MEA1 Series
www.murata-ps.com
1kVDC Isolated 1W Dual Output DC-DC Converters
SELECTION GUIDE
Order Code
MIL. Tel.
V V mA mA % mVp-p % % pF
kHrs
MEA1D0505SC 5 5 100 233 4.8 5.4 12 25 82 85 53 3663 79541
MEA1D0509SC 5 9 56 228 3.7 4.5 8 20 84 86.5 51 3291 80891
FEATURES
MEA1D0512SC 5 12 42 228 4 5 6 20 84 87 45 2860 80521
MEA1D0515SC 5 15 33 225 3.8 4.5 6 20 84 87 46 2374 77687
UL 60950 recognised
MEA1D1205SC 12 5 100 98 3.5 4 9 20 81 85 44 3352 75377
Typical efciency to 89.5%
MEA1D1209SC 12 9 56 95 2.5 3 7 20 83 86.5 61 3083 79125
1kVDC isolation Hi Pot Test MEA1D1212SC 12 12 42 93 2.6 3.5 6 20 85 89 88 2701 78770
MEA1D1215SC 12 15 33 94 2.2 3 5 20 84 88 78 2267 76058
Wide temperature performance at full
MEA1D1505SC 15 5 100 78 3 3.5 8 20 80 84 40 4063 113571
1 Watt load, 40C to 85C
MEA1D1509SC 15 9 56 76 2.1 2.5 7 20 82 87 65 4691 125575
Industry standard pinout
MEA1D1512SC 15 12 42 76 2 2.5 5 20 83 87.5 75 4028 126626
MEA1D1515SC 15 15 33 75 2 2.5 5 20 85 89.5 104 4103 74686
Power sharing on output
MEA1D2405SC 24 5 100 49 2.8 3.5 9 20 81 84.5 47 4581 110817
5V, 12V, 15V, 24V & 48V input
MEA1D2409SC 24 9 56 47 1.8 2.5 7 20 84 87.5 80 3942 102064
MEA1D2412SC 24 12 42 47 1.6 2.5 4 20 84 87 85 3247 97979
5V, 9V, 12V & 15V output
MEA1D2415SC 24 15 33 47 1.5 2.5 3 20 85 88.5 106 3658 108331
No external components required
MEA1D4805SC 48 5 100 26 2.6 4 14 25 77 80 44 4332 121907
MEA1D4809SC 48 9 56 25 1.6 3 8 20 79 82 72 6067 147429
No electrolytic or tantalum capacitors
MEA1D4812SC 48 12 42 25 1.6 3 7 20 78 83 91 3675 139747
Pin compatible with NKA & NMA series
MEA1D4815SC 48 15 33 25 1.3 2.5 6 20 80 83.5 109 3492 73859
MEA1D0505DC 5 5 100 232 5 6.2 12 25 82 85 52 2978 88417
MEA1D0509DC 5 9 56 227 3.9 5 9 20 84 86.7 49 4087 130861
PRODUCT OVERVIEW
MEA1D0512DC 5 12 42 226 4.2 5.3 7 20 84 87 47 3394 121694
The MEA series is the new high performance
MEA1D0515DC 5 15 33 224 4.1 5.3 6 20 84 87.5 46 2641 105112
version of our 1W NMA series. The MEA series
MEA1D1205DC 12 5 100 97 3.6 4.5 9 20 81 84.5 43 3465 112889
is more efcient and offers improved regulation
MEA1D1209DC 12 9 56 95 2.6 3.5 7 20 83 86.5 64 3623 69665
performance 5% for applications where a wide
MEA1D1212DC 12 12 42 93 2.7 3.5 6 20 85 89 89 3267 69830
output voltage variation cannot be tolerated. They
MEA1D1215DC 12 15 33 94 2.3 3 6 20 84 88 76 2339 95016
are ideally suited for providing dual rail supplies
MEA1D1505DC 15 5 100 78 3.1 4 9 20 80 84 42 2929 59216
with the added benet of galvanic isolation to
MEA1D1509DC 15 9 56 76 2.2 3 6 20 82 87 50 2551 96783
reduce switching noise. All of the rated power
MEA1D1512DC 15 12 42 76 2 2.7 6 20 83 87.5 77 2665 102007
may be drawn from a single output providing the
MEA1D1515DC 15 15 33 75 2 2.7 6 20 85 89.5 106 2192 87932
total load does not exceed 1 Watt.
MEA1D2405DC 24 5 100 49 2.8 4 10 20 81 84.5 47 3427 95206
MEA1D2409DC 24 9 56 48 2 3.8 8 20 84 87 77 3686 110546
MEA1D2412DC 24 12 42 47 1.6 2.5 6 20 84 87 83 2855 62894
MEA1D2415DC 24 15 33 47 1.5 2.3 6 20 85 88 100 2435 90783
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load.
For full details go to
All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied.
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_MEA1.C10 Page 1 of 9
Nominal Input
Voltage
Output
Voltage
Output Current
Input Current at
Rated Load
Load Regulation
(Typ)
Load Regulation
(Max)
Ripple & Noise
1
(Typ)
Ripple & Noise
1
(Max)
Efciency (Min.)
Efciency (Typ.)
Isolation
Capacitance
2
MTTFMEA1 Series
1kVDC Isolated 1W Dual Output DC-DC Converters
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Continuous operation, 5V input types 4.5 5 5.5
Continuous operation, 12V input types 10.8 12 13.2
Voltage range Continuous operation, 15V input types 13.5 15 16.5 V
Continuous operation, 24V input types 21.6 24 26.4
Continuous operation, 48V input types 43.2 48 52.8
5V input types 4 12
12V input types 4 12
Reected ripple current 15V input types 3 10 mA p-p
24V input types 3 10
48V input types 22 35
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power TA=-40C to 85C 1W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High VIN to low VIN 1.05 1.1 %/%
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Flash tested for 1 second 1000 VDC
Resistance Viso= 1000VDC 10 G
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
MEA1D05xxxC, MEA1D1212xC, MEA1D1515xC 65
MEA1D1205xC, MEA1D1209xC, MEA1D1215xC, MEA1D1505xC,
Switching frequency 85 kHz
MEA1D1509xC, MEA1D1512xC, MEA1D24xxxC
MEA1D48xxxC 60
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specication All output types -40 85
Storage -50 125 C
Case Temperature above ambient 20
Cooling Free air convection
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1mm from case for 10 seconds 260C
Input voltage VIN, 5Vin types 7V
Input voltage VIN, 12Vin types 15V
Input voltage VIN, 15Vin types 18V
Input voltage VIN, 24Vin types 28V
Input voltage VIN, 48Vin types 54V
www.murata-ps.com/support