PPB MKP with double side met. current carriers box with radial terminals snubber high pulse applications high current high frequency Main applications Insulation resistance (R ) INS Snubber, SCR commutating circuits, electronic ballasts, protection circuits Measured between terminals, at 25C, after 1 minute of electrification at in SMPSs, defl ectors circuits in TV sets, high voltage, high current and high 100Vdc pulse operation up to very high operating frequencies Cn R INS Dielectric 0.33 F 100 G Polypropylene > 0.33 F 30000 s Electrodes Vacuum deposited metal layers Test voltage between terminals (Ut) Coating 1,6xUr (DC) or 1,5xUrac (AC) applied for 2s at 255C (1 minute for type Solvent resistant plastic case with resin sealing (UL 94 V-0). Flame retardant test) execution Damp heat test (steady state) Construction Test conditions: Extended double side metallized carrier film, internal series connection Temperature = +40 2C and metallized film for Ur 630 VDC (refer to General Technical Relative humidity =93 2% Information) Test duration = 56 days Terminals Performance: Capacitance change 2% Tinned copper wire (lead-free) DF change 0.0010 at 10kHz for Cn 1F Reference standard DF change 0.0010 at 1kHz for Cn > 1F IEC 60384/16, IEC 60384/17, IEC 60068, RoHS compliant R 50% of initial limit value INS Climatic category Endurance test (DC) 55/100/56 (IEC 60068/1), FMD (DIN40040) Test conditions: Operating temperature range (case) Temperature= +852C -55...+105C Test duration= 2000h Voltage applied=1,25xUr(DC) Nominal Capacitance (Cn) F Performance: 0,001F to 15F, in compliance with IEC 60063, E6 series. Refer to article Capacitance change 1% table DF change 0.0010 at 10kHz for Cn 1F Capacitance tolerance (at 1kHz) DF change 0.0010 at 1kHz for Cn > 1F 10% (code=K), 5% (code=J) and 20% (code=M). Other tolerances R 50% of initial limit value INS upon request AC (50/60Hz) Endurance test (for Ur>400Vdc ratings only) Capacitance temperature coefficient Test conditions: Refer to General Technical Information Temperature= +852C Long term stability (at 1kHz) Test duration= 2000h Capacitance variation 0.5% after a period of 2 years at standard Voltage applied=1,25xUr(AC) environmental conditions Performance: Capacitance change 5% Rated voltage (Ur) (Vdc) at 85C DF change 0.0010 at 10kHz for Cn 1F 250, 400, 630, 1000, 1600, 2000 Vdc DF change 0.0010 at 1kHz for Cn > 1F Permissible AC voltage at 60Hz (Vac) R 50% of initial limit value INS 160, 200, 400, 600, 650, 700 Vac Resistance to soldering heat test Category voltage (Uc) Test conditions: Uc=Ur at +85C Uc=0,8xUr (0,7xPermissible AC voltage) at +100C Solder bath temperature= +2605C Temperature de-rated voltage Dipping time (with heat screen)= 101s For T> +85C, Ur must be decreased 1,25% (permissible AC voltage must Performance: be decreased 2,25%) for every C exceeding +85C Capacitance change 1% DF change 0.0010 at 10kHz for Cn 1F Self inductance DF change 0.0010 at 1kHz for Cn > 1F 1nH/mm of capacitor pitch R 50% of initial limit value INS Maximum pulse rise time V/s Reliability (MIL HDB 217) Refer to article table. The pulse characteristic Ko depends on the voltage waveform. In any case the value given in the article table must not be Application conditions: exceeded Applied voltage= 0,5 x Ur(DC) Temperature= +402C Dissipation factor (DF), max. -9 -4 Failure rate: (1FIT=1x10 failures/components x hours) tg x10 , measured at 25 5C 2FIT for Ur 400Vdc 1FIT for Ur > 400Vdc Freq. Cn 0.1 F 0.1 F < Cn 1 F Cn > 1 F Failure criteria (DIN44122): 1kHz 5 4 5 Capacitance change > 10% 10kHz 5 6 - DF change > 2 x initial value R < 0,005 x initial limit value 100kHz 16 - - INS Short or open circuit 10.1 Ed. 04 Rev. 00 09.2018PPB MKP with double side met. current carriers box with radial terminals snubber high pulse applications high current high frequency PPB article table (different values available upon request) (3) (1) Voltage at +85C Cn Dimensions (mm) du/dt K ICEL CODE 0 2 Ur (Vdc) Urms (Vac) F B H L P d V/s V /s - 250 160 0,047 5 11 18 15 0,8 560 280000 PPB1252470*E 250 160 0,068 6 12 18 15 0,8 560 280000 PPB1252680*E 250 160 0,1 7,5 13,5 18 15 0,8 560 280000 PPB1253100*E 250 160 0,15 8,5 14,5 18 15 0,8 560 280000 PPB1253150*E 250 160 0,22 10 16 18 15 0,8 560 280000 PPB1253220*E 250 160 0,22 6 15 26,5 22,5 0,8 320 160000 PPB1253220*G 250 160 0,33 8,5 17 26,5 22,5 0,8 320 160000 PPB1253330*G 250 160 0,47 10 18,5 26,5 22,5 0,8 320 160000 PPB1253470*G 250 160 0,68 11 20 26,5 22,5 0,8 320 160000 PPB1253680*G 250 160 0,68 11 20 32 27,5 0,8 240 120000 PPB1253680*H 250 160 1 13 22 26,5 22,5 0,8 320 160000 PPB1254100*G 250 160 1 11 20 32 27,5 0,8 240 120000 PPB1254100*H 250 160 1,5 15 24,5 32 27,5 0,8 240 120000 PPB1254150*H 250 160 2,2 14 28 32 27,5 0,8 240 120000 PPB1254220*H 250 160 2,2 17 28 42,5 37,5 1 170 85000 PPB1254220*J 250 160 3,3 22 30 42,5 37,5 1 170 85000 PPB1254330*J 250 160 4,7 22 30 42,5 37,5 1 170 85000 PPB1254470*J 250 160 6,8 28 37 42,5 37,5 1 170 85000 PPB1254680*J 250 160 10 30 45 42,5 37,5 1,2 170 85000 PPB1255100*J 250 160 15 35 50 42 37,5 1,2 170 85000 PPB1255150*J (2) 400 250 0,033 5 11 18 15 0,8 910 728000 PPB1402330*E (2) 400 250 0,047 6 12 18 15 0,8 910 728000 PPB1402470*E (2) 400 250 0,068 7,5 13,5 18 15 0,8 910 728000 PPB1402680*E (2) 400 250 0,1 8,5 14,5 18 15 0,8 910 728000 PPB1403100*E (2) 400 250 0,15 10 16 18 15 0,8 910 728000 PPB1403150*E (2) 400 250 0,15 7 16 26,5 22,5 0,8 520 416000 PPB1403150*G (2) 400 250 0,22 10 18,5 26,5 22,5 0,8 520 416000 PPB1403220*G (2) 400 250 0,33 11 20 26,5 22,5 0,8 520 416000 PPB1403330*G (2) 400 250 0,33 9 17 32 27,5 0,8 400 320000 PPB1403330*H (2) 400 250 0,47 13 22 26,5 22,5 0,8 520 416000 PPB1403470*G (2) 400 250 0,47 13 22 32 27,5 0,8 400 320000 PPB1403470*H (2) 400 250 0,68 15 24,5 32 27,5 0,8 400 320000 PPB1403680*H (2) 400 250 1 18 33 32 27,5 1 400 320000 PPB1404100*H (2) 400 250 1 17 28 42,5 37,5 1 280 224000 PPB1404100*J (2) 400 250 1,5 17 28 42,5 37,5 1 280 224000 PPB1404150*J (2) 400 250 2,2 22 30 42,5 37,5 1 280 224000 PPB1404220*J (2) 400 250 3,3 28 37 42,5 37,5 1 280 224000 PPB1404330*J (1) Change the * symbol with the needed Cap. tol. code: J=5%, K=10%, M=20% and the symbol with S for 5mm or L for 30 mm lead length (2) Not suitable for across the line application (3) Pulse endurance test not applicable 10.2 Ed. 04 Rev. 00 09.2018