RoHS Compliance This component is compliant with RoHS directive. This component was always RoHS compliant from the first date of manufacture. PX1002 Designed for TDMA IS-54 Receiver IF Applications Low Insertion Loss Excellent Selectivity 86.85 MHz Hermetic 13.3 X 6.5 mm Surface-mount Case Unbalanced Input and Output SAW Filter Absolute Maximum Ratings Rating Value Units Maximum Incident Power in Passband +10 dBm Maximum DC Voltage Between any 2 terminals 30 VDC Storage Temperature Range -40 to +85 C Suitable for Lead-free Soldering - Maximum Soldering Profile 260 C for 30 s SM13365-12 Electrical Characteristics Characteristic Sym Notes Min Typ Max Units f 86.850 Nominal Center Frequency MHz C 1 Passband Insertion Loss at fc IL 3 4.0 dB BW 3 dB Passband 12 25 kHz 3 dB Amplitude Ripple over fc 15 kHz 1.0 P-P 1, 2 s Group Delay Variation over fc 10 kHz GDV 6.0 P-P Third-Order Intermod. for -20 dBm tones at fc 60 & 120 kHz -95 dBm Rejection fc 60 kHz 11 16 fc -880 kHz to fc -940 kHz 1, 2, 3 65 dB Ultimate 65 T Operating Temperature Range 1 -20 +70 C A Impedance Matching to 50 unbalanced External L-C Case Style SM13365-12 13.3 X 6.5 mm Nominal Footprint Lid Symbolization (YY=year, WW=week) See note 4 RFM PX1002 YYWW Standard 7 Reel Quantity 500 units Standard 13 Reel Quantity 1000 units Electrical Connections Connection Terminals Port 1Hot 2 Port 1 Gnd Return 3 Port 2 Hot 8 Port 2 Gnd Return 9 Case Ground All Others Caution: Electrostatic Sensitive Device. Observe precautions for handling. NOTES: 1. Unless noted otherwise, all specifications apply over the operating temperatureEN or indicatesengineering prototypes range with filter soldered to the specified demonstration board with impedance 5. The design, manufacturing process, and specifications of this filter are subject matching to 50 and measured with 50 network to change. analyzer. 6. Either Port 1 or Port 2 may be used for either input or output in the design. 2. Unless noted otherwise, all frequency specifications are referenced to the However, impedances and impedance matching may vary between Port 1 and nominal center frequency, fc. Port 2, so that the filter must always be installed in one direction per the circuit 3. Rejection is measured as attenuation below the minimum IL point in the design. passband. Rejection in final user application is dependent on PCB layout and 7. US and international patents may apply. external impedance matching design. See Application Note No. 42 for details. 8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered trademarks 4.LRI or after the part number indicateslow rate initial productio and of Murata Manufacturing Co., Ltd. Copyright Murata Manufacturing Co., Ltd. All rights reserved. 2006 PX1002 (R) 7/1/19 Page 1 of 5 www.murata.comCopyright Murata Manufacturing Co., Ltd. All rights reserved. 2006 PX1002 (R) 7/1/19 Page 2 of 5 www.murata.com