X-On Electronics has gained recognition as a prominent supplier of 7020-01039-0 Current Transformers across the USA, India, Europe, Australia, and various other global locations. 7020-01039-0 Current Transformers are a product manufactured by Murata. We provide cost-effective solutions for Current Transformers, ensuring timely deliveries around the world.

7020-01039-0 Murata

7020-01039-0 electronic component of Murata
Product Image X-ON
Product Image X-ON
Product Image X-ON

Images are for reference only
See Product Specifications
Part No.7020-01039-0
Manufacturer: Murata
Category: Current Transformers
Description: Current Transformers 150:5A ratio 6VA 5 Amp AC Current
Datasheet: 7020-01039-0 Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0
MOQ : 1
Multiples : 1
1 : USD 49.3175
5 : USD 49.0041
10 : USD 48.8836
25 : USD 48.8836
50 : USD 48.8836
100 : USD 48.8836
N/A

Obsolete
   
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Mounting Style
Inductance
Current Rating
Turns Ratio
Secondary Resistance
Termination Style
Length
Width
Height
Frequency Range
Core Size
Output Current
Packaging
Brand
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Taric
LoadingGif
 
Notes:- Show Stocked Products With Similar Attributes.

We are delighted to provide the 7020-01039-0 from our Current Transformers category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the 7020-01039-0 and other electronic components in the Current Transformers category and beyond.

Image Part-Description
Stock Image 7020-01040-0
Current Transformers 200:5A ratio 8VA 5 Amp AC Current
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 7020-01043-0
Murata Power Solutions Current Transformers 750:5A ratio 10VA 5 Amp AC Current
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 76253/55ENC
Power Transformers 5Vin 5Vout 200mA 6000Vdc 1:1.33 turn
Stock : 382
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Hot Stock Image 76253/35ENC
Power Transformers 3.3Vin 5Vout 100mA 6000Vdc
Stock : 10
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 702W00341
702W00341
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 76250ENC
Power Transformers 1CT:1 turn 6000Vdc Converter Xfmr
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 76600/1C
Pulse Transformers 1:12060uH17.5VusA
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 7020-01041-0
Current Transformers 250:5A ratio 10VA 5 Amp AC Current
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 7020-01044-0
Current Transformers 1000:5A ratio 10VA 5 Amp AC Current
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 7020-01042-0
Current Transformers 600:5A ratio 10VA 5 Amp AC Current
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image T60404-E4658-X043
Current Transformers Current Transformer 6A 1:1500 35Henry
Stock : 862
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SE-CS30-8
Current Transformers 600:1 200M ID XFMR CURRENT
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image C/CT-1216
Board Mount Current Sensors SensCurr Magn 120A with Clamp
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image T60404-E4626-X151
Current Transformers Current Transf 100A 1:2500 2.1H LitzWire
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image T60404-E4626-X501
Current Transformers Current Transf 100A 1:2500 2.1Henry Pins
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EFCT-1FC
Current Transformers CURRENT TRANSFORMER W/ FLUX CONDITIONER
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Hot Stock Image 2277048
Current Transformers PACT MCR-V1-21- 44-250-5A-1
Stock : 10000
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image T60404-E4624-X501
Current Transformers Current Transformer 60A 1:2500 3.0Henry
Stock : 1427
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image T60404-E4627-X001
Current Transformers Current Transformer 200A 1:1000 25Henry
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image T60404-E4624-X002
Current Transformers Current Transformer 60A 1:2500 122Henry
Stock : 423
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.

DMS Accessories www.murata-ps.com 5 Amp AC Current Transformers These commercial grade, UL & CSA recognized, donut style AC current-transformers GENERAL SPECIFICATIONS (ALL MODELS) (CTs) provide an isolated 0-5A output that can be used with Murata Power Solutions ACA5 Insulation Class 600V, 10kV BIL full wave (1) Series of digital ammeters. Installation is straightforward: simply pass the load-carrying Frequency Range 50-400Hz conductor through the 5A CTs primary window, and then route its secondarys leads through the ACA5-ammeters built-in, low-burden, toroid sensor. Supplied Secondary All models feature rugged, fully insulated construction, allowing continuous operation Max. Secondary Lead with primary voltages up to 600Vac, at line frequencies from 50 to 400Hz. Fourteen models Rated Accuracy are available to enable accurate measurements from 50A through 2000A. When combined with Murata Power Solutions ACA5 Series ammeters, secondary lead-extensions may be Burden See Table 1 used for those applications where the CT cannot be installed in the immediate vicinity of UL FIle No. the ammeter. CSA File No. TECHNICAL NOTES Weight IMPORTANT To ensure safe and reliable operation, Current Transformers and asso- (1) Basic Lightning Impulse Insulation Level (BIL): The ciated equipment must be installed and serviced by qualiefi d technical personnel. insulation strength referenced to the crest value of an Never open the CTs secondary connections while the primary is energized. Open impulse voltage-waveform which rises to a crest value in CT secondary wiring can generate potentially lethal voltages when the primary cir- 1.2 microseconds, then drops to the crest value in 50 microseconds. cuit is energized. Contact Murata Power Solutions if you have any doubts regarding the installation or operation of any of our ac-mains measurement instruments and accessories. 1. CT Precautions: In normal operation, a 5A current transformers secondary circuit oper- ates at a relatively low voltage due to its closed-loop, low burden congfi uration (essentially zero Ohms when used with Murata Power Solutions ACA5 series ammeters). However, any CT can generate potentially lethal voltages if its output current is suddenly interrupted. AC POWER SUPPLY For example, loose secondary connections can produce a condition referred to as induc- tive kick. Inductive kick can generate extremely high voltages across the open secondary ACA5-20PC-X-ACX connections. AB TB1 Therefore, all connections made to a CTs secondary leads must only be performed with TO AC LOAD L1 zero current flowing in the primary circuit. Never operate a CT with its secondary circuit open and current flowing in the primary. 5A CURRENT TRANSFORMER 2. CT Connections and Grounding: Some applications require connecting one of the CTs (see technical notes) 5A output terminals to earth/chassis ground. In the USA, consult the latest revision of the National Electrical Code for more information. 0-5A OUTPUT After all mechanical assembly is completed, pass the 5A secondary leads through the ACA5 ammeters built-in toroid, then connect the two leads together as shown in Figure 1. For this connection, and for connections involving lead extensions, pressure-style Figure 1. Typical Connections connectors (commonly called wire nuts) are acceptable as long as they are rated for the currents and voltages involved. 3. Installation: CTs must be installed in a manner that ensures no excessive stresses are applied to the primary conductor that passes through the CT or to the secondary circuit and its associated instruments. Use plastic tie-wraps and/or other suitable non-conductive restraining devices to secure the CT. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MPM DMS-CT.B05 Page 1 of 4DMS Accessories 5 Amp AC Current Transformers TECHNICAL NOTES 4. Reference Documentation: Prior to connecting CTs to any measure- burden column. Accuracy measurements are taken at 100% primary ment device (analog or digital), relay, or other apparatus, be sure to current, using a resistive burden and a nominal line frequency of 60Hz. thoroughly review the applicable devices technical documentation (for 7. Polarity: CTs are marked with H1 (primary) and X1 (secondary) example, Murata Power Solutions ACA5-20PC product data sheet). In polarity indicators. When a CTs only function is to measure amperes, particular, make sure the CTs ratings meet the requirements of your polarity markings can be disregarded. However, correct polarity is application. mandatory in applications in which the phase relationship between 5. Secondary Lead Extensions: When calculating the total burden two currents is involved (watt or watt-hour meters are two examples imposed on a CTs 5A output, Murata Power Solutions ACA5 digital of polarity sensitive applications). Refer to the respective instruments ammeters input impedance is negligible and can be assumed to be documentation for more information. zero Ohms. In many applications, the length of secondary wiring can 8. Thermal Rating Factor: The thermal rating factor denotes the amount be increased up to the value specified in Table 1 without adversely by which the primary current can be increased on a continuous affecting performance. basis over its rated value without exceeding the CTs maximum In order to achieve the specified accuracy, the maximum permissible temperature rise. burden must not exceed the value shown in Table 1. When used with The formula below can be used to calculate thermal rating factors at ACA5 ammeters, the total burden is the sum of the resistance of the temperatures above 30C. CTs 24 leads and any lead-extensions. Make sure all connections 2 (85 - NAT)(RF) are securely tightened and properly strain relieved. If terminal blocks NRF = are used for intermediary connections, refer to the manufacturers NAT torque recommendations. NRF = Rating Factor at New Ambient Temperature Table 1 lists general guidelines for adding lead extensions when RF = 30C Rating Factor using Murata Power Solutions ACA5-Series ammeters as the readout NAT = New Ambient Temperature device. The lengths in Table 1 assume the lead extensions are 16AWG. Stated dimensions are one-way distances between the ACA5 Example: Find the 55C. thermal rating factor of a 2000:5 CT whose and the CT. Make sure all secondary extensions meet or exceed the 30C rating factor is 1.3. specifications of the CTs built-in leads. In order to minimize external 2 (85 - 55)(1.3) noise pick up, lead extensions should be as kept short as possible. = 0.96 NRF = 55 6. Accuracy: The indicated accuracy specifications are valid as long as the total secondary burden does not exceed the value in Table 1s Table 1. Selection Guide Lead Ext. Current Accuracy ( Burden VA Thermal Rating UL File CSA File Weight MPS Part No. Feet Leads Type Ratio 60Hz) (Ohms) Factor ( 30C) Cert Cert (lb) (Meters) 7020-01036-0 50:5 2% 1.5 (0.06) 4 (1.2) 1.3 7020-01037-0 75:5 2% 3.0 (0.12) 10 (3.0) 1.3 7020-01038-0 100:5 1% 3.0 (0.12) 10 (3.0) 1.3 16AWG, 24 E175133 Pending 1.5 UL Style 3173 150:5 1% 6.0 (0.24) 20 (6.1) 1.3 7020-01039-0 7020-01040-0 200:5 1% 8.0 (0.32) 30 (9.1) 1.3 7020-01041-0 250:5 1% 10.0 (0.40) 40 (12.2) 1.3 7020-01123-0 300:5 1% 12.5 (0.50) 50 (15.2) 1.0 7020-01124-0 400:5 1% 12.5 (0.50) 50 (15.2) 1.0 E466945 260320 1.0 500:5 1% 20.0 (0.80) 80 (24.4) 1.0 7020-01125-0 7020-01042-0 600:5 1% 10.0 (0.40) 40 (12.2) 1.0 16AWG, 24 UL Style 1015 7020-01043-0 750:5 1% 10.0 (0.40) 40 (12.2) 1.0 7020-01044-0 1000:5 1% 10.0 (0.40) 40 (12.2) 1.0 E228202 223647 1.5 7020-01045-0 1500:5 1% 12.5 (0.50) 50 (15.2) 1.0 2000:5 1% 15.0 (0.60) 60 (18.3) 1.0 7020-01046-0 See www.murata-ps.com/dpm-availability for model-specific availability. www.murata-ps.com/support MPM DMS-CT.B05 Page 2 of 4

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
MU2
MUP
MUR
MURATA
Murata - TOKO
Murata / IPDiA
Murata Electronics
Murata Electronics N
Murata Electronics North America
MURATA MANUFACTURING
Murata Manufacturing Co.
Murata Power Solutio
Murata Power Solutions
Murata Power Solutions Inc
Murata Power Solutions Inc.
Toko
TOKO AMERICA
Toko America Inc.
TOKO, Inc.
TOKYO PARTS INDUSTRIAL
Tokyo Parts Industrial Group
Best retailer of 0028303 Lapp Kabel in India, USA, Australia image

Aug 1, 2024
The 0028303 Lapp Kabel, from the UNITRONIC® LiYY series, is a high-quality multi-conductor cable featuring three stranded copper conductors with a cross-section of 0.25 mm², enclosed in a grey PVC jacket. Rated for up to 500V, this flexible and durable cable is ideal for industrial automation, cont
254H-03 Headers & Wire Housings by Itek in India, USA image

Nov 19, 2024
The 254H-03 Headers & Wire Housings by Itek are reliable 3-way connectors with a 2.54mm pitch, perfect for creating secure electrical connections in various applications. Manufactured for industries worldwide, including the USA, India, Australia, and Europe, this component ensures efficient power d
89505 002100 Multi-Conductor Cable by Belden image

Nov 5, 2024
Explore the 89505 002100 Multi-Conductor Cable by Belden at Xon Electronics , ideal for high-performance applications requiring EMI protection. This 24AWG 5-pair (5PR) shielded cable is available in a 100-foot spool, with durable construction for reliable signal transmission in industrial, autom
Best Supplier of XT60H-F and XT60H-M Plugs by Amass image

Jul 19, 2024
finding a reliable supplier is crucial for maintaining the quality and performance of your projects. Xon Electronic has established itself as the premier supplier of XT60H-F and XT60H-M plugs , manufactured by Amass. With a presence in the USA, India, Australia, Europe, and other countries, Xon E

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON Electronics
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronics Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing. All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted AS9120 Certified