NDY Series www.murata-ps.com Isolated 3W Wide Input DC-DC Converters SELECTION GUIDE Output current 3 MTTF Min. Order code Full load 1 Load V (Nom.) V mA mA mA % pF kHrs NDY0505C 5 5 100-150 400-600 615 66 40 1939 NDY0509C 5 9 55-83 222-333 563 72 52 1926 NDY0512C 5 12 42-62 166-250 548 71 43 1907 FEATURES NDY0515C 5 15 33-50 133-200 533 73 44 1924 UL 60950 recognised NDY1205C 12 5 150 600 362 71 36 1928 NDY1209C 12 9 83 333 320 78 52 1916 Industry standard footprint NDY1212C 12 12 62 250 316 78 44 1897 Efciency to 82% NDY1215C 12 15 50 200 308 79 47 1914 NDY2405C 24 5 150 600 174 70 36 1673 1kVDC Isolation Hi Pot Test NDY2409C 24 9 83 333 156 78 52 1663 2:1 wide input range NDY2412C 24 12 62 250 154 80 44 1644 Single isolated output NDY2415C 24 15 50 200 150 82 54 1657 NDY4805C 48 5 150 600 87 73 35 1668 Short circuit protection Low prole 24 pin case NDY2403C 24 3.3 227 909 178 70 30 1671 Operating temperature range -40C to 85C Recommended 5V, 12V, 24V & 48V input Alternative NDY4803C 48 3.3 227 909 87 71 30 1676 NCS3S4803SC 3.3V, 5V, 9V, 12V & 15V output NDY4809C 48 9 83 333 78 80 52 1663 Contact Murata Internal SMD construction NDY4812C 48 12 62 250 77 81 44 1648 NCS3S4812SC NDY4815C 48 15 50 200 76 81 53 1661 NCS3S4815SC Fully encapsulated INPUT CHARACTERISTICS DESCRIPTION Parameter Conditions Min. Typ. Max. Units The NDY series is a range of low prole DC-DC All NDY05XX 4.5 5 9 converters offering a single regulated output over a All NDY12XX 9 12 18 2:1 input voltage range. All parts deliver 3W output Voltage range VDC All NDY24XX 18 24 36 power up to 85C without heatsinking, except the All NDY48XX 36 48 72 4.5V to 9V input voltage range which should be NDY2403 180 360 derated to 2W at the lower input voltage. A yback NDY4803 140 290 oscillator design with isolated feedback is used to All NDY05XX 400 500 give regulation over the full operating range of 25% 2 mA p-p Reected ripple current All NDY12XX 150 170 to 100% of full load. It is strongly recommended All other NDY24XX 290 360 that external capacitors be used on input and All other NDY48XX 100 127 output to guarantee performance over full load and input voltage range. 1. Refer to power derating graph. 2. Measured at full load with external input/output capacitors, refer to lter circuit 1. 3. Calculated using MIL-HDBK-217F with nominal input voltage at full load (ground benign) at 25C. For full details go to www.murata-ps.com/rohs All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. www.murata-ps.com/support KDC NDY.I01 Page 1 of 5 Input voltage Rated output voltage Input current full load 2 Efciency (Min.) Isolation capacitanceNDY Series Isolated 3W Wide Input DC-DC Converters ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Lead temperature 1.5mm from case for 10 seconds 300C Minimum load 25% of rated load Input voltage 05 types 10V Input voltage 12 types 20V Input voltage 24 types 40V Input voltage 48 types 80V Internal dissipation 1.7W OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage set point accuracy With external input/output capacitors 1 5 % Low line to high line, 3.3V output with external input/output capacitors 0.05 0.25 % Line regulation Low line to high line, all other outputs with external input/output capacitors 0.05 0.5 % 25% load to 100% load, 3.3V output with external input/output capacitors 0.6 1.0 % Load regulation 25% load to 100% load, all other outputs with external input/output capacitors 0.2 0.5 % BW = 20Hz to 300kHz, 3.3V output with external input/output capacitors 80 120 1 Ripple mV rms BW = 20Hz to 300kHz, all other outputs with external input/output capacitors 5 10 BW = DC to 100MHz, 3.3V output with external input/output capacitors 180 1 Noise mV p-p BW = DC to 20MHz, all other outputs with external input/output capacitors 50 100 GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 100% load VIN nominal 3.3V output 160 220 25% load VIN nominal 3.3V output 290 560 Switching frequency kHz 100% load VIN nominal, all other outputs 80 220 25% load VIN nominal, all other outputs 290 560 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation Ambient temperature -40 85 C Storage -50 130 Cooling Free air convection ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 1000 VDC Resistance Viso=500VDC 1 G 1. For lower ripple refer to circuit for reduced ripple. www.murata-ps.com/support KDC NDY.I01 Page 2 of 5