MINIATURE HIGH-CAPACITY TOP HAT LOAD CELL sTANDARD AND METRIC MODELs Compression 0-250 lb to 0-100,000 lb LCM307-5KN, shown 0-1 to 0-500 kN LCM307-5KN, actual size. shown larger 1 Newton = 0.2248 lb than actual size. 1 daNewton = 10 Newtons 1 lb = 454 g 1 t = 1000 kg = 2204 lb LC307/LCM307 series D 2 Spherical Radius (SR) Standard COLOR CODE RED = +INPUT BLACK = INPUT GREEN = OUTPUT WHITE = +OUTPUT E H Small in size but not in performance, A Supplied with 1.5 m Cable Series LC307/LCM307 top hat load D with Compensation Board 3 cells are designed for applications with minimum space and high-capacity D 1 loads up to 100,000 lb. Rugged all stainless steel construction and high-performance strain gages ensure superior linearity and stability. STANDARD Dimensions: mm (inch) Temperature compensation is CAPACITy (lb) D1 D2 D3 E H done by a miniature circuit board in the load cells cable. These cells 250 12.7 (0.50) 6.9 (0.27) 10.16 (0.40) 9.7 (0.38) 8.13 (0.320) are designed to be mounted on a 500 12.7 (0.50) 7.1 (0.28) 10.16 (0.40) 9.7 (0.38) 8.13 (0.320) smooth, flat surface. 1000 12.7 (0.50) 7.9 (0.31) 10.16 (0.40) 9.7 (0.38) 8.13 (0.320) 2000 12.7 (0.50) 10 (0.41) 10.16 (0.40) 9.7 (0.38) 8.13 (0.320) 3000 12.7 (0.50) 11 (0.45) 10.16 (0.40) 9.7 (0.38) 8.13 (0.320) SPECIFICATIONS 5000 16.0 (0.63) 13.5 (0.53) 10.16 (0.40) 15 (0.60) 13.54 (0.533) Excitation: 5 Vdc 7500 22.2 (0.88) 17 (0.67) 10.16 (0.40) 16 (0.63) 13.97 (0.55) Output: 1.5 mV/V nominal 10,000 22.2 (0.88) 19.3 (0.76) 10.16 (0.40) 16 (0.63) 13.97 (0.55) Accuracy: 0.75% FS BFSL (includes 50,000 44.5 (1.75) 31.8 (1.25) 10.16 (0.40) 35 (1.38) 31.34 (1.234) linearity, hysteresis and repeatability) Zero Balance: 2% FSO 100,000 50.8 (2.00) 38.1 (1.50) 10.16 (0.40) 41 (1.63) 37.33 (1.470) Operating Temp Range: METRIC Dimensions: mm (inch) -54 to 121C (-65 to 250F) Compensated Temp Range: CAPACITy (kN) D1 D2 D3 E H A 16 to 71C (60 to 160F) 1 to 10 12.7 10.16 7.62 9.53 8.13 0.254 Thermal Effects: (0.500) (0.400) (0.300) (0.375) (0.320) (0.010) Span: 0.018% rdg/C Zero: 0.018% FSO/C 20 16.00 13.46 13.54 15.24 13.54 0.381 (0.630) (0.530) (0.533) (0.600) (0.533) (0.015) Safe Overload: 150% of capacity Ultimate Overload: 300% of capacity 50 22.22 19.30 13.97 16.00 13.97 0.381 Bridge Resistance: 350 minimum (0.875) (0.760) (0.550) (0.630) (0.550) (0.015) Full Scale Deflection: 0.001 to 0.003 200 44.45 31.75 25.40 35.05 31.34 0.381 Electrical Connection: (1.750) (1.250) (1.000) (1.380) (1.234) (0.015) 1.5 m (5 ) 4-conductor cable with compensation board 500 50.8 38.10 30.48 41.40 37.33 0.762 (0.030) (2.000) (1.500) (1.200) (1.630) (1.470) Protection Class: IP54 F-31LOAD CELLS STANDARD MODELS To Order CAPACITy lb kN MODEL NO. COMPATIBLE METERS** 250 1.11 LC307-250 DPiS, DP41-S, DP25B-S 500 2.22 LC307-500 DPiS, DP41-S, DP25B-S 1000 4.45 LC307-1K DPiS, DP41-S, DP25B-S LCM307-500, shown larger 2000 8.90 LC307-2K DPiS, DP41-S, DP25B-S than actual size. 3000 13.3 LC307-3K DPiS, DP41-S, DP25B-S 5000 22.2 LC307-5K DPiS, DP41-S, DP25B-S 7500 33.4 LC307-7.5K DPiS, DP41-S, DP25B-S 10,000 44.5 LC307-10K DPiS, DP41-S, DP25B-S 50,000 222 LC307-50K DPiS, DP41-S, DP25B-S* 100,000 445 LC307-100K DPiS, DP41-S, DP25B-S* METRIC MODELS CAPACITy kN lb MODEL NO. COMPATIBLE METERS Comes complete with 5-point 1 225 LCM307-1KN DPiS, DP41-S, DP25B-S NIST-traceable calibration and 59 k shunt data. 4-digit meter. 2 450 LCM307-2KN DPiS, DP41-S, DP25B-S * Ordering Examples: LC307-5K, 5 1124 LCM307-5KN DPiS, DP41-S, DP25B-S 5000 lb capacity top hat load cell. 10 2248 LCM307-10KN DPiS, DP41-S, DP25B-S LC307-500, 500 lb capacity top hat load cell. 20 4496 LCM307-20KN DPiS, DP41-S, DP25B-S LCM307-50KN, 50 kN capacity top hat 50 11,240 LCM307-50KN DPiS, DP41-S, DP25B-S load cell. LCM307-10KN, 10 kN capacity top hat 200 44,960 LCM307-200KN DPiS, DP41-S, DP25B-S load cell. 500 112,400 LCM307-500KN DPiS, DP41-S, DP25B-S MAkE IT wIRELEss ADD wIRELEss CAPAbILITY TO YOUR PROCEss MEAsUREMENT sYsTEM Wireless Connections From your Sensor to your Instrumentation: U Thermocouple, RTD, Infrared Temperature, Humidity, pH, as well as WRS232-USB wireless transmitter, Process Voltage/Current shown close to actual size. U Easy to Install and Use Wireless Communications U Capable of Distances From your Instrument to up to 120 m (400 ) a PC: U Convert the RS232 Signal on your Meter, UWTC-1 Controller or PLC Both models U Works with any PC z shown smaller I with a USB Port than actual size. U Easy to Install with R F Seamless Operation UWTC-REC2, U Capable of Distances available with up to 120 m (400 ) 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc and Type K Laptop not included. thermocouple output. F-32