MHM314 series / Ionizer module / Key Features // Ideal for air cleaning, static elimination and skin moisture keeping applications 8Mpcs/cc typ. Negative ions amount : 8Mpcs/cc typ. 0.15mg/h Ozone amount : 0.15mg/h or less Design that separates the high voltage power supply from the ion generator DC12V Compatible with DC12V input -1050: -1070 Wide operating ambient temperature-1050Ion generator part : -1070 Adoption of original ion generating device(Retain related patents) RoHS RoHS Compliant 1. / ORDERING GUIDE HV X(mm) GND Y(mm) (g) (pcs) Model Number Length of HV wire X Length of GND wire Y Weight Quantity per box MHM314-01 29010 29510 26 200 MHM314-02A 19510 20010 25 200 2.(1) / INPUT CHARACTERISTIC Parameter Condition Min. Typ. Max. Units Vin(2) Input Voltage Operating Range DC 10.8 12 13.2 V Vin DC12V - 75 200 mA Input Current DC12V - 0.9 2.4 W Input Power (1) 1535 3080% 252 5010% 8 () Unless otherwise specified, tests and measurements will be made under the standard conditions ( Temperature : 1535,Relative humidity : 3080% ). If there may be any doubt on results, tests and measurements will be made under the following conditions, temperature : 252,Relative humidity : 5010%. If the test will be made under the special conditions, the measurement will be made leaving under the standard conditions for 8 hours or more. (2) On-Off 100 Input switching time should be less than 1milion times. MHM314 series / Ionizer module 3.3 / OUTPUT CHARACTERISTIC Parameter Condition Min. Typ. Max. Units (4) DC12V(Input Voltage) 1,800,000 8,000,000 - pcs/cc Initial value of Ion amount (4) DC12V(Input Voltage) -1,500 - -150 nA Initial value of Ion current (5) DC12V(Input Voltage) 0.0 - 0.5 ppm Initial value of Ozone density (5) DC12V(Input Voltage) 0.0 - 0.15 mg/h Initial value of Ozone amount (3) 1535 3080% 252 5010% 8 () Unless otherwise specified, tests and measurements will be made under the standard conditions (Temperature : 1535,Relative humidity : 3080%). If there may be any doubt on results, tests and measurements will be made under the following conditions, temperature : 252,Relative humidity : 5010%. If the test will be made under the special conditions, the measurement will be made leaving under the standard conditions for 8 hours or more. (4) ( ) NKMH-103 / Place the ionizer module as shown below for ion measurement. Ion amount will be measured by the instrument (Ion counter or DC current meter with copper plate) located away from the ionizer module. Ion counter : NKMH-103, Hokuto Electronics 50mm 200mm Copper Plate Ionizer Ionizer Ion 100x100mm Module Module Counter Input Input voltage voltage A 1-b 1-a Fig.1-b Ion measurement Fig.1-a Ion measurement(Ion counter) (DC current meter with copper plate)