Thermocouple Meters, Indicators/ Controllers 1 8 DIN Q2000-JKT Series U -300 to +1,999 or +9,999 Count Display Span U Thermocouple Types J, K, T U 3 or 4 Digit Display U 1 or 0.1 Resolution U Internal Reference Junction U Sensor-Break Detection U 1 or 0.1 mV/Count Linearized Analog output Q2000-KDC1 Meter shown smaller U LED or LCD Display than actual size. U Display Hold and Test U Screw-Terminal Barrier Strip The Q2/9000-J, Q2/9000-K and Q2/9000-T are Signal input and power connections are made via a indicator/controllers for thermocouple Types J, K and T, rear barrier terminal strip. The motherboard rear edge respectively. They are complete with linearization, connector provides access to hold and test, polarity, cold-junction compensation, and sensor-break clock, and the standard analog output and optional detection. Readout is in C or F with 1 or 0.1 analog outputs. resolution. Analog Output Options Power and Display Options A 1 mV/count or 0.1 mV/count (2 V full-scale) analog Six types of power supplies are available: 120 Vac, output is standard and is useful for driving a strip-chart 240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and recorder. An additional analog output can be provided isolated 26 to 56 Vdc. by an optional vertical plug-in board. Available output signals are 0 to 5 V dc, 0 to 10 V dc, 0 to 1 mA (source An LED display is standard, an LCD display is optional or sink), and 4 to 20 mA (source or sink). The top and and is recommended for viewing in bright ambient light. bottom of each output range can be scaled to fit a A NEMA 4 (IP65) splash-proof lens cover is available. user-selected display span. Thermocouple Inputs (J, K, T Series) Lead Burnout Q2000 Q9000 Code Q2000 Q9000 Accuracy Calibration Type Resist Sense Temp Range Temp Range * Res Res ( count) (Max) Current -40 to 0C: Note 1 -40 to -40.0 to JDC1 1C 0.1 C 0 to 277C: 1.2C J 760C 760.0C 277 to 760C: 0.5% rdg 500 -40 to 32F: Note 1 Iron - Constantan -40 to -40.0 to JDF1 1F 0.1 F 32 to 530F: 2.4F 1400F 999.9F 530 to 1400F: 0.5% rdg -40 to 0C: Note 2 -40 to -40.0 to KDC1 K 1C 0.1 C 0 to 277C: 1.8C 1260C 999.9C 395 277 to 1260C: 0.6% rdg 0.5 A CHROMEGA - -40 to 32F: Note 2 -40 to -40.0 to KDF1 ALOMEGA 1F 0.1 F 32 to 530F: 3.0F 1999F 999.9F 530 to 1999F: 0.6% rdg -184 to -59C: 1.5% rdg -184 to -184.0 to TDC1 T 1C 0.1 C -59 to 93C: 1C 371C 371.0C 93 to 371C: 0.6% rdg 200 Copper - -300 to -75F: 1.5% rdg -300 to -300.0 to TDF1 Constantan 1F 0.1 F -75 to 200F: 1.5F 700F 700.0F 200 to 700F: 0.5% rdg Notes 1: -40 to 0C: (0.95C -0.083T) (1.2C + 0.11T) -40 to 32F: (0.5F -0.083(T - 32F)) + 1.9F 2: -40 to 0C: (0.35C -0.075T) (1.35C + 0.1T) -40 to 32F: (1.65F -0.091T) (1.9F + 0.012T) 1 Ordering Example: Q2101-KDC1, 3 2 digit, LCD, 120 Vac power, 1C/count, dual setpoint (10 A relay), Type K -40 to 1260C range. 1Zero tempco (cold-junction error): Control Output Options Common Mode 0.06 deg/deg Additional outputs can be Voltage: 1500 Vp test (354 Vp per Span tempco, 10C to 40C: 0.01% provided by a horizontal upper board. IEC spacing) of reading/C Available options include single- Rejection: 120 dB with 250 ohm setpoint control with one imbalance Analog-to-Digital Conversion 10 A relay, dual-setpoint control Environmental Input configuration: Single-ended SIG with two 10 A relays, 4-20 mA HI (TC +) lead connected to SIG GND Operating Temperature: 0 to 60C proportional control (source or sink), through 10ohm (32 to 140F) time-proportional 2 A solid-state Technique: Dual slope, average value Storage Temperature: -40 to 85C relay control, and isolated, parallel Signal Integration Period: 100 ms, (-40 to 185F) BCD output. nominal Humidity: 95% RH, non-condensing Reading Rate: 2.5/s, nominal 40C (104F) Specifications Display Mechanical Analog Input Symbols: -1.8.8.8 (Q2000) Bezel: 96 W x 48 H x 8 mm D TC types: J, K, T 8.8.8.8 (Q9000) (3.78 x 1.89 x 0.31 ) Calibration: To IPTS-68, as published LED: Red, 14.2 mm (0.56 ), 7-segment Depth Behind Bezel: 139.8 mm (5.50 ) in NIST monograph 125 (March 1974), ASTM E130-72 or ASA C96.2-1973 LCD: 12.7 mm (0.50 ), 7-segment Panel Cutout: 92 W x 45 mm H (3.62 x 1.77 ) Configuration: Single-ended (-TC lead Power connected to ANA GND) Weight: 17 oz (480 g) AC Models: 120, 240 or 24 Vac, Input resistance: 100 Mohm Case Material: 94V-0 UL-rated +10/ -15%, 49 to 440 Hz polycarbonate Sensor-break detection: 400 nA DC Models: 5 Vdc 5%, 9 to 32 Vdc current source or 26 to 56 Vdc isolated to 300 Vp Max lead resistance for rated accuracy: 500 ohm (type J), 395 ohm (type K), 200 ohm (type T) To Order Visit newportUS.com/q2000a-j for Pricing and Details Model No. Description Q2 3-Digit for 1999 Count Q9 4-Digit for 9999 Count 0 0 0 -X A. Power and Display 0 LED 120 Vac (50/60 Hz) 1 LCD 120 Vac (50/60 Hz) (Q2000 only) 2 LED 240 Vac (50/60 Hz) 3 LCD 240 Vac (50/60 Hz) (Q2000 only) 4 LED 9 to 32 Vdc, isolated 5 LCD 9 to 32 Vdc, isolated (Q2000 only) 6 LED 5 Vdc 7 LCD 5 Vdc (Q2000 only) 8 LED 24 Vac 9 LCD 24 Vac (Q2000 only) A LED 26 to 56 Vdc, isolated B LCD 26 to 56 Vdc, isolated (Q2000 only) B. Analog Outputs 0 1 mV/count (Q2000) or 0.1 mV (Q9000) (supplied on all units) 1 0 to 5 Vdc 2 0 to 10 Vdc 3 0 to 1 mA (internally driven) 4 4 to 20 mA (internally driven) 5 4 to 20 mA (externally driven) 6 4 to 20 mA (isolated) C. Control Outputs 0 None 1 Dual setpoint, 10 A relay (SPDT) 2 Proportional 4 to 20 mA 3 Proportional/time proportioning, 2 A relay 4 Parallel BCD, isolated 5 Single setpoint, 10 A relay (SPDT) D. Signal Conditioner Inputs -J(*) Type J thermocouple -K(*) Type K thermocouple -T(*) Type T thermocouple Additional Options ,G Green LED display ,BL Lens without Newport logo in lieu of standard lens * Refer to chart on previous page for thermocouple code. 1 Ordering Example: Q2005-KDF1, 3 2 digit, red LED, 120 Vac power, 1 mv/count, single setpoint 10 A relay, Type K -40 to 1999F range Q9401-JDC1, 4 digit, red LED, 9 to 32 Vdc power, 0.1 mv/count, dual setpoint 10 A relay, Type J -40 to 760C range. 2