MCP9501/2/3/4 Temperature Switch with Selectable Hysteresis Features Description Factory Set Temperature Switch Microchip Technologys MCP9501/2/3/4 family devices are temperature switches with 1C (typical) accurate Available Temperature Switch Thresholds: factory set output thresholds. These devices are ideal for -T =-35C, -25C, -15C, -5C, +5C, SET high-power supply systems where an overtemperature +15C, +25C, +35C, +45C, +55C, +65C, protection circuit is needed. These devices do not +75C, +85C, +95C, +105C, +115C, require external components, consume 25 A (typical), +125C and the factory set thresholds provide simplicity. Wide Operating Voltage Range: 2.7V to 5.5V In addition, this family of devices provides Low Supply Current: 25 A (typical) user-selectable +2C and +10C (typical) switch hyster- Qualification: AEC-Q100 Rev. G, Grade 1 esis, and various output configurations. The MCP9501/2 (-40C to +125C) outputs switch for rising temperatures, while the Temperature Switch Accuracy: MCP9503/4 devices switch for falling temperatures, with - 1C (typical) the relative hysteresis at the set thresholds. This family of devices is also available with an active-high, push-pull - 4C (maximum) between -15C to +75C output (MCP9502/4) and an active-low, open-drain - 6C (maximum) between -40C to +125C output (MCP9501/3). The push-pull output is ideal for a Switch Threshold Options (Hot/Cold): microcontroller interface, while the open-drain output - Rising temperature: MCP9501/2 (Hot option) can be used for level shifting, wired-OR configuration or - Falling temperature: MCP9503/4 (Cold option) as a heater on/off switch. Output Configuration Options: The MCP9501/2/3/4 devices operate from a 2.7V to 5.5V - Active-low, open-drain output: MCP9501/3 supply. This family is available with the space-saving 5-lead SOT-23 package. - Uses external pull-up resistor - Active-high, push-pull output: MCP9502/4 Package Types User-Selectable Hysteresis: +2C or +10C (typical) MCP9501/2/3/4 5-Lead SOT-23 Package 5-Lead SOT-23 Applications Power Supply Critical Temperature Shutdown GND 1 5 Output Temperature Alarm GND 2 Thermostat Control 4 V HYST 3 DD Fan Control Base Stations Automotive Typical Performance 40% T = -35C to +125C A 35% V = 4.1V DD 32 Units 30% 25% 20% 15% 10% 5% 0% -4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0 3.0 4.0 Temperature Accuracy (C) 2011-2016 Microchip Technology Inc. DS20002268B-page 1 Occurrences MCP9501/2/3/4 OUTPUT FUNCTIONAL DESCRIPTION MCP9501, Hot Option (Open-Drain, Active-Low) Hysteresis V Output Note: Available temperature thresholds for Option P or for rising temperature only: +5C, +15C, +25C, +35C, +45C, +55C, +65C, +75C, +85C, +95C, +105C, +115C, +125. Temperature COLD HOT T T HYST SET MCP9502, Hot Option (Push-Pull, Active-High) Hysteresis V Output Note: Available temperature thresholds for Option P or for rising temperature only: +5C, +15C, +25C, +35C, +45C, +55C, +65C, +75C, +85C, +95C, +105C, +115C, +125. Temperature T T COLD HYST SET HOT MCP9503, Cold Option (Open-Drain, Active-Low) Hysteresis V Output Note: Available temperature thresholds for Option P or for rising temperature only: +5C, +15C, +25C. Available temperature thresholds for Option N or for falling temperature only: -35C, -25C, -15C, -5C. Temperature T T COLD SET HYST HOT MCP9504, Cold-Option (Push-Pull, Active-High) Hysteresis V Note: Available temperature thresholds for Output Option P or for rising temperature only: +5C, +15C, +25C. Available temperature thresholds for Option N or for falling temperature only: -35C, -25C, -15C, -5C. Contact Microchip for all other threshold options. Temperature COLD T T HOT SET HYST DS20002268B-page 2 2011-2016 Microchip Technology Inc.