Surface Mount Frequency Mixer SYM-63LH+ Level 10 (LO Power +10 dBm) 1 to 6000 MHz Generic photo used for illustration purposes only Maximum Ratings Features CASE STYLE: TTT166 Operating Temperature -40C to 85C ultra wide bandwidth, 1-6000 MHz +RoHS Compliant IF response to DC Storage Temperature -55C to 100C The +Suffix identifies RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications RF Power 50mW Applications IF Current 40mA Permanent damage may occur if any of these limits are exceeded. test equipment cable TV Reel Size Devices/Reel Pin Connections cellular 7 10, 20, 50, 100, 200 13 500 LO 2 PCS RF 1 satellite distribution ISM/GPS IF 3 WCDMA GROUND 4,5,6 defence communications Electrical Specifications 25C FREQUENCY CONVERSION LOSS* LO-RF ISOLATION LO-IF ISOLATION IP3 (MHz) (dB) (dB) (dB) at center Outline Drawing band Mid-Band (dBm) LO/RF IF m Total L M U L M U Range f -f L U X Max. Max. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Typ. 1-6000 DC-1000 7.5 0.15 9.5 10.8 65 45 35 20 29 20 60 40 25 14 19 12 14 1 dB COMP.: +3 dBm typ. L = low range f to 10 f M = mid range 10 f to f /2 L L L U * Conversion Loss at 30 MHz IF. U = upper range f /2 to f m= mid band 2f to f /2 U U L U PCB Land Pattern is a measure of repeatibility from unit to unit. Typical Performance Data Frequency Conversion Isolation Isolation VSWR VSWR (MHz) Loss L-R L-I RF Port LO Port (dB) (dB) (dB) (:1) (:1) LO LO LO LO LO RF LO +10dBm +10dBm +10dBm +10dBm +10dBm 1.00 31.00 5.83 65.41 60.62 1.68 3.60 10.00 40.00 6.07 63.21 58.28 1.09 3.54 Suggested Layout, 100.00 130.00 6.21 53.47 46.17 1.04 3.45 Tolerance to be within.002 145.00 175.00 6.21 51.34 43.08 1.04 3.46 505.00 535.00 6.28 42.90 33.70 1.37 2.72 inch 1000.00 1030.00 6.65 41.76 34.89 2.07 1.72 Outline Dimensions ( ) mm 1500.00 1530.00 7.31 32.97 23.84 2.07 1.27 A B C D E FG H J 2000.00 2030.00 6.87 30.92 24.37 2.01 1.70 3000.00 3030.00 8.60 26.67 34.89 2.42 2.64 .38 .50 .15 .020 .075 .250 .425 .187 .050 4000.00 4030.00 7.94 28.22 18.49 1.76 2.75 9.65 12.70 3.81 0.51 1.91 6.35 10.80 4.75 1.27 5000.00 5030.00 8.24 36.41 19.92 2.09 2.09 K L M NP Q RS T wt. 5100.00 5130.00 8.18 38.17 20.34 2.05 2.18 .050 .070 .270 .540 .060 .095 .445 .208 .415 grams 5200.00 5230.00 8.20 40.26 20.55 1.86 2.33 1.27 1.78 6.86 13.72 1.52 2.41 11.30 5.28 10.54 0.8 5300.00 5330.00 8.25 42.62 20.82 1.65 2.57 5400.00 5430.00 8.34 43.72 21.01 1.60 2.77 Demo Board MCL P/N: TB-12 5500.00 5530.00 8.43 42.20 21.03 1.76 2.76 Suggested PCB Layout (PL-079) 5600.00 5630.00 8.60 39.70 21.01 2.11 2.84 5700.00 5730.00 8.76 37.69 21.00 2.61 2.88 5800.00 5830.00 8.85 36.36 20.92 2.89 2.84 6000.00 6030.00 9.28 34.92 20.45 2.77 2.19 Electrical Schematic Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions. REV. C C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms) Purchasers of this part are entitled M151107 to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits website at www.minicircuits.com/MCLStore/terms.jsp ED-13824/3 SYM-63LH+ DJ/CP/AM Mini-Circuits 200813 www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales minicircuits.com Page 1 of 2 Available Tape and Reel at no extra cost SYM-63LH+ Performance Charts SYM-63LH+ SYM-63LH+ CONVERSION LOSS L-R ISOLATION at IF Freq of 30 MHz 14.0 100 LO=+7 dBm LO=+10 dBm LO=+13 dBm 90 LO=+7 dBm LO=+10 dBm LO=+13 dBm 80 11.0 70 60 50 40 8.0 30 20 10 5.0 0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000 FREQUENCY (MHz) FREQUENCY (MHz) SYM-63LH+ SYM-63LH+ RF VSWR L-I ISOLATION 5.0 70 LO=+7 dBm LO=+10 dBm LO=+13 dBm 4.5 LO=+7 dBm LO=+10 dBm LO=+13 dBm 60 4.0 50 3.5 40 3.0 30 2.5 20 2.0 10 1.5 0 1.0 0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000 FREQUENCY (MHz) FREQUENCY (MHz) SYM-63LH+ SYM-63LH+ IF VSWR LO VSWR 6.0 2.0 LO=+7 dBm LO=+10 dBm LO=+13 dBm LO=+7 dBm LO=+10 dBm LO=+13 dBm 5.5 1.9 5.0 1.8 4.5 1.7 4.0 1.6 3.5 1.5 3.0 1.4 1.3 2.5 1.2 2.0 1.5 1.1 1.0 1.0 0 200 400 600 800 1000 0 1000 2000 3000 4000 5000 6000 FREQUENCY (MHz) FREQUENCY (MHz) Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms) Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales minicircuits.com Page 2 of 2 VSWR CONVERSION LOSS (dB) ISOLATION (dB) VSWR VSWR ISOLATION (dB)