Strain Meter / Controller Strain Meter / Controller The INFS strain gage meter is a microprocessor- based indicator/ controller with enhanced features that allow you to easily configure the unit for virtually any application. It is compatible with most strain gage sensors such as load cells and pressure transducers. NEWPORT PRODUCT INFO MANUAL - PDF Version Shown with LC101 Series Load Cell QUICKSTART Sold Separately OPTIONS & ADDENDUMS SOFTWARE MECHANICAL PRICE REQUIRES ADOBE ACROBAT - HELP INFS 6 Digits Optional Split Meter System Four Isolated Open Collector Outputs Wide Selection of dc Voltage and Current Ranges Ratiometric Inputs Tare 1.5 to 11 and 24 Vdc Sensor Excitation Peak and Valley Detection and Memory Large Digital Offset Capabilities Enabling Easy Scaling in Engineering Units Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Applied For) Selectable Decimal Point and Read Rates of up to 13 Readings/Sec Configurable Via Front Pushbuttons or Via RS-232 or RS-485 OPTIONS Isolated Dual 7 Amp Form C Relays Isolated Parallel BCD Output Isolated Analog Output of 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc and 4-20 mA dc Isolated Serial RS-232 Isolated RS-485, Addressable up to 199 Units The INFINITY strain gage meter can be configured, via the five front-panel pushbuttons and/or the optional serial communications boards, to accept any of a variety of dc voltage ranges (some ranges plus unipolar or bipolar are first selected via a jumper located at the top of the instrument housing) and display them in engineering units.Strain Meter / Controller The INFW scale meter offers the same features as the INFS strain meter, plus it is easily integrated into your data acquisition systems, PLCs or other computer-controlled systems with the optional inputs. Other features include dual relay of BCD output, isolated analog output, RS-232 or RS-484 serial communications options, auto or sequential tare, class selection, and display of units of measure. Self-diagnostics are performed automatically on power-up. These meters provide both software and hardware lockout configurations which let you define the parameters, from setpoint adjustment to total reprogramming. Users can scale and offset their input signal into any engineering units desired. This is accomplished by the use of an exclusive two-data point method of scale and offset that eliminates the signal errors transmitted from a sensor. The meter provides a choice of sensor excitations of 1.5 to 11 Vdc or 24 Vdc for sensors such as load cells, strain gages, and pressure transducers. INFZS Split Meter with remote display Low Range Constant Moment Beam Load Cell with 4-Direction Overload Stops SPECIFICATIONS Accuracy: 0.005% rdg Span Temperature Coefficient: 15 ppm/C Step Response: 1 sec to 9.9% Warm-up to Rated Accuracy: 50 min Operating Ambient: 0 to 50C (32 to 122F), 95%RH, non-condensing Storage Ambient: -40 to 85C (-40 to 185F) Power: 115 or 230 Vac, 49-400 Hz 10 to 32 Vdc Power Consumption: 6 W nominal, 10 W max. Normal Mode Rejection: 60 dB Common Mode Rejection: 120 dB Common Mode Voltage: 1500 V peak per Hv test Conversion: dual-slope technique Resolution: 15-bit Reading Rate: 3/sec or 13/sec, 60 Hz 3/sec or 12/sec, 50 Hz Display: red or green 6-digit, 14-segment, 13.7 mm (0.54 ) 4 alarm indicators Dimensions: 48 H x 96 W x 165 D mm (1.89 x 3.78 x 6.5 ) Panel Cutout: 45 H x 92 W mm (1.772 x 3.622 ) 1/8 DIN Weight: 574 g (1.27 lb) TTL Outputs: four, isolated open collector rated 150 mA at 1 V sink, 30 V open BCD Output: isolated, tri-state, TTL/CMOS compatible external 5 V supply for isolated internal 5 V supply for non- isolated Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7A relays and dual 1 A relays Analog Output: 0-5 V/1-5 V/0-10 V/0-20 mA/4-20 mA, user selectable 354 Vp isolation 14-bit resolution 0.1% accuracy, 50 msec step response RS-232 Communications: 300/600/1200/2400/4800/9600/19.2k baud RJ11 4-wire connection complete program setup and message display capability programmable to transmit current display, alarm status, min/max, actual measured input value and status RS-485 Communications: 300/600/1200/2400/4800/9600/19.2k baud RJ12 6-wire connection addressable from 0 to 199 Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V, 0-10 V, 0-100 V, 50 mV, 500 mV, 5 V, 50 Current Input Ranges: 0-20 mA, 4-20 mA