REVISION PROPRIETARY INFORMATION: REV DESCRIPTION DATE AUTHOR PROPRIETARY OF ROVING NETWORKS ANY REPRODUCTION, DISCLOSURE OR USE OF THIS DRAWING, IN WHOLE OR IN PART, IS HEREBY A INITIAL RELEASE, RFS.2474 1/18/06 MC PROHIBITED EXCEPT AS SPECIFIED IN WRITING BY ROVING NETWORKS B UPDATE DWG O/P CONNECTOR, RFS.271 03/05/08 MC 1. NOTES: DIMENSIONS ARE IN MM UNLESS SPECIFIED OTHERWISE. 2. ELECTRICAL SPECIFICATIONS: INPUT VOLTAGE: 90 VAC TO 264 VAC INPUT CURRENT: < 0.5 A RMS AT 90 VAC INPUT INPUT FREQUENCY: 47 - 63 HZ OUTPUT VOLTAGE / CURRENT: + 5 VDC AT 0 - 1000 mA OUTPUT CURRENT : NO LOAD TO FULL LOAD,NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 5 WATTS MAX OUTPUT RIPPLE (PEAK TO PEAK): < 100 mV P-P OUTPUT REGULATION (LINE/LOAD): + 5 % FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR LINE REGULATION: + 2 % MAX AT FULL LOAD TURN ON/ TURN OFF OVERSHOOT: 4% MAX 500uS MAX RECOVERY TIME FOR 25% STEP LOAD TURN-ON DELAY: 1000 mSEC MAX HOLD-UP TIME: 16 mSEC MIN AT NOMINAL INPUT AND FULL LOAD INRUSH CURRENT: 20 A MAX AT COLD START N.A. EFFICIENCY: 60 % TYPICAL. SWITCHING FREQUENCY: 100 KHZ TYPICAL OVER-CURRENT/SHORT CIRCUIT PROTECTION: 2.0Io CONSTANT CURRENT LIMITING WITH AUTORECOVERY OVER-VOLTAGE PROTECTION: 8.5 VDC MAX WITH ZENER CLAMP OTHER PROTECTION: INPUT FUSING SAFETY APPROVALS : UL 60950 3-TH ED., CUL, CLASS II DIELECTRIC WITHSTAND VOLTAGE: 3000 VAC PRIMARY TO SECONDARY LEAKAGE CURRENT: < 0.25 mA EMI: FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED MTBF: SHALL BE 50,000 HOURS OR GREATER AT 25 C AMBIENT TEMPERATURE. OPERATING TEMPERATURE: 0C TO 40 C DERATE LINEARLY FROM 100% AT 40 C TO 50% AT 70C STORAGE TEMPERATURE: -20 TO 60 C HUMIDITY: 5 TO 95% RELATIVE HUMIDITY WEIGHT: 90 g MAX Foot Note: DASH DESCRIPTION NOTES PART NO REV. Roving Networks will not be liable for the NO. safety and performance of these power supplies if unauthorized access and repair occurs. End user should consult applicable UL, CSA or EN standards for proper installation instructions TOLERANCES: DECIMALS ANGULAR 809 University Ave, Los Gatos, CA 95032 o +/- 1 .xx +/- 0.1 Tel.408-395-6539 Fax 603-843-7550 Limitation of Use: .xxx +/- .005 www.rovingnetworks.com Roving Networks product are not authorized for MILLIMETERS ANGULAR use as mission critical components in life support, o DWG TITLE: N.A. WALL PLUG-IN SWITCHING POWER SUPPLY, DATE: +/- 1 .xx +/- 0.3 INIT.BY: MC hazardous environment, nuclear or 5 WATT, 5.0 V DC 1.0 A .xxx +/- .013 1/18/06 aircraft applications without prior written approval from the CEO of Roving Networks FSCN No.: SIZE REV. DATE: DRAWN: LR MODEL NO: RN-PS-US G, Y A B 1/18/06 Contents of this document are subject to change without prior notice DATE: CAGE CODE: 0GV V90 APRVD:MC PART NO: RN-PS-US-5R-P SHEET 1 OF 3 1/18/06 SCALE: NONEPROPRIETARY INFORMATION: PROPRIETARY OF ROVING NETWORKS ANY REPRODUCTION, DISCLOSURE OR USE OF THIS DRAWING, IN WHOLE OR IN PART, IS HEREBY PROHIBITED EXCEPT AS SPECIFIED IN WRITING BY ROVING NETWORKS 3. ENCLOSURE: UPPER HOUSING: HIGH IMPACT PLASTIC, 94V0 POLYCARBONATE, NON-VENTED, COLOR BLACK LOWER HOUSING: HIGH IMPACT PLASTIC 94V0 POLYCARBONATE, NON- VENTED, COLOR BLACK SIZE: 54.0 x 40.0 x 29.5 + 1 mm WWYY DATE CODE: WW - WEEK YY- YEAR 4. INPUT CONNECTOR: CONFIGURATION: CLASS II MODEL NEMA 1-15P AC POWER RECEPTACLE WITH 2 PRONGS 5. OUTPUT CORD: 2 CONDUCTOR, 20 AWG STRANDED WIRE, FLAT VW-1 RATED UL 2468, COLOR BLACK, LENGTH (L) OF CORD: 1830+ 100/-0 mm. CORD IS MEASURED FROM THE HOUSING TO THE END OF OVERMOLD OF THE CONNECTOR. CABLE IS TO BE MARKED WITH WIRE GAUGE, AND ALL APPLICABLE RATING AND SAFETY APPROVALS. 6. OUTPUT CONNECTOR: STRAIGHT LOCKING FEMALE BARREL 3.5 x 1.3 x 11 mm WITH CENTER POSITIVE: Dia.1.5(+/-0.1) +100 1830 (6FEET) AFTER TINNED -0 LOCKING 8mm +5 100+/-20 80+/-20 38 -0 12015 1.3*3.5*12.1*5.5*11(+/-0.3)1 Negative Positive 809 University Ave, Los Gatos , CA 95032 Tel. 408-395-6539 Fax 603-843-7550 www.rovingnetworks.com DWG TITLE: N.A. WALL PLUG-IN SWITCHING POWER SUPPLY, 5 WATT, 5.0 V DC 1.0 A REV. MODEL NO: RN-PS-US B PART NO: RN-PS-US-5R-P SHEET 2 OF 3