the plenum into an arm w Main filter has a HEPA efficiency of 99.97% at 0.3 micron, and an activated carbon filter to remove additional gases w Immediate extraction of fumes, particles and vapors w Deep-bed gas filter for high capacity of gas filtration, such as w Two filtration configurations: heavy soldering and light dust or cleaning with solvents or conformal coatings light duty organic solvent and adhesive applications w Audible alarm informs operators when filters need replacing w Bi-colored LED light indicates when the filters are blocked and require replacing w Easy access bench-top on/off remote switch Part No. Description Part No. Description BVX-101 Bench-Top, single user arm/plenum system, BVX-201 Filter unit for 2 stations, Pre-HEPA-Gas Pre-HEPA-Gas BVX-203 Filter unit for 2 stations, Pre-Deep Bed Gas BVX-103 Bench-Top, single user arm/plenum system, Pre-Gas BVX-201-KIT Filter unit with 2 BVX-ARML, Pre-HEPA-Gas BVX-201-KIT1 Filter unit with 2 BVX-ARM-K1, Pre-HEPA-Gas Filters FG-BVX Deep Bed Gas Filter Filters FM-BVX Main Filter (Combined HEPA/Gas) FP-BVX200 Pre-Filter (Pack of 5) FP-BVX Pre-Filter (Pack of 5) FM-BVX200 Main Filter HEPA Carbon FG-BVX200 Deep Bed Gas Filter Accessories Accessories BVX-ADT Replacement Arm-To-Plenum Adaptor BVX-ARM-K1 BVX-ARM 760mm (30 ) with 1.8m (6 ) long hose & BVX-IADT Inverted Arm Adaptor, ESD Safe table bracket w/ C-clamps BVX-BCK Under Bench Mounting Bracket BVX-ARM-K2 BVX-ARM 760mm (30 ) & table bracket w/ C-clamps BVX-CH01 Connection hose, 50mm (2 ) diameter, 1.8m (6 ) long BVX-ARM Arm flexible ESD safe, 760mm (30 ) BVX-TB01 Table bracket with 2 C-clamps BVX-ARML Arm flexible ESD safe, 1.5m (59 ) with arm clip BVX-TB01 Table bracket with 2 C-clamps BVX-CH01 Connection hose, 50mm (2 ) diameter, 1.8m (6 ) BVX-CH02 Connection hose, 50mm (2 ) diameter, 3.6m (12 ) RPS-1 Remote power switch (for use with BVX-200 only) Technical Specifications TechnBicVaXl -S1p0e0c i f i c a t i o n s BVX-200 Static Pressure (suction force)Static P1r2e5s0s uPrae ((5uWctCio)n force) 850 Pa (3.5 WC) 3 3 Fan Capacity Fan Ca1p1a0cmity/h (65 cfm) 250m /h (150 cfm) 3 3 Flow Rate (with filter) Flow R8a5tem (w/hit h(5 f0il tcefrm) ) 2 x 75m /h (45 cfm) Air Inlets/Number of Stations Air Inle1ts/Number of Stations 2 HEPA Efficiency HEPA E9f9fi.c9i7e%nc yat 0.3 micron 99.97% at 0.3 micron Noise Level Noise L<e 5v5e ldb A < 55 db A Dimensions (W x D x H) Dimens3i0o0nms m(W x x 2 D30 xm Hm) x 290mm 508mm x 254mm x 388mm (11.8 x 9.1 x 11.4 ) (20 x 10 x 15.3 ) Weight Weight9kg (20lbs) 9kg (20lbs) Voltage Voltage100-240 VAC 100-240 VAC Frequency Freque5n0c-y60 Hz 50-60 Hz Filters are easy to Power Power 85 watt 85 watt remove and replace. Certification CertificUatLio, nCSA, CE UL, CSA, CE Max duct run 3.6 m (12 ) Max duct run 54 www.metcal.com www.metcal.comEAP Cat v2 2013 Oct17 Layout 1 30/10/2013 17:04 Page 55 Multi-function Extraction Systems MFX-2200C Particle Fume MFX-2200G Gas Fume Extraction Extraction System System The MFX-2200G Fume Extraction The multi-user MFX-2200C Fume Extraction System provides System has been specifically designed the ultimate performance in a compact size that easily fits under for the removal of gases and vapors most workbenches. It is ideal for removing solder fumes and from a range of heavy duty bench-top filtering laser fumes. applications, including solvent cleaning, Key Features &Benefits gluing/bonding and conformal coatings. w Excellent air flow performance Key Features &Benefits w Large, pleated pre-filter w High capacity gas filter cartridge ensures a long dwell-time of w HEPA filter rating of 99.97% at 0.3 micron the gases inside the filter media w Casters as standard w Large, pleated pre-filter w Dust filter seal keeps filter housing clean w Casters as standard w Minimum operating noise w Minimum operating noise w Compact size, unit fits under most workbenches w Provides air flow for two exhaust cabinets w Connects up to 4 Omniflex arms with rectangular nozzle w The unit lid features 100mm (4 ) and 63mm (2.5 ) air inlet (EA1122) or large hood (EA1126) flanges suitable for the connection of exhaust arms or cabinets w Connects up to 8 BVX arms or 8 Omniflex arms with tapered nozzle (EA1124) Part No. Description MFX-2200G-A Gas Fume Extraction System Analog 110V Part No. Description MFX-2206G-A Gas Fume Extraction System Analog 230V MFX-2200C-A Particle Fume Extraction System Analog 110V MFX-2200G-D Gas Fume Extraction System Digital 110V MFX-2206C-A Particle Fume Extraction System Analog 230V MFX-2206G-D Gas Fume Extraction System Digital 230V MFX-2200C-D Particle Fume Extraction System Digital 110V Filters MFX-2206C-D Particle Fume Extraction System Digital 230V FIL22P040 Prefilter Pleated 85% Efficiency Filters FIL22G010 Gas Filter Cartridge 11kg (25lbs) FIL22P030 Prefilter Pleated 60% Efficiency (Pack of 2) FIL22G020 Carbon Refill Kit 11kg (25lbs) FIL22H070 Combination Filter HEPA/Carbon Accessories Accessories AC2202 Top cover with 4 air inlets 63mm (2.5 ) AC2204 Top cover with 2 air inlets 100mm (4 ) and 2 air inlets 63mm (2.5 ) Technical Specifications 110V Units 230V Units Technical Specifications Air Inlet Openings 2x4 & 2x2.5 2x100mm & 110V Units 230V Units 2x63mm Air Inlet Openings 4 x 2.5 4 x 63mm 3 Fan Capacity 600 cfm 900m /h 3 Fan Capacity 600 cfm 900m /h 3 Flow Rate 350 cfm 550m /h 3 Flow Rate 400 cfm 600m /h Static Pressure 4.5 WC Max 1075 Pa HEPA Efficiency 99.97% at 0.3 micron 99.97% at 0.3 micron Power Supply 100-120VAC, 60Hz 220-240VAC, 50Hz Static Pressure 4.5 WC Max 1075 Pa Power 400 Watt 400 Watt Power Supply 100-120VAC, 60Hz 220-240VAC, 50Hz Noise Level 58 dbA 58 dbA Power 400 Watt 400 Watt Dimensions (W x D x H) 17.7 x 20.7 x 26.4 450 x 525 x 670mm Noise Level 58 dbA 58 dbA Weight 115 lbs 52 Kg Dimensions (W x D x H) 17.7 x 20.7 x 26.4 450 x 525 x 670mm Certification UL, CSA CE Weight 93 lbs 43 Kg Max duct run 100 30 m Certification UL, CSA CE Max duct run 100 30 m PlePaletaetedd P Prree--FFiilltteerr Controls and Filter Monitor Gas Filter Gas Filter 11 kg (25 Ibs) 11kg (25 lbs) w Unit On/Off Switch with power indicator Activated CarbonActivated Carbon After After-Filter w Thermal overload protection Filter w Analog models with filter status gauge w Digital models with filter status indicator lights and other control options 55 www.metcal.com www.metcal.com