1 8 DIN HIgH-PerformaNce meters alarm/coNtrol caPabIlItIes straIN gage, Process Voltage aND curreNt, temPerature DP41 series DP41-S strain meter shown actual size. All Units Feature: Standard features include 6-digit Voltage/Current Inputs: U 5-Year Warranty display 5 front-panel pushbutton U 0.005% Rdg Accuracy keys 4 open-collector outputs and U 6-Digit Display U 10 User-Selectable alarm/control, BCD, and analog U Min/Max Storage Voltage or 4 to 20/ outputs. Configurable analog output U 4 Isolated Open-Collector ranges are 0 to 20 mA, 4 to 20 mA, 0 to 20 mA Input Ranges Outputs 0 to 5 Vdc, and 0 to 10 Vdc. U Fully Scalable Display Up U NEMA 4 (IP65) Front Panel On-board excitation allows these to 500,000 Counts meters to power virtually any sensor U 12 Readings per Second U 1.5 to 11 Vdc or 24 Vdc or transmitter, and 4 setpoints give U Alarm/Control Capabilities Sensor Excitation the user numerous control/alarm U Smart Filtering Detects possibilities. Setpoint configurations U Adjustable Decimal Point include active above or below the Difference Between a latching or non-latching and high Spike or Process Change The OMEGA DP41 Series of digital deviation, low deviation, or band panel meter/controllers has set the (Patent Applied for) deviation. world standard for accuracy and U Peak and Valley Detection quality in industrial instrumentation. With the RS232/485 serial U Digital Tare These meters can measure a broad communications option, the user spectrum of DC voltage and current can set the display parameters U Easy Front-Panel ranges as well as inputs from and read the current, max, and Programming 9 thermocouple types and from min values remotely. The DP40-R U Optional BCD Output most RTDs, pressure transducers, board option provides dual 7 A U Optional Analog Output load cells, strain gages, and mechanical relays, activated by the potentiometers. Models include the selected setpoint. U Optional RS232/RS485 DP41-W, a legal-for-trade, NTEP- Communications certified strain meter with enhanced U Optional Mechanical Relays features, and the DP41-U, which covers all the input types. Thermocouple Input: U 0.01 Resolution The DP41 displays feature 14-segment LED characters, which greatly improves U 0.2C Accuracy alphanumeric representations. The 7-segment LED characters found on most U 9 Thermocouple Types instruments are adequate for presenting U C/F/K Units numbers, but not letters. Words are U Uses Complete NIST easier to read with Calibration Tables the 14-segment 14-segment display 14-segment LED RTD Input: LED characters on the DP41, which, U 0.01 Resolution in turn, simplifies U 0.2C Accuracy operating and Red LED display standard. Also 7-segment display U 2-, 3-, or 4-Wire programming. 7-segment LED available with green LED at no charge. U 385 and 392 Pt Curves D-29INSTRUMENTATION HIgH-PerformaNce meters Offset Adjustment: 0 to 999,999 or Sensor Break Protection: Up-scale or SPECIFICATIONS 0 to -99,999, programmable down-scale, programmable Accuracy: 0.005% rdg Thermocouple Input Types: Sensor Excitation: 10 V at 30 mA Span Temperature Coefficient: 20 ppm J, K, T, E, R, S, B, N, J DIN 24V at 25 mA Step Response: 1 s to 99.9% RTD Input: Any 6 to 6 k NIST or Warm-Up to Rated Accuracy: 50 minutes DIN platinum and any linear RTD Operating Environment: 0 to 50C RTD Connection: 2-, 3- or 4-wire (32 to 122F) 95% RH, non-condensing Storage Temperature: -40 to 85C (-40 to 185F) Power: 115 or 230 Vac, 49 to 400 Hz 10 to 32 Vdc Power Consumption: 6 W nom., 10 W max The DP41 thermocouple meter offers very high accuracy ensured by an Normal-Mode Rejection: 60 dB advanced (patent applied for) thermocouple linearizing system. Accuracy Common-Mode Rejection: 120 dB for most thermocouple types is 0.2C (3.6F). The meter is front-panel Common-Mode Voltage: programmable for any of 9 thermocouple types. The DP41 RTD input meter 1500 Vp per HV test is programmable for any 6 to 6000 DIN or NIST platinum RTD. It provides Resolution: 15-bit a precision ultra-low constant current excitation to minimize self-heating Conversion: Dual-slope technique errors and maximize stability. Reading Rate: 3/s or 13/s, 60 Hz 3/s or 12/s, 50 Hz INPUT TYPE RANgE, C RANgE, F ACCURACY Display: Red or green 6-digit, 14-segment, Iron-constantan -210 to 760 -346 to 1400 0.2C/0.3F 13.7 mm (0.54 ) high 4 alarm indicators CHROMEGA -ALOMEGA -270 to 1372 -454 to 2500 0.2C/0.3F Dimensions: 48 H x 96 W x 165 mm D (1.89 x 3.78 x 6.5 ) Copper-constantan -270 to 400 -454 to 752 0.2C/0.3F Panel Cutout: 45 H x 92 mm W 1 CHROMEGA -constantan -270 to 1000 -454 to 1832 0.2C/0.3F (1.772 x 3.622 ) 8 DIN Weight: 574 g (1.27 lb) Pt/Rh -50 to 1768 -58 to 3214 0.2C/0.3F / Setpoint Outputs: 4 isolated open Pt/30% Rh-Pt/6 Rh 100 to 1820 212 to 3300 0.3C/0.5F collector rated 150 mA at 1V sink, 30V open OMEGALLOY -270 to 1300 -454 to 2372 0.2C/0.3F BCD Output: Isolated, tri-state, Iron-constantan -200 to 900 -328 to 1652 0.6C/1.0F TTL/CMOS compatible external All curves -200 to 850 -328 to 1562 0.2C/0.3F 5V supply required for isolated internal 5V supply for non-isolated Dual Relays: Form C, 7 A 30 Vdc D or 230 Vac INPUT TYPE RANgE, C RANgE, F RANgE, K ACCURACY 4-Relay Option: Dual 7 A relays RTD 1 10 copper -200 to 200 -328 to 392 73.2 to 473.2 1.0C/2.0F/1.0 K and dual 1 A relays RTD 2 100 Pt 0.00385 200 to 900 -328 to 1652 73.2 to 1173.2 0.2C/0.3F/0.2 K Analog Output: 0 to 5V/1 to 5V/ 0 to 10V/0 to 20 mA/4 to 20 mA, user RTD 3 100 Pt 0.00392 -200 to 850 -328 to 1562 73.2 to 1123.2 0.2C/0.3F/0.2 K selectable 354 Vp isolation 15-bit resolution 0.1% accuracy 50 ms step response Thermocouple and RTD RS232 Communications: probes sold separately. Visit 300/600/1200/2400/4800/9600/ omega.com/temperature, 19.2K baud RJ11 4-wire connection for the complete selection programmable to transmit current of temperature products display, alarm status, min/max, actual available from OMEgA measured input value and status RS485 Communications: 300/600/1200/2400/4800/9600/ 19.2K baud RJ12 6-wire connection addressable from 0 to 199 Voltage Input Ranges: 0 to 100 mV, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 0 to 100V, 50 mV, 500 mV, 5V, 50V Current Input Ranges: 0 to 20 mA, 4 to 20 mA Input Configuration: Single-ended Polarity: Unipolar/bipolar, programmable Span Adjustment: 0.00001 to 500,000, DP41-T and DP41-RTD shown smaller than actual size. programmable D-30