Wheatstone Bridge IN-UVI, shown smaller In-Line Signal Conditioner than actual size, with one M12 accessory connector. Supply Voltage: 22 to 32 Vdc Input Current: 200 mA Start Up (90 mA max) Current Outputs: 4-20 mA, 12 mA zero 8 mA Voltage Outputs: 0-5, 0-10, 5, 10 Vdc M12 connector accessory, IN-UVI Series shown smaller than actual size signals from 0.5 mV/V to 4 mV/V, Application Examples: wide zero adjustment range and U Monitor Compression an isolated shunt calibration relay U Wide Range of Field Forces of an Automated for quick field setup. All output Selectable Inputs and Clamping Machine that options and excitation voltages Outputs are field selectable. Modifies 44 Assembly U Input/Output Isolation Pieces at a Time by Specifications U Low Thermal Drift Automated Drills Supply Voltage: 22 to 32 Vdc isolated from output U IP65 Protected U Monitor Forces Needed Isolation Input to Output: 500 Vdc to Raise the Roof of U Rugged Stainless Steel Capacitance: 0.022 F an Aviation Hanger for Enclosure Resistance: 100 M Larger Airships to Fit Input Current: 90 mA maximum U Ideal for Use with (must be capable of supplying Inside Miniature Transducers or 200 mA) When Space is Limited Voltage Output: 5 volts, 10 volts at The OMEGA IN-UVI in-line signal 2 mA maximum U Improved Signal to conditioner is housed in a rugged Output Resistance: 60 stainless steel enclosure, which is Noise Ratio connected between the transducer Noise: 10 mV peak to peak 3 mV/V U Signals Can Be Sent voltage mode (10 Vdc) 20 uA peak to and a readout instrument. The Over Much Longer peak current mode signal conditioner supplies a highly Distances than Millivolt Short Circuit Protection: Yes +output regulated bridge excitation voltage to -output for the transducer and converts the Signals Current Output: 4 to 20 mA, 12 mA millivolt signal of the transducer to zero 8 mA outputs field 0 to 5, 0 to 10, 5, 10 Vdc or Typical Applications that programmable 4 to 20, 12 8 mA. Require an In-Line Signal Maximum Load Resistance: 700 Conditioner: The IN-UVI features include two at 20 mA selectable excitation voltages, Operating Temperature: -20 to 60C U When a Transducer is programmable gain amplifier for (0 to 140F) Located in a Hostile Environment* or Some Dimensions: mm (in) Distance From the Display 34.8 134.8 (5.306) (1.37) U Potentiometer 114.3 (4.50) 6.35 Adjustments (Which are (0.250) Located in the Signal Conditioner) are More Conveniently Located 63.5 52.3 and More Accessible (2.501) (2.06) than the Transducer Itself * If the environment at the sensing site is 31.2 (1.23) subject to high temperatures, humidity, or corrosive conditions, it may be necessary 5.4 (0.213) to place the in-line signal conditioner away from the transducer. 1Response Time: 200 uS (0 to 63%) Temperature Effects: Dimensions: 134.8 L x 34.8 H x 31.2 mm D Excitation Voltage: 5 or 10 Vdc field Zero: 0.001%/F (Auto zero front end) (5.3 x 1.37 x 1.23) programmable Span: 0.0025%/F Excitation Max Current: 30 mA Linearity: 0.01% Transducer Requirements: 10 Vdc Adjustment Range: Bridge Excitation: 5 Vdc or 10 Vdc Sensor Input Range: 0.5 mV/V to 4 Zero: 30% Bridge Sensitivity: 1 to 8 mV/V mV/V in 0.5 steps Span: 20% fine 40% coarse 5 Vdc EXC, 0.5 to 4 mV/V for Shunt Cal: Yes remotely activated 10 Vdc EXC Adjustment Location: Behind Environmental Protection: IP65 connector endcaps Bridge Resistance: 350 to 5000 * * Time constant 0 to 63% (200 S for a Long Term Zero Drift: 0.1% of FS/year EMC Effect: <0.15% of FS per 350 bridges/1.2 mS for a 5000 bridge) EN61326-1 (industrial) NOTE: There are TWO different connectors offered as ACCESSORIES: 1. Model No: M12.8-S-F-FM Description: 8-Pin M12 Connector with Cable Gland, Input/Output Connection 2. Model No: M12.5-S-F-FM Description: 5-Pin M12 Connector with Cable Gland, Sensor Connection 5 4 3 6 4 7 3 1 2 1 2 5 CENTER PIN STAMFORD, CT 04907-0047 USA 8 CENTER PIN 5 CENTER PIN 8 CENTER PIN MODEL: IN-UVI INLINE AMPLIFIER SUPPLY RANGE: 22 TO 32 VDC 200 mA SERIAL NO: XXXXXXX PIN 1 = + SUPPLY 8 PIN M12 5 SENSOR WIRING 4 3 PIN 2 = RETURN 6 4 8 PIN M12 PIN 1 = + EXC M12 CONNECTOR PIN 3 = + OUTPUT VI PIN 2 = - EXC PIN 1 = + SUPPLY M12 CONNECTOR 7 3 PIN 1 = +SUPPLY PIN 4 = - OUTPUT 2 1 PIN 3 = + SIG PIN 1 = + EXCITATION PIN 5 = SHUNT CAL 1 2 PIN 4 = - SIG PIN 1 = +EXCITATION CS PIN 2 = SUPPLPIN 2 = SUPPLY RETURNY RETURN FS Z 5 CENTER PIN PIN 6, PIN 7 = NC 8 CENTER PIN PIN 5 = SHIELD PIN 2 = EXCITATION PIN 8 = CASE PIN 3 = +OUTPUT PIN 2 = -EXCITATION PIN 3 = + OUTPUT PIN 3 = +INPUT PIN 4 = -OUTPUT PIN 3 = + INPUT PIN 4 = OUTPUT PIN 4 = -INPUT PIN 5 = SHUNT CAL 1 PIN 4 = INPUT PIN 5 = SHIELD PIN 5 = SHUNT CAL1PIN 6 = N/C PIN 5 = SHIELD SHUNT CAL RESISTOR (INTERNAL CONNECTOR) PIN 7 = N/C PIN 6 = N/C PIN 8 = SHIELD SHUNT CAL RESISTOR PIN 7 = N/C (INTERNAL CONNECTOR) PIN 8 = CASE/SHIELD + POPOWER SUPPLWER SUPPLY Y STANDARD LOAD CELL OR 28 VDC 200 mA STANDARD LOAD CELL OR PRESSURE SENSOR 28 VDC 200 mA PRESSURE SENSOR MINIMUM - MINIMUM + DATA SYSTEM DATA SYSTEM OR DISPLAY OR DISPLAY - REMOTE SHUNT CAL SWREMOTE SHUNT CAL SW CLOSE SWITCH TO ENABLE CLOSE SWITCH TO ENABLE To Order Model No. Description IN-UVI Wheatstone bridge in-line signal conditioner Accessories Model No. Description M12.5-S-F-FM 5-pin M12 connector with cable gland, sensor connection M12.8-S-F-FM 8-pin M12 connector with cable gland, input/output connection 2