SF2133E Low Loss SAW Filter Surface Mount 3.0 x 3.0 mm Package Complies with Directive 2002/95/EC (RoHS) Pb 1747.5 MHz Absolute Maximum Ratings SAW Filter Rating Value Units Input Power Level 5 dBm DC Voltage on any Non-ground Terminal 3 V Operating Temperature Range -40 to +90 C Storage Temperature Range in Tape and Reel -40 to +90 C Maximum Soldering Profile, 5 cycles/10 seconds maximum 265 C SM3030-6 Electrical Characteristics Max Max Characteristic Sym Notes Min Typ Units -20 to +70 C -40 to +90C Center Frequency f 1747.5 MHz C Insertion Loss, 1710 to 1785 MHz IL 2.6 4.0 4.1 dB dB Amplitude Ripple, 1710 to 1785 MHz 1.6 2.5 3.0 P-P Attenuation Referenced to 0 dB: 10 to 1670 MHz 15 23 1670 to 1690 MHz 6 24 dB 1805 to 1880 MHz 6 24 1880 to 4500 MHz 15 25 4500 to 5000 MHz 10 14 Input/Output VSWR, 1710 to 1785 MHz 1.8:1 2.5:1 2.5:1 Source Impedance Z 50 S Load Impedance Z 50 L Case Style SM3030-6 3.0 x 3.0 mm Nominal Footprint Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator 679, YWWS Standard Reel Quantity Reel Size 7 Inch 500 Pieces/Reel Reel Size 13 Inch 3000 Pieces/Reel Electrical Connections Connection Terminals Input 2 Output 5 Case Ground All others CAUTION: Electrostatic Sensitive Device. Observe precautions for handling. NOTES: 1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance matching to 50 and measured with 50 network analyzer. 2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc. 3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external impedance matching design. See Application Note No. 42 for details. 4.LRI or after the part number indicateslow rate initial productio andEN or indicatesengineering prototypes 5. The design, manufacturing process, and specifications of this filter are subject to change. 6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port 2, so that the filter must always be installed in one direction per the circuit design. 7. US and international patents may apply. 8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered trademarks of Murata Manufacturing Co., Ltd. Copyright Murata Manfacturing Co., Ltd. All rights reserved. October 2016 SF2133E (R) 10/18/16 Page 1 of 5 www.murata.comCopyright Murata Manfacturing Co., Ltd. All rights reserved. October 2016 SF2133E (R) 10/18/16 Page 2 of 5 www.murata.com