MTU1 Series
www.murata-ps.com
Isolated 1W Single & Dual Output SM DC-DC Converters
SELECTION GUIDE
1
Order Code
VV mA % mVp-p mA % % pF kHrs
MTU1S0305MC 3.3 5 200 8.9 11.0 26 60 367 79 81 14 7660
MTU1S0505MC 5 5 200 7.3 9 35 60 241 80 83 19 5664
MTU1S0509MC 5 9 111 6.1 7.5 15 25 233 83 86 20 5488
FEATURES
MTU1S0512MC 5 12 83 5.6 7.5 15 25 230 84 87 21 5186
Patent Protected
MTU1S0515MC 5 15 67 5.3 6.5 15 25 230 84 87 22 4773
MTU1S1205MC 12 5 200 5.6 8 20 40 99 80 84 22 5641
UL60950 recognised
MTU1S1209MC 12 9 111 3.9 6 15 25 96 82 87 31 5467
2
Footprint over pins 0.69cm MTU1S1212MC 12 12 83 3.5 6 10 25 95 83 88 40 5165
MTU1S1215MC 12 15 67 3.2 5 10 25 95 84 88 35 4753
Single & dual isolated output
MTU1D0305MC 3.3 5 100 8.0 9.5 18 35 356 80 83 17 5292
1kVDC Isolation Hi Pot Test MTU1D0505MC 5 5 100 6.6 8 14 30 235 81 84 18 5053
MTU1D0509MC 5 9 56 5.6 6.5 7 20 229 83 86 21 5078
Efciency up to 88% (Typ.)
MTU1D0512MC 5 12 42 5.0 6 8 20 228 83 87 19 5545
MSL Level 1 MTU1D0515MC 5 15 33 5.1 6.5 8 20 224 84 88 22 5293
MTU1D1205MC 12 5 100 4.3 5 14 30 98 80 85 18 4335
3
Power density 1.71W/cm
MTU1D1209MC 12 9 56 3.1 4 7 20 95 82 87 27 4601
MTU1D1212MC 12 12 42 3.0 4 8 20 94 84 88 35 4834
Wide temperature performance at full
MTU1D1215MC 12 15 33 2.6 3.5 8 20 94 84 88 35 4782
1 Watt load, 40C to 85C
UL 94V-0 Package material
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
3.3V, 5V & 12V Input
Continuous operation, 3.3V input types 2.97 3.3 3.63
5V, 9V, 12V & 15V single & dual outputs
Voltage range Continuous operation, 5V input types 4.5 5.0 5.5 V
Continuous operation, 12V input types 10.8 12.0 13.2
Toroidal magnetics
3.3V input types 10
Custom solutions available
Single output types 5V input types 6
Reected ripple current mA p-p
12V input types 5
Multi-layer ceramic capacitors
Dual output types All variants 5
PRODUCT OVERVIEW
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
The MTU1 series is a new range of miniature
Isolation voltage Flash tested for 1 second 1000 VDC
surface mount, high performance 1W DC-DC
Resistance Viso= 1000VDC 10 G
converters. With a footprint reduction of over 50%
from the previous generation of 1W SMD DC-DC,
GENERAL CHARACTERISTICS
the MTU1 series offers 1W of available output
Parameter Conditions Min. Typ. Max. Units
power over the full industrial temperature range of
MTU1D0305MC 70
-40C to 85C. The MTU1 series is more efcient
3.3V & 5V input, all output types
and offers improved regulation performance for
82
(except MTU1D0305MC)
Switching frequency kHz
applications where a wide output voltage variation
12V input, single output types 90
can not be tolerated.
12V intput, dual output types 100
The devices are suitable for all applications where
high volume production is envisaged.
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated power TA=-40C to 85C 1.0 W
Voltage set point accuracy
See tolerance envelope
Line regulation High VIN to low VIN 1.0 1.1 %/%
1. If components are required in tape and reel format sufx order code with -R, e.g. MTU10505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
For full details go to
3. See ripple & noise characterisation method.
www.murata-ps.com/rohs
All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied.
www.murata-ps.com/support
KDC_MTU.C03 Page 1 of 9
Nominal Input
Voltage
Output
Voltage
Output Current
Load Regulation
(Typ.)
Load Regulation
(Max)
Ripple & Noise
3
(Typ.)
Ripple & Noise
3
(Max.)
Input Current at
Full Load
Efciency (Min.)
Efciency (Typ.)
Isolation
Capacitance
2
MTTFMTU1 Series
Isolated 1W Single & Dual Output SM DC-DC Converters
ABSOLUTE MAXIMUM RATINGS
Input voltage VIN, MTU1S03 types 5.5V
Input voltage VIN, MTU1S05 types 7V
Input voltage VIN, MTU1S12 types 15V
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specication All output types -40 85
Storage -55 125
MTU1xxx05MC 15 C
1
Case temperature rise above ambient MTU1xxx09MC 14
MTU1xxx12MC & MTU1xxx15MC 11
Cooling Free air convection
1. Measured after 1 hour continuous operation at nominal VIN full load at the center of each PCB.
www.murata-ps.com/support