MGJ6 Half Bridge Series www.murata-ps.com 5.7kVDC Isolated 6W Dual Output Gate Drive SM DC-DC Converters SELECTION GUIDE Output 1 VH Output 2 VL 1 Order Code Input Voltage Range FEATURES VmA W VmA W V No opto feedback MGJ6D05H24MC 4.5 - 9 24 125 3 24 125 3 Patent protected MGJ6D12H24MC 9 - 18 24 125 3 24 125 3 MGJ6D24H24MC 18 - 36 24 125 3 24 125 3 Two isolated output voltages for IGBT/SiC & Mosfet gate drives in half bridge SELECTION GUIDE (Continued) conguration Output 1 VH Output 2 VL Reinforced insulation to UL60950 with 8mm creepage & clearance recognised ANSI/AAMI ES60601-1, 2 MOPP recognised 1 Order Code Characterised CMTI >100kV/S Input Characterised partial discharge performance Voltage Range 5.7kVDC isolation test voltage Hi Pot Test % mVp-p % mVp-p V Ultra low isolation capacitance typically MGJ6D05H24MC 4.5 - 9 2 3 100 150 2 3 100 150 15pF MGJ6D12H24MC 9 - 18 2 3 100 150 2 3 100 150 Continuous barrier withstand voltage 3kVDC MGJ6D24H24MC 18 - 36 2 3 100 150 2 3 100 150 5V, 12V & 24V input voltages 105C operating temperature SELECTION GUIDE (Continued) 3 MTTF PRODUCT OVERVIEW Offering two congurable isolated output voltages 1 Order Code of 24V, the MGJ6-HB series of DC-DC converters is ideal for simultaneously powering high side and low side gate drive circuits for IGBTs, Silicon and V mA % kHrs Silicon Carbide Mosfets in half bridge circuits. The MGJ6D05H24MC 5 1500 76 79.5 715 2377 MGJ6-HB series is characterised for high isolation and dv/dt requirements commonly seen in bridge MGJ6D12H24MC 12 600 81 84 716 1756 circuits used in motor drives and inverters. MGJ6D24H24MC 24 300 82 85 712 1768 1. Components are supplied in tape and reel packaging, please refer to tape and reel specication section. Orderable part numbers are MGJ6DXXH24MC-R7 ( 23 pieces per reel), or MGJ6DXXH24MC-R13 ( 92 pieces per reel). 2. See ripple & noise test method. 3. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25C with nominal input voltage at full load. 4. Between 50% and 100% rated output current. For full details go to All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. www.murata-ps.com/rohs www.murata-ps.com/support KDC MGJ6C-HB.C02 Page 1 of 15 Nominal Input Voltage 4 Load Regulation (Typ) Input Current Rated Output Voltage at Rated Load 4 Load Regulation (Max) Rated Output Current Efciency 2 Ripple & Noise (Typ) (Min) Output Power 2 Ripple & Noise (Max) Efciency (Typ) Load Regulation (Typ) Rated Output Voltage Load Regulation (Max) MIL 217 Rated Output Current 2 Ripple & Noise (Typ) Telecordia 2 Output Power Ripple & Noise (Max)MGJ6 Half Bridge Series 5.7kVDC Isolated 6W Dual Output Gate Drive SM DC-DC Converters INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 5V input types 4.5 5 9 Voltage range 12V input types 9 12 18 V 24V input types 18 24 36 Turn on threshold MGJ6D05 3.8 Turn off threshold MGJ6D05 3.2 Turn on threshold MGJ6D12 8.1 Under voltage lock out V Turn off threshold MGJ6D12 7.5 Turn on threshold MGJ6D24 16.7 Turn off threshold MGJ6D24 16.3 5V input types 30 mA Input ripple current 12V input types 40 p-p 24V input types 25 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Minimum load Below 10% load, output may rise to 30V maximum voltage 10 % Voltage set point accuracy All output types +3 /-2 % Total regulation 10 % Line regulation Low line to high line 0.5 1 % GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Power Consumption Disable pin pulled low 45 mW Switching frequency 100 kHz ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Flash tested for 1 second (input to output) 4000 VAC Flash tested for 1 second (output to output) 2500 Isolation test voltage Qualication tested for 1 minute (input to output) 5700 VDC Qualication tested for 1 minute (output to output) 3000 Resistance Viso = 1kVDC 100 G Continuous barrier withstand voltage Non-safety barrier application 3000 VDC UL60950-1 Reinforced 250 Safety standard Vrms ANSI/AAMI ES60601-1 2 MOPP 250 Input to output 8 Creepage & clearance mm Output to output 8 Primary to Output 1 VH 15 Isolation capacitance pF Primary to Output 2 VL 15 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation See derating graphs -40 105 Storage -55 125 C 5V input types 30 Product temperature rise above ambient 100% Load, Nom VIN, Still Air All other input types 20 ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Input voltage, MGJ6 5V input types 12V Input voltage, MGJ6 12V input types 20V Input voltage, MGJ6 24V input types 40V www.murata-ps.com/support KDC MGJ6C-HB.C02 Page 2 of 15