ICH 360-Watt Series Wide Input Isolated Half Brick DC-DC Input Range (Vdc) Model Number Vout Iout (Vdc) (A) Min Max ICH0130V1xC 9 36 12 30 ICH0415V1xC 9 36 24 15 9 36 28 13 ICH0513V1xC Features 4:1 Input voltage range of 9-36V Single outputs of 12V, 24V or 28V 2250V Isolation voltage (Input-to-Output) Industry Standard half brick package 2.4 x 2.5 x 0.52 (61mm x 64mm x 13.2mm) Efficiency up to 95.6% Excellent thermal performance Over-Current and Short Circuit Protection Over-Temperature protection Monotonic startup into pre-bias loads 200kHz Fixed switching frequency Remote On/Off control (Positive or Negative logic) Good shock and vibration damping Operating Temperature Range -40C to +105C RoHS Compliant Product Overview temperature operation. The 4:1 input voltage 360 Watt single output ICH DC-DC converter provides a precisely regulated dc output. The output The converters high efficiency and high power density are voltage is fully isolated from the input, allowing the output to be accomplished through use of high-efficiency synchronous positive or negative polarity and with various ground rectification technology, advanced electronic circuit, connections. The enclosed half brick package meets the most packaging and thermal design thus resulting in a high rigorous performance standards in an industry standard reliability product. The converter operates at a fixed frequency footprint for mobile (12Vin), process control (24Vin), and of 200kHz and follows conservative component derating Commercial-Off-The-Shelf (28Vin) applications. guidelines. The ICH Series includes an external TRIM adjust and remote Product is designed and manufactured in the USA. ON/OFF control. Threaded through holes are provided to allow easy mounting or the addition of a heat sink for extended Part Number Structure and Ordering Guide Description Part Number Structure Definition and Options Product Family I C IC= Industrial Class Form Factor H H = Half Brick Vout* 0 1 01 = 12Vout, 02 = 5Vout, 03 = 3.3Vout, 04 = 24Vout, 05 = 28Vout Output Current 3 0 Max Iout in Amps Vin Range V 1 V1 = 9 to 36V On/Off Control Logic P N = Negative, P = Positive (Standard) Specific Customer Configuration X X Customer Code, Omit for Standard RoHS Compliant RoHS 6/6 Compliant C *NOTE: Some part number combinations might not be available. Please contact the factory for non-standard or special order products. www.murata-ps.com/support MDC ICH 360W A05 Page 1 of 17 ICH 360-Watt Series Wide Input Isolated Half Brick DC-DC Electrical Specifications All Models Conditions: Ta = 25C, airflow = 300 LFM (1.5m/s), Vin = 24VDC, unless otherwise specified. Specifications subject to change without notice. Parameter Notes Min Typ Max Units Absolute Maximum Ratings Continuous 0 40 V Input Voltage Transient (100ms) 50 V Operating Temperature (See Note 1) Baseplate (100% load) -40 105 C Storage Temperature -55 125 C Isolation Characteristics and Safety Input to Output 2250 V Isolation Voltage Input to Baseplate & Output to Baseplate 1500 V Isolation Capacitance 4500 pF Isolation Resistance 10 20 M Insulation Safety Rating Basic Agency Approvals Designed to meet UL/cUL 60950, IEC/EN 60950-1 Feature Characteristics Fixed Switching Frequency 200 kHz Output Voltage Ripple has twice this frequency Output Voltage Trim Range 10 % Remote Sense Compensation This function is not provided N/A % Output Overvoltage Protection Non-latching 117 124 130 % Overtemperature Shutdown (Baseplate) Non-latching 110 120 C Auto-Restart Period Applies to all protection features 450 500 550 ms Time from UVLO to Turn-On Time from Vin 517 530 ms Vo=90% Vout (NOM) Resistive load Trim from ON to Turn-On time from ON/OFF Control 17 20 ms Vo=90% Vout (NOM) Resistive load Rise Time Vout from 10% to 90% 4 7.5 11 ms ON/OFF Control - Positive Logic ON state Pin open = ON or external voltage applied 2 12 V Control Current Leakage current 0.16 mA OFF state 0 0.8 V Control Current Sinking 0.3 0.36 mA ON/OFF Control - Negative Logic ON state Pin shorted to -INPUT or 0.8 V OFF state Pin open = Off or 2 12 V Thermal Characteristics Thermal resistance Baseplate to Ambient Converter soldered to 3.95 x 2.5 x 0.07 4 layer/ 2oz 5.2 C/W copper FR4 PCB. 1. A thermal management device, such as a heatsink, is required to ensure proper operation of this device. The thermal management medium is required to maintain baseplate < 105C for full rated power. www.murata-ps.com/support MDC ICH 360W A05 Page 2 of 17