MAB MKP box with radial or cable terminals AC-Motor run applications MABA01 and MABA02 EN60252-1 IMQ approved all types UL810 construction only approved, execution upon request Main applications Self inductance Motor run capacitor, general purpose AC applications, medium-low 1nH/mm of capacitor pitch and leads length used for connection power switching capacitor for industrial and motor speed controls, Maximum pulse rise time V/s electronic ballasts and SMPS The pulse characteristic Ko depends on the voltage waveform.In any Dielectric case the value given in the article table must not be overcome Polypropylene Dissipation factor (DF), max. -4 Electrodes tg x10 , measured at 25 5C, 1 kHz Vacuum deposited metal layers Cn 2.2 F 2.2 F < Cn 10 F 10 F < Cn 20 F Cn > 20 F Coating 6 10 12 15 Solvent resistant plastic case (UL 94 V-1 minimum) with resin sealing (UL 94 V-0). Flame retardant execution. Insulation resistance (R ) INS In conformity with: Measured between terminals, at 25C, after 1 minute of - glow wire tests in accordance with IEC 60335-1 electrification at 100Vdc: - ball pressure test in accordance with IEC 60695-10-2 R 10000s for Cn <1 F (typical value 30000s) INS Please refer to the article tables for the official approval tests R 3000s for Cn 1F (typical value 10000s) INS references Test voltage between terminals (Ut) Construction 1,6xUr(AC) applied for 1 minute at 255C Extended metallized film (refer to General Technical Information) 2,0xUr(AC) applied for 1 minute at 255C for EN60252-1 2011 approved ratings Terminals Tinned copper wire (lead-free), insulated tinned copper (lead- free) Test voltage between terminals and case (Utc) or stranded insulated tinned copper (lead-free) wire leads. Insulated 3kV 5060Hz applied for 60s at 25 5C leads available for box size 1018,526,5 mm. Cable leads execution Protection class not suitable for high Irms switching use S0 Terminals code Life expectancy class S for 51mm length tinned copper leads , L for 305mm length tinned In accordance with EN60252-1: copper leads, C for tinned copper insulated wire, M for stranded Class A: 30000 h Class B: 10000 h Class C: 3000 h Class D: 1000 h insulated tinned copper lead Please refer to the article table for each series ratings and life Reference standard expectancy class IEC 60068, EN 60252-1 (2011)+ A1 (2013), SEV1029, CSA 22.2 n.190 Damp heat test (steady state) and UL810 (construction only), IEC 60335-1, RoHS compliant Test conditions: Approvals Temperature = +40 2C Please refer to the article tables. Construction only UL810 (file Relative humidity =93 2% E192977) and CSA22.2 N.190 approved, execution available upon Test duration = 56 days request Performance: Climatic category Capacitance change 2% 40/100/56 (IEC 60068/1), GPD (DIN40040) DF change 0.0010 at 1kHz for Cr < 15F 25/085/56 (IEC 60068/1), HPF (DIN40040) for approvals reference DF change 0.0015 at 1kHz for Cr 15F Please refer also to paragraph C10 (humid ambient) of the General IR 50% of initial limit value Technical Information Endurance test reference: EN60252-1 (2011) Operating temperature range (case) Test conditions: -40...+100C Applied voltage and temperature: 1,25 x Ur AC at +85C -25...+85C for approvals reference Test duration: Nominal Capacitance (Cn) F 200h for class D: 1000 hours expected life, continuous operation 0,1F to 40F. Refer to article table 600h for class C: 3000 hours expected life, continuous operation 2000h for class B: 10000 hours expected life, continuous operation Capacitance tolerance (at 1kHz) 6000h for class A: 30000 hours expected life, continuous operation 10% (code=K), 5% (code=J), 2.5% (code= H) and 20% (code=M). Performance: Other tolerances upon request Capacitance change 3% 1 piece > 3% on 21 tested for EN60252-1 Capacitance temperature coefficient (2011) approved ratings Refer to General Technical Information Resistance to soldering heat test Long term stability (at 1kHz) Test conditions: Capacitance variation 1% after a period of 2 years at standard Solder bath temperature= +260 5C environmental conditions Dipping time (with heat screen)= 10 1s Rated voltage (Ur) Performance: 160 600Vac 5060Hz (370 1200Vdc). Please refer to the article table Capacitance change 1% Category voltage (Uc) DF change 0.0010 at 1kHz Uc= 0,8 x Ur at +100C (for +85C < T +100C, Ur must be decreased R 50% of initial limit value INS 1,5% for every C exceeding +85C) Uc=Ur at +85C for approvals reference 1 Ed. 04 Rev. 00 09.2018MAB MKP box with radial or cable terminals AC-Motor run applications MABA01 and MABA02 EN60252-1 IMQ approved all types UL810 construction only approved, execution upon request Note: standard cables length up to 80mm longer leads available upon request special tinned copper wire terminals length available upon request MABA05 article table 500V 5060Hz, +85C,continuous service, class B (10000 h) 600V 5060Hz, +85C,continuous service, class C (3000 h) 1200Vdc Upk= 1500Vdc Construction only UL810 (file E192977) and CSA22.2 N.190 approved execution available upon request (1) Cn Dimensions (mm) du/dt K ICEL CODE 0 2 F B H L d P V/s V /s - 0,1 7 16 26,5 0,8 22,5 175 296000 MABA053100*G 0,12 8,5 17 26,5 0,8 22,5 175 296000 MABA053120*G 0,15 8,5 17 26,5 0,8 22,5 175 296000 MABA053150*G 0,18 10 18,5 26,5 0,8 22,5 175 296000 MABA053180*G 0,22 11 20 26,5 0,8 22,5 175 296000 MABA053220*G 0,22 11 20 32 0,8 27,5 145 245000 MABA053220*H 0,27 13 22 26,5 0,8 22,5 175 296000 MABA053270*G 0,27 11 20 32 0,8 27,5 145 245000 MABA053270*H 0,33 13 22 32 0,8 27,5 145 245000 MABA053330*H 0,39 13 22 32 0,8 27,5 145 245000 MABA053390*H 0,47 14 28 32 0,8 27,5 145 245000 MABA053470*H 0,56 14 28 32 0,8 27,5 145 245000 MABA053560*H 0,68 14 28 32 0,8 27,5 145 245000 MABA053680*H 0,75 18 33 32 0,8 27,5 145 245000 MABA053750*H 0,82 18 33 32 0,8 27,5 145 245000 MABA053820*H 1 17 28 42,5 1 37,5 90 152000 MABA054100*J 1,2 22 30 42,5 1 37,5 90 152000 MABA054120*J 1,5 22 30 42,5 1 37,5 90 152000 MABA054150*J 1,8 28 37 42,5 1 37,5 90 152000 MABA054180*J 2 28 37 42,5 1 37,5 90 152000 MABA054200*J 2,2 28 37 42,5 1 37,5 90 152000 MABA054220*J 2,5 28 37 42,5 1 37,5 90 152000 MABA054250*J 2,7 30 45 42,5 1 37,5 90 152000 MABA054270*J 3 30 45 42,5 1 37,5 90 152000 MABA054300*J 3,3 30 45 42,5 1 37,5 90 152000 MABA054330*J 3,5 30 45 42,5 1 37,5 90 152000 MABA054350*J 4 35 50 42 1,2 37,5 90 152000 MABA054400*J 4,3 35 50 42 1,2 37,5 90 152000 MABA054430*J (1) Change the * symbol with the needed capacitance tolerance code: H=2.5%, J=5%, K=10%, M=20% and the symbol with the needed leads execution (S, L, M or C) 2 Ed. 04 Rev. 00 09.2018