Digital Panel Meters Industry Leading Performance...and Easy to Use DP16DPt Series shown actual size. DP8EPt Series shown actual size. U Fle xible Alarm DP32Pt, DP16Pt, and Programming DP8Pt Series U Remote Latc h Reset U A vailable with 2 Optional Mechanical Relays for Alarms and Isolated U High P erformance, Analog Output Extremely Versatile DP32Pt Series shown actual size. 1 1 U Off ered in 32, 16, and U Easy and Intuitive to Use 1 8 DIN Sizes indication is available. The two U Bright 3-Color ( RED, optional single pole double throw GREEN, and AMBER) The PLATINUM Series family of mechanical relays can be assigned 9 Segment LED, 4 or microprocessor-based digital panel to either or both alarm triggers. meters offer unparalleled flexibility 6 Digit Display with Wide Two annunciators and three display in process measurement. While colors can also be assigned to the Viewing Angle extremely powerful and versatile, alarm triggers. U High Accuracy Universal great care has gone into designing Inputs for Thermocouples, a product that is very easy to set-up The PLATINUM Series device and use. The automatic hardware features a large, 3-color, 9 segment RTDs, Thermistors, and configuration recognition eliminates programmable LED display with Process Voltage/Current the need for jumpers and allows the the capability to change color and/ U No J umpers to Set, Totally firmware to automatically simplify or change the state of designated Firmware Configurable itself, eliminating all menu options outputs every time an alarm is that do not apply to a specific triggered. The universal power U Automated Configuration configuration. supply accepts 90 to 240 Vac. The Recognition, Smart low voltage power option accepts Each unit allows the user to select Menu Flow 24 Vac or 12 to 36 Vdc. the input type from 9 thermocouple U Up to 20 Samples per types (J, K, T, E, R, S, B, C, and N), Embedded Ethernet and Second with 24-Bit ADC Pt RTDs (100, 500, or 1000 , with Serial Communications either 385, 392, or 3916 curve), U Standard USB, Optional Optional embedded ethernet on thermistors (2250 , 5K , and Ethernet and RS232/ 1 1 the 16 and 8 DIN models allow 10K ), DC voltage, or DC current RS485 with MODBUS the units to connect directly to an and strain. The bipolar voltage or Serial Communications ethernet network and transmit current inputs are fully scalable to data in standard TCP/IP packets, virtually all engineering units, with U Built-In Excitation or serve web pages over a LAN a selectable decimal point that is Firmware Selectable at or the internet. Optional serial perfect for use with pressure, flow, 5V, 10V, 12V, and 24V communications are also available or other process input. configurable as RS232 or RS485, U Full Scale P ositive and Two alarms can be configured with straightforward ASCII Negative Readings for above, below, hi/lo, and band commands or MODBUS . All three U NEMA 4 (IP65) Front triggering using either absolute types of communications interfaces 1 1 Bezel ( 32 and 16 DIN) or deviation alarm trigger points. (USB, ethernet, and serial) can be 1 In addition, high-high/low-low installed and active simultaneously. or NEMA 1 ( 8 DIN) 1 Protocols: OMEgA ASCII, MODBUS Specifications DP32Pt Series: ASCII/RTU INPUTS 25.4 H x 48 W x 127 mm D ISOLATION Input Types: Thermocouple, (1.0 x 1.89 x 5 ) RTD, thermistor, analog voltage, analog Approvals: UL, cUL, CE Panel Cutout: current, strain DP8Pt Series: 45 H x 92 mm W Power to Input/Output: 2300 Vac per 1 Current Input: 4 to 20 mA, 0 to (1.772 x 3.622 ), 8 DIN 1 min test 1500 Vac per 1 min test 24 mA scalable DP16Pt Series: 45 mm (1.772 ) (low voltage/power option) 1 square, 16 DIN Voltage Input: -100 to 100 mV, Power to Relays/SSR Outputs: DP32Pt Series: 22.5 H x 45 mm W -1 to 1 V, -10 to 10 Vdc scalable 2300 Vac per 1 min test 1 (0.886 x 1.772 ), 32 DIN Thermocouple Input (ITS 90): Relays/SSR to Relay/SSR Outputs: Environmental Conditions: K, J, T, E, R, S, B, C, N 2300 Vac per 1 min test 0 to 50C (32 to 122F), 90% RH RTD Input (ITS 90): 100/500/1000 RS232/RS485 to Inputs/Outputs: non-condensing Pt sensor, 2-, 3- or 4-wire 0.00385, 500 Vac per 1 min test External Fuse Required: 0.00392 (100 only), or 0.003916 GENERAL Time-Delay, UL 248-14 Listed: (100 only) curves 100 mA/250 V 400 mA/250 V Display: 4-digit, 9 segment LED Thermistor Input: 2252 , 5K , 10K (low voltage option) DP32Pt, DP16Pt: Strain Input: 50 mV, 100 mV Time-Lag, IEC 127-3 Recognized: 10.2 mm (0.40 ) Configuration: Differential 100 mA/250 V 400 mA/250 V DP8Pt/DP8EPt: 21 mm (0.83 ) Polarity: Bipolar (low voltage option) Dimensions: Resolution: 0.1 temperature Line Voltage/Power: 90 to 240 Vac DP8Pt Series: 10 V process 10%, 50 to 400 Hz*, 110 to 375 Vdc, 48 H x 96 W x 127 mm D equivalent voltage (1.89 x 3.78 x 5 ) Input Impedances: *No CE compliance above 60 Hz. DP16Pt Series: Process/Strain: 10M for Max Power Consumption: 48 H x 48 W x 127 mm D 100 mV, 1M for other voltage ranges 4 W power (1.89 x 1.89 x 5 ) Process Current: 5 Thermocouple: 10K max Temperature Stability: Ranges and Accuracies for Supported Inputs RTD: 0.04C/C Input Type Description Range Accuracy Thermocouple 25C (77F): 0.05C/C (cold junction compensation) Process/Strain Process Voltage 50 mV, 100 mV, 1, 10 Vdc 0.03% FS Process/Strain: 50 ppm/C A/D Conversion: 24-bit sigma delta Process Process Current Scalable within 0 to 24 mA 0.03% FS Reading Rate: 20 samples per second Iron-Constantan -210 to 1200C (-346 to 2192F) 0.4C (0.7F) Digital Filter: Programmable from 0.05 seconds (filter = 1) to CHROMEgA - -270 to -160C (-454 to -256F) 1.0C (1.8F) 6.4 seconds (filter = 128) ALOMEgA -160 to 1372C (-256 to 2502F) 0.4C (0.7F) CMRR: 120 dB Copper- -270 to -190C (-454 to -310F) 1.0C (1.8F) Excitation: Firmware selectable Constantan -190 to 400C (-310 to 752F) 0.4C (0.7F) (no jumpers to set) to 5, 10, 12, and 24 Vdc 25 mA CHROMEgA - -270 to -220C (-454 to -364F) 1.0C (1.8F) Setpoint Adjustment: 4 digit (-9999 to Constantan -220 to 1000C (-364 to 1832F) 0.4C (0.7F) +9999 counts), 6 digit (-99999 to +999999 counts) Pt/13%Rh-Pt -50 to 40C (-58 to 104F) 1.0C (1.8F) Warm-Up to Rated Accuracy: 30 mins 40 to 1788C (104 to 3250F) 0.5C (0.9F) ALARM OUTPUTS (OPTIONAL) Pt/10%Rh-Pt -50 to 100C (-58 to 212F) 1.0C (1.8F) SPDT Relay: Single pole, double throw 100 to 1768C (212 to 3214F) 0.5C (0.9F) mechanical relay, 250 Vac or 30 Vdc at 30%Rh-Pt/6%Rh-Pt 100 to 640C (212 to 1184F) 1.0C (1.8F) 3 A (resistive load) 640 to 1820C (1184 to 3308F) 0.5C (0.9F) Isolated Analog: Isolated, user programmable 0 to 5, 0 to 10, 4 to 20 mA, 5%Re-W/26%Re-W 0 to 2320C (32 to 4208F) 0.4C (0.7F) or 0 to 24 signal Nicrosil-Nisil -250 to -100C (-418 to -148F) 1.0C (1.8F) COMMUNICATIONS (USB -100 to 1300C (-148 to 2372F) 0.4C (0.7F) STANDARD, OPTIONAL SERIAL AND ETHERNET) Pt, 0.00385, 100 , -200 to 850C (-328 to 1562F) 0.3C (0.7F) Connection: 500 , 1000 USB: Female micro-USB Ethernet: Standard RJ45 Pt, 0.003916, 100 -200 to 660C (-328 to 1220F) 0.3C (0.7F) Serial: Screw terminals Pt, 0.00392, 100 -200 to 660C (-328 to 1220F) 0.3C (0.7F) USB: USB 2.0 host or device Ethernet Standards Compliance: IEEE Thermistor 2252 -40 to 120C (-40 to 248F) 0.2C (0.35F) 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPgET Thermistor 5K -30 to 140C (-22 to 284F) 0.2C (0.35F) Serial: Software selectable RS232 Thermistor 10K -20 to 150C (-4 to 302F) 0.2C (0.35F) or RS485 programmable 1200 to 115.2 K baud 2