Features R65 Series 10 Programmable Timing Modes + 2 Counting Modes 0.1 sec to 9,990 hr. Programmable Timing Range 1 to 99,900 Counting Range LCD Digital Display Programmable, DPDT, 10 Amp, AC or Thumbwheel Switches for Programming DC, Multifunctional, Digital Time Delay Relay/Counter. D46 ON NC NO A 2 1 4 S .320 (8.1) 2.830 (71.9) 3.150 (80.0) .640 (16.3) 1.760 (44.7) DPDT, 2 Form C DPDT, 2 Form C Sq. RESET External Control Switches** CONTROL CONTROL (COUNT) 1.880 (47.8) Sq. RETURN Electrical Specifications RETURN RESET Use Same For RESET 6 6 Contact 5 7 5 7 Rating: 10 Amps 30VDC or 277VAC, resistive 4 4 8 8 1/2 HP 250VAC 1/3 HP 120VAC Life: 100,000 operations at minimum rated load 3 3 9 9 Mechanical Life: 10,000,000 operations 2 2 10 10 1 11 1 11 Input Nominal Input voltage: 24 240V 15%, 50/60Hz AC or DC + + INPUT* INPUT* Nominal Power: See Chart Timing * Note input polarity for DC operation. For most reliable operation on AC, connect high side to + and low side to . Timing Ranges: 0.1 to 99.9 / 1 to 999 sec 0.1 to 99.9 / 1 to 999 min 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. ** IMPORTANT: A dry circuit switch is recommended. A dry circuit switch Timing Adjustments: Digital adjustment via thumbwheel switches is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay Tolerance: 0.1% 0.05 sec to function properly. Delta Time (for AC units add 1 cycle 60Hz): 0.1% 0.05 sec Repeatability: 0.1% 0.05 sec including first cycle of operation Reset Time (power interruption): 45mS, typ 60 mS, max Minimum Pulse Width, Control: 50mS Recycle Time: 45mS, typ 60mS, max AC or DC OPERATED Counting Max. Contact Maximum Count: 1 to 999 10 to 9,990 ( 10) 100 to 99,900 ( 100) Timing Nom Cur. Maximum Count Rate: 100 counts per second NTE Adj Count Contact Vltg Nom 28VDC Diag Type No. Minimum Pulse Width: Range Range Arr. AC/DC Power 120VAC No. Count (Control): 3mS R6511AD10 0.1 Sec 1 DPDT 24 1W 24V 10A D46 Reset: 3mS to to to 5W 120V 9,990 Hr. 99,900 240 10W 240V Available Counting Functions: Operate at preset count and release at preset count Protection Transient: yes ACCESSORIES Dielectric Strength Between Open Contacts: 1000V , 60Hz rms MOUNTING NTE Between All Other Conductors: 1500V , 60Hz STYLES DESCRIPTION TYPE NO. rms Environmental Characteristics SURFACE MOUNT 11PIN OCTAL R95104 Operating: 10C to +55C PANEL MOUNT 11PIN OCTAL R95119 Storage: 20C to +70C DIN RAIL MOUNT 11PIN OCTAL R95114 Weight DIN RAIL MOUNT 11PIN OCTAL R95182 Std: 4.3 oz (122 grams) approx. 70 NTE Electronics, Inc. Voice (973) 7485089 FAX (973) 7486224 R65 Series (Continued) Programming Switch Diagram A 2 1 4 S Function Select Timer/Counter Select Time Base Select Timer Mode: 001 to 999 Timer Base: A Delay On Operate .1S 0.1 to 99.9 Sec B Delay On Release S 1 to 999 Sec C Interval On D ControlOff Interval On .1M 0.1 to 99.9 Min E Recycle M 1 to 999 Min F Single Cycle G Control OnOff Interval On .1H 0.1 to 99.9 Hrs H Control OnOff Delay H 1 to 999 Hrs I Pulse 10H 10 to 9990 Hrs J Cumulative Delay On Operate Counter Select Counter Mode Select Counter Mode: CO Operate at Preset Count A, DJ Normal Count CR Release at Preset Count B Divide by 10 C Divide by 100 NOTE: With this setting, the relay would operate after a delay period of 214 seconds. Timer Function Descriptions started by momentary CONTROL input or poweron with CONTROL A. Delay On Operate on. Relay stays on for equal time interval, then turns off. RESET Output relay turned on at end of programmed time interval which is terminates timing and turns relay off. Turning RESET off does not started by CONTROL input or poweron with CONTROL on. Relay restart timing. turned off by RESET input until next cycle is started. With CONTROL on, turning RESET off restarts timing. G. Control OnOff Interval On (Watch Dog Timer) B. Delay On Release Output relay turned on and programmed time interval started of Output relay turned on with CONTROL input and remains on for restarted by chang of CONTROL input. RESET turns relay off and programmed time interval following removal of CONTROL. During time stops timing. Turning RESET off does not restart timing. interval after release of CONTROL, RESET turns relay off until cycle restarted with reapplication of CONTROL With CONTROL on, relay is H. Control OnOff Delay held off while RESET is activated. Output relay turned on at end of programmed timing interval which is started or restarted by charge of CONTROL input. If relay is on, trunoff C. Interval On of relay occurs at end of programmed time interval which is started or Output relay turned on for programmed time interval by CONTROL or restarted by charge of CONTROL input. RESET turns relay off and poweron with CONTROL on. RESET turns relay off until next cycle stops timing. Turning RESET off does not restart timing. is started, and does not restart timing when RESET is removed. I. Pulse D. ControlOff Interval On Output relay turned on at end of programmed time interval, which is Output relay turned on for programmed time interval by turnoff of started by CONTROL input, for 0.5 second duration, and continues in CONTROL. RESET truns relay off until next cycle is started, and does pulsed mode at programmed time interval with fixed 0.5 second not restart timing when RESET is removed. ontime. Turning CONTROL off turns relay off and stops timing. RESET turns relay off and inhibits operation. With CONTROL on, E. Recycle removal of RESET restarts timing. Output relay turned on at end of programmed time interval which is J. Cumulative Delay On Operate started by momentary CONTROL input or poweron with CONTROL Output relay turned on at completion of total accumulate CONTROL on. Relay stays on for equal time interval, then turns off and cycle is input duration equal to programmed time. Turning CONTROL off repeated on a freerunning basis until terminated by momentary before accumulation of programmed time results in measured time total RESET, turning relay off. With CONTROL on, turning RESET off being held until CONTROL is again turned on and total programmed restarts cycle. time value is reached. RESET input resets time value to zero and turns F. Single Cycle relay off if energized. Turning RESET off restarts timing if CONTROL Output relay turned on at end of programmed time interval which is is on. Counter Function Descriptions Operation is similar to CO (Operate at Preset Count) except relay turns CO. Operate at Preset Count Normal Mode off at preset count. After initializing by momentary activation of RESET input, each on/off signal at COUNT (CONTROL) input increments displayed count in upcounting manner from initial 000 value until preset count, set by CO or CR. Divideby10 Mode thumbwheel switches, is reached and output relay turns on. Additional Operation is as described previously, except count is incremented for inputs continue to increment displayed count. Continued counting past every 10 on/off input signals for a maximum presettable count of 9,990. maximum count (999) results in a wraparound effect to 000, followed by continued upcounting. Activation of RESET input turns relay off CO or CR. Divideby100 Mode and resets count to zero. Operation is as described previously, except count is incremented for CR. Release at Preset Count Normal Mode every 100 on/off input signals for a maximum presettable count of Initializing by momentary activation of RESET input turns relay on. 99,900. 71 NTE Electronics, Inc. Voice (973) 7485089 FAX (973) 7486224