Dimensions: [mm] Recommended Land Pattern: [mm] Electrical Properties:
Properties Test conditions Value Unit Tol.
16,1
Inductance L 100 kHz/ 100 mV @ 18 mA 350 H min.
13,45
Insulation Test Voltage U 1 min 2250 V (DC)
11,43
T
4x O0,89
14 12
Insertion Loss IL 1-100 MHz -1 dB max.
13
11
Return Loss RL 1-30 MHz @ 100 -18 dB min.
9 7 5 3 1 Return Loss RL 30-60 MHz @ 100 -14 dB min.
12 14
11 13
10 8 4 2
Return Loss RL 60-80 MHz @ 100 -12 dB min.
Return Loss RL 80-100 MHz @ 100 -10 dB min.
1 3 5 7 9 2x O3,2
2x O1,7 Crosstalk CT 1-60 MHz -32 dB min.
2 4 8 10
9x O0,89
Crosstalk CT 60-100 MHz -30 dB min.
0,64
16,0 0,25
2,54
Common Mode
CMRR 1-30 MHz -35 dB min.
Rejection Ratio
LEFT LED RIGHT LED 15,75
Green/Yellow Green/Yellow
Scale 1:1
Common Mode
CMRR 30-60 MHz -32 dB min.
Rejection Ratio
unless otherwise defined tolerance: xx 0.05 mm
Common Mode
CMRR 60-100 MHz -30 dB min.
Recommended Panel Cutout: [mm]
Rejection Ratio
Turns Ratio n 1:1 2%
PoE PoE+ (up to 600 mA)
2,03
Data rate 10/100 Base-T
General Information:
Operating Temperature -40 up to +85 C
Storage Conditions (in original
< 40 C ; < 75 % RH
packaging)
Moisture Sensitivity Level (MSL) 1
16,5 0,13
Compliant with IEEE 802.3at
Mating Cycle 750
Scale 1:1
unless otherwise defined tolerance: xx 0.25 mm
Product Marking:
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
Marking 74984104400
METHOD
JefL 001.001 2019-02-20 DIN ISO 2768-1m
Marking - Date Code YYWW
DESCRIPTION
WE-RJ45 LAN Transformer
Wrth Elektronik eiSos GmbH & Co. KG
ORDER CODE
EMC & Inductive Solutions
Through Hole Reflow
Max-Eyth-Str. 1
74638 Waldenburg 74984104400
Germany
BUSINESS UNIT STATUS PAGE
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos Valid 1/5
eiSos@we-online.com
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
21,5 0,25 10,8 0,25
3,3 0,25
2,2 0,25
13,6 0,25
10,7 10,8
8,89
3,05
2,54
14,05 0,13
2,03
4,57Schematic: Recommended Stencil Design: [mm]
1:1
J1
TD+ 1
15,75
J4
PCB thickness Stencil thickness
CD 3
= 1,6 mm 13,45 = 0,15 mm
J5
TD- 2
J2
1:1
RD+ 4 J3
3,8x1,6 (x4)
J7
J8
6,8x2,6 (x2)
RD- 5
J6
7
V1+
V1- 8
V2+ 9 2,2x2,8 (x9)
0,64
V2- 10
2,54
4X22nF/100V
Scale - 1:1
4x75
0,001uF/2kV
Shield
Certification:
Green Green
+ +
RoHS Approval Compliant [ 2011/65/EU&2015/863 ]
14
11 12 13
UL Approval E331896 [ UL-60950 ]
+
+
cULus Approval E331896 [ UL-60950 ]
Yellow Yellow
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
JefL 001.001 2019-02-20 DIN ISO 2768-1m
DESCRIPTION
WE-RJ45 LAN Transformer
Wrth Elektronik eiSos GmbH & Co. KG
ORDER CODE
EMC & Inductive Solutions
Through Hole Reflow
Max-Eyth-Str. 1
74638 Waldenburg 74984104400
Germany
BUSINESS UNIT STATUS PAGE
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos Valid 2/5
eiSos@we-online.com
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
3,05
3,14 2,03
6,14 7,62
13,85