18D Pneumatic pressure switch electromechanically actuated -1 ... 30 bar, G1/4, 1/4 NPT and flange Microswitch with gold plated contacts High number of switching cycles Vibration resistant to 15 g Conforms to Low Voltage Directive 2006/95/EG Intrinsically safe operation Technichal features Medium: Repeatability: Electrical connection: Materials: For neutral, gaseous and liquid 3% for vacuum DIN EN 175301-803 (DIN 43650) Housing: aluminium (brass) fluids, non-combustible (Special 4% of final value form A or M12 x 1 IEC 947-5-2 Sealing: NBR/FPM versions for water application) (depending on regulating Fluid-/Ambient temperature: Operation: pressure) -10 ... +85C (NBR) Diaphragm Switching element: 0 ... +80C (FPM) Operating pressure range: Microswitch with gold plated Air supply must be dry enough -1 ... 30 bar contacts to avoid ice formation at Operating viscosity: Mounting position: temperatures below +2C. 2 Up to 1000 mm /s Optional Switching pressure difference: Degree of protection: Fixed IP65 for DIN EN 175301-803 (DIN 43650) form A IP67 for M12 x 1 Technical data Electrical connection acc. to DIN EN 175301-803, form A Pressure Switching pressure difference- Max. over Switching Materials Weight Dimension Model Symbol Port size range *1) Lower range Upper range pressure *2) cycles pressure sensor (bar) (bar) (bar) (bar) (1/min) Housing Sealing (kg) No. -1 ... 0 G1/4 0,15 0,18 80 100 AL FPM *3) 0,2 1 0880100 -1 ... 1 G1/4 0,25 0,35 80 100 AL FPM *3) 0,2 1 0880110 -1 ... 0 1/4 NPT 0,15 0,18 80 100 AL FPM *3) 0,2 1 0880120 -1 ... 0 G1/4 0,15 0,18 80 100 AL FPM *3) 0,2 1 0880126 *4) *6) -1 ... 0 Flange 0,15 0,18 80 100 AL FPM *3) 0,2 3 0881100 0,2 ... 2 G1/4 0,20 0,35 80 100 AL FPM *3) 0,2 1 0880200 0,2 ... 2 1/4 NPT 0,20 0,35 80 100 AL FPM 0,2 1 0880220 0,2 ... 4 G1/4 0,20 0,35 80 100 AL FPM 0,2 1 0880226 *4) *6) 0,2 ... 2 Flange 0,20 0,35 80 100 AL NBR 0,2 3 0881200 0,5 ... 8 G1/4 0,35 0,85 80 100 AL NBR 0,2 2 0880300 0,5 ... 8 1/4 NPT 0,35 0,85 80 100 AL NBR 0,2 2 0880320 0,5 ... 8 G1/4 0,35 0,85 80 100 AL FPM 0,2 2 0880326 *4) *6) 0,5 ... 8 Flange 0,35 0,85 80 100 AL NBR 0,2 3 0881300 1 ... 16 G1/4 0,40 1,20 80 100 AL NBR 0,2 2 0880400 1 ... 16 1/4 NPT 0,40 1,20 80 100 AL NBR 0,2 2 0880420 1 ... 16 G1/4 0,40 1,20 80 100 AL FPM 0,2 2 0880426 *4) *6) 1 ... 16 Flange 0,40 1,20 80 100 AL NBR 0,2 3 0881400 1 ... 30 G1/4 1,0 5,00 80 100 AL NBR 0,2 2 0880600 1 ... 30 1/4 NPT 1,0 5,00 80 100 AL NBR 0,2 2 0880620 *1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values *3) Static seal: O-ring (NBR) *4) LABS free *6) Plug 0570110 not included, please order separately. Our policy is one of continued research and development. We therefore reserve the right to amend, 12/13 1998-5249c N/en 5.11.001.01 without notice, the specifications given in this document. 2013 Norgren GmbH18D Electrical connection M12 x 1 nach IEC 947-5-2 - plug not included, max. allowable voltage 30 V Symbol Pressure Port size Switching pressure difference Max. over Switching Materials Weight Dimension Model range *1) Lower range Upper range pressure *2) cycles pressure sensor (bar) (bar) (bar) (bar) (1/min) Housing Sealing (kg) No. -1 ... 0 G1/4 0,15 0,18 80 100 AL FPM 0,2 1 0880149 *4), *5) -1 ... 0 G1/4 0,15 0,18 80 100 AL FPM 0,2 1 0880160 *4) 0,2 ... 2 G1/4 0,20 0,35 80 100 AL FPM 0,2 1 0880260 *4) 0,5 ... 8 G1/4 0,35 0,85 80 100 AL FPM 0,2 2 0880360 *4) 1 ... 16 G1/4 0,40 1,20 80 100 AL FPM 0,2 2 0880460 *4) 1 ... 30 G1/4 1,00 5,00 80 100 AL FPM 0,3 2 0880660 *4) -1 ... 0 Flange 0,15 0,18 80 100 AL FPM 0,2 3 0881160 *4) 0,2 ... 2 Flange 0,20 0,35 80 100 AL FPM 0,2 3 0881260 *4) 0,5 ... 8 Flange 0,35 0,85 80 100 AL FPM 0,2 3 0881360 *4) 1 ... 16 Flange 0,40 1,20 80 100 AL FPM 0,2 3 0881460 *4) *1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values *4) LABS free *5) Switching function reversed Versions for water applications Electrical connection acc. to DIN EN 175301-803, form A Symbol Pressure Switching pressure difference Max. over Switching Materials Weight Dimension Model Port size range *1) Lower range Upper range pressure *2) cycles pressure sensor (bar) (bar) (bar) (bar) (1/min) Housing Sealing (kg) No. 0,2 ... 2 G1/4 0,20 0,35 80 100 Messing FPM 0,2 1 0880219 0,2 ... 2 1/4 NPT 0,20 0,35 80 100 Messing FPM 0,2 1 0880240 0,5 ... 8 G1/4 0,35 0,85 80 100 Messing FPM 0,2 2 0880323 0,5 ... 8 1/4 NPT 0,35 0,85 80 100 Messing FPM 0,2 2 0880340 *1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values Accessories Pressure port Surge damper Cover Connector Connector M 12 x 1 Connector M 12 x 1 Reducing nipple (via adjustment 90 straight screw) Page 4 Page 4 Page 4 0574767 0574773 0554737 0570110 0523058 0523056 0523057 0523055 (brass) (brass) (2 m cable,4-core) (90without cable) (2 m cable, 4-core) (without cable) 0550083 0553258 0523053 0523052 (stainless steel) (stainless steel) (5 m cable,4-core) (5 m cable, 4-core) Our policy is one of continued research and development. We therefore reserve the right to amend, N/en 5.11.001.02 1998-5249c 12/13 without notice, the specifications given in this document. 2013 Norgren GmbH