5 1 3 1 3 6 2 4 2 4 7 SAFETY CONSIDERATIONS PANEL CUTOUT WIRING RANGE SELECTION This device is marked with the international Caution, risk of danger symbol. It is AC POWER WIRING 2.677 +0.028/-.000 important to read this manual before installing or commissioning this device as it Connect the ac main power connections as shown below. contains important information relating to Safety and EMC (Electromagnetic 68.00 +0.70/-0.00 Compatibility). EARTH NEUTRAL Unpacking & Inspection Unpack the instrument and inspect for obvious shipping damage. Do not attempt LINE to operate the unit if damage is found. GREEN WIRE R 0.06 1.5 0.874 +.012/-.000 N This instrument is a DIN rail mount device. Installation of this instrument should L be done by Qualified personnel. In order to ensure safe operation, the following P1 22.20 +0.30/-0.00 4 PLCS 5 instructions should be followed. FUSE 6 ORANGE SWITCH 7 CONNECTOR This instrument has no power-on switch. An external switch or circuit-breaker shall be Check for proper Earth grounding in the Screws included in the building installation as a disconnecting device. It shall be marked to indicate power distribution system (single phase). underneath this function, and it shall be in close proximity to the equipment within easy reach of the PANEL THICKNESS operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth CAUTION: Do not connect ac power to your meter until you wire), and it shall meet the relevant requirements of IEC 9471 and IEC 947-3 (International 0.25 6.4 MAX have completed all input and output connections. Failure to Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord. 0.03 0.8 MIN do so may result in injury This device must only be installed CURRENT / VOLTAGE INPUT 205-P & -E S3 Furthermore, to provide protection against excessive energy being drawn from the mains electrically by specially trained electrician with supply in case of a fault in the equipment, an overcurrent protection device shall be installed. 4-20 mA D, E corresponding qualifications. The main power input to the The Protective Conductor must be connected for safety reasons. Check DIMENSIONS 0-0.2 V dc E unit as well as the AC input signal to be measured must that the power cable has the proper Earth wire, and it is properly connected. It is agree with the wiring instruction. not safe to operate this unit without the Protective Conductor Terminal 1-5 V dc A connected. 0.945 24.00 2.835 0-10 V dc B 72.00 Do not exceed voltage rating on the label located on the top of the instrument The meter is factory set to the power specified by the customer at the 0-100 V dc C housing. 0.197 time of ordering. The voltage is printed on the label under Input Always disconnect power before changing signal and power connections. 5.00 VOLTAGE INPUT RANGE 205-A S3 power. Do not use this instrument on a work bench without its case for safety reasons. Do not operate this instrument in flammable or explosive atmospheres. 199.9 mV dc - Do not expose this instrument to rain or moisture. 1.999 V dc A Unit mounting should allow for adequate ventilation to ensure instrument does To connect power to the unit, attach wires, as shown from the ~AC not exceed operating temperature rating. power cord to the orange 3-pin female connector that is supplied with 19.99 V dc B Use electrical wires with adequate size to handle mechanical strain and power 4.134 the meter. Plug the female connector into the orange P1 (male) requirements. Install without exposing bare wire outside the connector to 100.0 V dc C 105.00 minimize electrical shock hazards. connector at the rear of the meter. EXCITATION VOLTAGE 205-E ONLY S2 S4 EMC Considerations 4.60 10 V, (standard internal reference) B, D A Whenever EMC is an issue, always use shielded cables. DC POWER WIRING 116.8 Never run signal and power wires in the same conduit. 24 V, (standard internal reference) B, D - The meter can be No Connection N/C Use signal wire connections with twisted-pair cables. External 10 V, (reference based on excitation voltage) A, C A Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems configured at the + DC Power persist. factory to operate on DC DC Supply Voltage operation was configured per customer order. 115 and non-isolated power. The 230 Vac operation use the same transformer and may be reversed 2.661 0.858 21.80 DC voltage option is INSTALLATION 67.60 with simple wiring installation. specified at the time of P1 SIDE VIEW TOP VIEW ordering. An AC powered meter ORANGE 1. Unpack and verify that all equipment has been received. If there CONNECTOR CAUTION: Disconnect power before attempting to convert or cannot be converted to a DC are any questions about the shipment, contact the service All dimensions are in inches millimeters . remove the unit. powered meter or vice versa. Screws department nearest you. underneath 2. Cut or punch a hole in the panel where you want the meter to go. You must remove the printed circuit board from the case in order to To connect power to the unit, attach wires, as shown, to the orange 3- 3. Remove the lens by inserting a paper clip or small flat screwdriver change from 115 Vac to 230 Vac (and vice versa). These changes REMOVING BOARD FROM CASE pin female connector that is supplied with the meter. Plug the female into the rounded corner of the lens and lift out. must be performed by a qualified technician in order to avoid damage PULL TAB HERE connector into the orange P1 (male) connector at the rear of the 4. Remove the two mounting screws from both sides of display. Pry PUSH BOARD ASS Y FROM HERE PC BOARD meter. both sides of the mounting clamp out and down to remove it from TRANSFORMER AC VOLTAGE INSTALL REMOVE the case. SIGNAL INPUT WIRING 205-E 48131 115 Vac W1, W3 W2 5. Insert the meter into the panel cutout and reinstall the mounting Current 48131 230 Vac W2 W1, W3 12 34 56 7 clamp from the rear. Transmitter + 6. Reinstall the mounting screws to secure the meter into the panel. + EXC CALIBRATION / 205-P & 205-E Do not overtighten the screws. P1 Sig Hi 7. Pop the lens back in, making sure the dull side of the lens faces 1. Apply the minimum current or voltage to the signal input. Sig Lo towards you. Adjust the zero pot for the minimum display reading 1 count. PANEL CUTOUT 2. Apply the maximum current or voltage to the signal input. P1 Adjust the span pot for the maximum display reading 1 count. EXC REAR OF CASE 3. Repeat steps 1 and 2 until 1 count desired reading. Reinstall the CASE lens. Screws underneath ELECTRICAL CONNECTIONS CALIBRATION / 205-A SIGNAL INPUT WIRING 205-P & 205-A 1. Apply a voltage equivalent to 95% of the range selected to the POWER AND SIGNAL INPUT signal input. ~~ AC POWER = DC POWER Hold 2. Adjust the span pot for a reading of 1900 1 count. Switch P1 205-E 205-P & 205-A 205-P & 205-A Digital Return 3. Reinstall the lens. 1 SIG HI (+S) SIG HI (+S) SIG HI (+S) Decimal + Point S1 2 SIG LO (-S) SIG LO (-S) SIG LO (-S) Current ZERO SPAN DC Current 3 + Exc Hold Hold 1.999 A OR + ~ 4 - Exc Digital Return Digital Return Voltage Z S 19.99 B DC Voltage P1 A MOUNTING CLAMP 5 AC Earth GND () AC Earth GND ( ) -DC (-) 199.9 C B S1 C 6 AC Neutral (N) AC Neutral (N) + DC (+) 1999 Store jumper S1 MOUNTING SCREW (2) Screws above A LENS 7 AC Line (L) AC Line (L) No Connection (N/C) underneathAVAILABLE MODELS SPECIFICATIONS SPECIFICATIONS (continued) DESCRIPTION PART Field selectable/scalable for 4-20 mA, 0-199.9 mV dc, 205-P 1-5 V dc, 0-10 V dc, 0-100 V dc input ANALOG INPUT / 205-E & 205-P REQUIRED EXTERNAL FUSE PROTECTION 205-P with sensor excitation output 205-E Field selectable for ranges 1999.9 mV, 1.999 V, 205-A Range 4-20 mA 0-0.2 V 1-5 V 0-10 V 0-100 V 24Vac 160mA, UL Slow-Blow or IEC 127-2/111 Time-lag 19.999 V, 100.0 V Input resistance 13 1 M 1 M 1 M 1 M 100/115Vac 40mA, UL Slow-Blow or IEC 127-2/111 Time-lag ADD-ON OPTIONS PART Bias current 50 pA 50 pA 10 pA 5 pA 1 pA 230Vac 20mA, UL Slow-Blow or IEC 127-2/111 Time-lag 230 V ac Input Power Add suffix-C1 Maximum input 55 mA 250 Vp 250 Vp 250 Vp 250 Vp 100 V ac Input Power Add suffix-C5 24 V ac Input Power (not CE approved) Add suffix-C8 5 V dc (for 205-A and 205-P only) Add suffix-C3 ANALOG INPUT / 205-A ELECTRICAL SAFETY CLASSIFICATION 7-32 V dc (for 205-A and 205-P only) Add suffix-C2 Green LED display (instead of Red) Add suffix- Range 199.9 mV 1.999 V 19.99 V 100.0 V Installation Category CAT I per EN61010-1 25 x 75 mm bezel adaptor Add suffixTP2 Input resistance 1 G 1.1 M 1.0 M 1.0 M Pollution Degree 2 per EN61010-1 3/64 DIN to 1/8 DIN bezel adaptor Add suffixTP3 Bias current 50 pA 5 pA 1 pA 1 pA Ordering Example: 205-P-C1 (205-P unit w/ 230 Vac) Class of Equipment I per EN61010-1 Maximum input 100 Vp 100 Vp 100 Vp 100 Vp TRANSMITTER EXCITATION SUPPLY / 205-E Return Requests/Inquiries NOISE REJECTION Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department. Output voltage Selected for 10 or 24 V dc BEFORE RETURNING ANY PRODUCT(S) TO NEWPORT, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM NEWPORTS CUSTOMER SERVICE DEPARTMENT NMR, sig hi to sig lo 56 dB, 50/60 Hz Output current, max 30 mA 10 V, 20 mA 24 V (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on CMR, sig lo to pwr gnd 120 dB, DC to 60 Hz the outside of the return package and on any correspondence. Line regulation 0.01% / V of ac power MODEL 205-P, 205-E The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent CMV, sig lo to pwr gnd Dielectric strength to 1500V transient Load regulation 0.5% breakage in transit. per 260 Volt RMS or DC working Tempco 0.02% / C FOR WARRANTY RETURNS, please have the FOR NON-WARRANTY REPAIRS, consult following information available BEFORE voltage. NEWPORT for current repair charges. Have the and 205-A Ripple at 50/60 Hz 0.01% contacting NEWPORT: following information available BEFORE CMV, sig lo to dig return 0 volts contacting NEWPORT: 1. P.O. number under which the product was PURCHASED, (205-A) 1. P.O. number to cover the COST of the repair, 2. Model and serial number of the product under 2. Model and serial number of product, and DISPLAY warranty, and 3. Repair instructions and/or specific problems 3 1/2 DIGIT MINI-SIZE PROCESS METER (205-P) 3. Repair instructions and/or specific problems relative to the product. relative to the product. ACCURACY AT 25 C / DISPLAY 1 PROCESS WITH ISOLATED EXCITATION (205-E) Type 3 /2 digit, 7-segment, red or green LED NEWPORTs policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. Height 14.2 mm (0.56 in.) DC VOLTAGE INPUT (205-A) NEWPORT is a registered trademark of NEWPORT Electronics, Inc. Maximum error 0.05% of reading 1 count Copyright 2005 NEWPORT Electronics, Inc. All rights reserved. Symbols -1.8.8.8 This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium Display range 1999 Overrange Indication Three least-significant digits blank For immediate technical or application assistance please call: or machine-readable form, in whole or in part, without prior written consent of NEWPORT Electronics, Inc. Span adjustment (205-P & -E) 0-2000 counts Span tempco 0.02% of reading/C ENVIRONMENTAL Warranty/Disclaimer Zero adjustment (205-P & -E) -1500 to +500 counts with zero input Newport Electronics, Inc. NEWPORT Electronics, Inc. warrants this unit to be free of defects in materials and Zero tempco (205-P & -E) 0.01% of offset 0.2 counts/C 2229 South Yale Street Santa Ana, CA 92704 U.S.A. workmanship for a period of one (1) year from the date of purchase. In addition to Operating temperature Full-scale step response 1 second TEL: (714) 540-4914 FAX: (203) 968-7311 NEWPORTs standard warranty period, NEWPORT Electronics will extend the warranty 205-E 0C to 50C (32F to 122F) Toll Free: 1-800-639-7678 www.newportUS.com e-mail:info newportUS.com Warmup 30 minutes period for one (1) additional year if the warranty card enclosed with each instrument is ISO 9001 Certified Operating temperature returned to NEWPORT. Reading rate 2.5 / second 205-P & 205-A 0C to 60C (32F to 140F) Newport Technologies, Inc. Overrange indication Three least-significant digits blank If the unit should malfunction, it must be returned to the factory for evaluation. 976 Bergar Laval (Quebec) H7L 5A1 Canada NEWPORTs Customer Service Department will issue an Authorized Return (AR) Storage temperature -40C to +85C (-40F to 185F) TEL: (514) 335-3183 FAX: (514) 856-6886 number immediately upon phone or written request. Upon examination by NEWPORT, if Relative humidity 95% at 40C (104F) (non-condensing) Toll Free: 1-800-639-7678 www.newport.ca e-mail:info newport.ca the unit is found to be defective it will be repaired or replaced at no charge. POWER OPTIONS / 205-E NEWPORTs WARRANTY does not apply to defects resulting from any action of the Newport Electronics, Ltd. purchaser, including but not limited to mishandling, improper interfacing, operation One Omega Drive River Bend Technology Centre outside of design limits, improper repair, or unauthorized modification. This WARRANTY MECHANICAL Voltage 115/230 Vac 15% Northbank, Irlam Manchester M44 5BD United Kingdom is VOID if the unit shows evidence of having been tampered with or shows evidence of Tel: +44 161 777 6611 FAX: +44 161 777 6622 Frequency 50-60Hz being damaged as a result of excessive corrosion or current, heat, moisture or Toll Free: 0800 488 488 www.newportuk.co.uk e-mail:sales newportuk.co.uk Case type 3/64 DIN (2472-100) vibration improper specification misapplication misuse or other operating conditions Power 3.5W max. outside of NEWPORTs control. Components which wear are not warranted, including Newport Electronics B.V. Bezel 24 x 72 mm (0.94 x 2.83 in) Voltage options with same but not limited to contact points, fuses, and triacs. Postbus 8034 1180 LA Amstelveen The Netherlands 3 Panel cutout /64 DIN 22.2 x 68 mm (0.87 x 2.68 in) power and frequency. TEL: +31 20 3472121 FAX: +31 20 6434643 NEWPORT is pleased to offer suggestions on the use of its various Toll Free: 0800 0993344 www.newport.nl e-mail: info newport.nl Panel Thickness 0.8 mm (0.03 in) min. -C5 100Vac 15% (36mA max.) products. However, NEWPORT neither assumes responsibility for any 6.4 mm (0.25 in) max. omissions or errors nor assumes liability for any damages that result -C8 24Vac 10% (145mA max.) Newport Electronics spol s.r.o. from the use of its products in accordance with information provided Frystatska 184, 733 01 Karvin Czech Republic Depth behind bezel, by NEWPORT, either verbal or written. NEWPORT warrants only that TEL: +420 59 6311899 FAX: +420 59 6311114 with connector 120 mm (4.72 in) the parts manufactured by it will be as specified and free of defects. Toll Free: 0800-1-66342 www.newport.cz e-mail: info newport.cz POWER OPTIONS / 205-P & 205-A NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF Weight 200 g (7 oz) Newport Electronics GmbH ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF Case material 94V-1 UL-rated thermoplastic Daimlerstrasse 26 D-75392 Deckenpfronn Germany TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY Voltage 115/230 Vac 15% TEL: 49 7056 9398-0 FAX: 49 7056 9398-29 OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Toll Free: 0800 / 6397678 www.newport.de e-mail: sales newport.de Frequency 50-60Hz ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of Power 2.5W max. Newport Electronique S.A.R.L. It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that NEWPORT with respect to this order, whether based on contract, 11, rue Jacques Cartier 78280 Guyancourt France Voltage options with same apply. NEWPORT is constantly pursuing certification of its products to the European New warranty, negligence, indemnification, strict liability or otherwise, TEL: +33 1 61 37 29 00 FAX: +33 1 30 57 54 27 shall not exceed the purchase price of the component upon which Approach Directives. NEWPORT will add the CE mark to every appropriate device upon power and frequency. Toll Free: 0800 466 342 www.newport.fr e-mail: sales newport.fr liability is based. In no event shall NEWPORT be liable for certification. AC -C5 100Vac 15% (36mA max.) consequential, incidental or special damages. Mexico and Latin America The information contained in this document is believed to be correct but NEWPORT -C8 24Vac 10% (133mA max.) FAX: 001 (203) 359-7807 CONDITIONS: Equipment sold by NEWPORT is not intended to be used, nor shall it be Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter En Espaol: 001 (203) 359-7803 DC* -C2 7-32 Vdc (100mA max.)* used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear specifications without notice. installation or activity or (2) in medical applications or used on humans. Should any -C3 5 Vdc (75mA max.)* WARNING: These products are not designed for use in, and should not be used for, patient Product(s) be used in or with any nuclear installation or activity, medical application, or * External Supply must meet safety Agency Approval for safety DC connected applications. used on humans, or misused in any way, NEWPORT assumes no responsibility as set output. (Equipment CLASS I/II, CAT I min., Double Insulation) forth in our basic WARRANTY / DISCLAIMER language, and additionally purchaser will Caution, risk of danger. This device is marked with the international caution indemnify NEWPORT and hold NEWPORT harmless from any liability or damage symbol. It is important to read the Setup Guide before installing or commissioning whatsoever arising out of the use of the Product(s) in such a manner. 10888ML-03 H/0305 this device as it contains important information relating to safety and EMC.