Industrial Non-Contact Infrared Thermometer/Transmitter with Local Display and Analog Output Accuracy 1% of Reading Models with Temperature Ranges Measuring Up to OS550 sensor head 1370C (2500F) (included) shown With optional Current, Voltage, mounting bracket and mounting nut. or Millivolt Output Laser Sight Optional C/F Keypad Selectable OS550, Local Backlit LCD shown smaller Display Standard than actual size. Dual Display Indicates Current plus Min, Max, Average, or Differential Available OS550-MN Temperatures on Most Models Accessories mounting nut. Visual and Audible High OS550-MF Alarm Low Alarm mounting (OS552, OS553, OS554) frame. Emissivity Adjustable from 0.1 to 1.00 in 0.01 Steps via the Programmable Keypad OS550-MB OS550-WC mounting Fast 250 msec Response Time air/water cooling bracket. jacket. Complete NEMA 4 OS550-AP (IP66) System air purge collar. RS232 Communication We make running changes when technical advances allow. Check at time Available of ordering for additional features. Specifications OMEGAs OS550 Series industrial, Accuracy: 1% of reading 25C high-performance, economical ambient or 1.7C (3F), whichever Connection: 4.5 m (15 ), head and thermometer/transmitter offers a is greater power cable included wide choice of temperature ranges, Repeatability: 1% rdg 1 digit Dimensions: optical patterns, or fields of view Spectral Response: 8 to 14 microns Sensing Head: 10.9 x 4.1 cm and 3 outputs (1 mV/degree, 1 Emissivity Range: 0.10 to 1.00 (4.30 x 1.63 ), 1 2 to 20 thread 4 to 20 mA, and 0 to 5 Vdc) to Field of View (FOV): See diagrams Electronics: 13.3 x 9.1 cm feed directly into panel meters, Display: Backlit LCD (5.25 x 3.62 ) recorders, temperature/process Transmitter Outputs: 1 mV/degree, 0 Weight: controllers, data loggers, data to 5 Vdc or 4 to 20 mA Sensing Head: 0.45 kg (12 oz) acquisition systems, or other Power: 7 to 24 Vdc 80 mA Electronics Mounted in NEMA 4 process instrumentation. Environmental Ratings: NEMA 4 (IP65) Enclosure: 1.2 kg (43.2 oz) (IP65) water-tight and dust-tight for Since the OS550 Series infrared SM sensing head and electronics enclosure OMEGACARE extended warranty program thermometers do not use chopper Ambient Operating Range: is available for models shown on this page. motors or vibrator mechanisms, Ask your sales representative for full details Sensing head 0 to 50C (32 to 122F) they can be mounted in any position SM when placing an order. OMEGACARE with OS550-WC 0 to 85C and in hostile environments without covers parts, labor, and equivalent loaners. (32 to 185F) suffering any loss in performance. Response Time: 250 msec 0 to 63.2% LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH This rugged design coupled with Alarms: Visual and audible OPTICAL INSTRUMENTS. CLASS 2 CAUTION LASER PRODUCT. relatively small dimensions makes RS232: Standard on OS552, OS553 and AVOID EXPOSURE. LASER RADIATION IS EMITTED LASER RADIATION - DO NOT STARE INTO BEAM FROM THIS APERTURE these sensors ideally suited for a OS554 models one-way communication MAX. OUTPUT 1mW, WAVELENGTH 630-670 nm, CLASS II (2) LASER PRODUCT. COMPLIES WITH FDA 21CFR 1040.10 wide variety of applications. PC compatible software included J-81 OS550 Series Optical Field of View Diagrams MOST POPULAR MODELS HIGHLIGHTED To Order Complete NEMA 4 (IP65) System (Specify Model Number) J Model No. Price Output Temperature Range RS232 Free PC Software OS551-MV-(*) 495 1 mV/deg -18 to 400C (0 to 750F) OS551-MA-(*) 495 4 to 20 mA -18 to 400C (0 to 750F) OS551-V1-(*) 495 0 to 5 Vdc -18 to 400C (0 to 750F) OS552-MV-(*) 550 1 mV/deg -18 to 540C (0 to 1000F) Standard Standard OS552-MA-(*) 550 4 to 20 mA -18 to 540C (0 to 1000F) Standard Standard OS552-V1-(*) 550 0 to 5 Vdc -18 to 540C (0 to 1000F) Standard Standard OS553-MV-(*) 650 1 mV/deg -18 to 870C (0 to 1600F) Standard Standard OS553-MA-(*) 650 4 to 20 mA -18 to 870C (0 to 1600F) Standard Standard OS553-V1-(*) 650 0 to 5 Vdc -18 to 870C (0 to 1600F) Standard Standard OS554-MV-(*) 750 1 mV/deg -18 to 1370C (0 to 2500F) Standard Standard OS554-MA-(*) 750 4 to 20 mA -18 to 1370C (0 to 2500F) Standard Standard OS554-V1-(*) 750 0 to 5 Vdc -18 to 1370C (0 to 2500F) Standard Standard * Insert optics code from table below. Accessories Note: Sensor head cable can be extended at the factory at time of purchase to a maximum of 15 m (50 ). Add suffix -(*)FT to Model No. Price Description order number and per 0.3 m (1 ) over 5 m (15 ) to price. OS550-AP 65 Air purge collar Ordering Examples: OS552-MA-2, infrared thermometer with -18 to 540C (0 to 1000F) range, 4 to 20 mA output and spot OS550-WC 195 Air/water cooling jacket size 12.7 mm (0.5 ) at 76 mm (3 ). OS551-MA-2-35FT, OS550-MF 65 Mounting frame OS551 with current output, 0.5 at 3 FOV, 11 meter sensor head SM OS550-MB 35 Right-angle mounting bracket cable. OCW-3, OMEGACARE extends standard 2-year warranty to a total of 5 years, OS550-MN 15 Mounting nut OS550-LS 195 Sighting viewer (laser) (not shown)* Optical Table* CAL-3-IR 125 NIST calibration certification CAL-3-IR-X 175 NIST calibration for over 1000F Optical Range Code Field of View (FOV) PSR-24S 60 Regulated power supply, US plug, 90 to 264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL 1 Spot size 8.9 609 mm (0.35 24 ) PSR-24L 60 Regulated power supply, US plug, 90 to 264 Vac 2 Spot size 12.7 76 mm (0.5 3 ) input, 24 Vdc output, 400 mA, stripped leads, UL 3 Spot size 25.4 508 mm (1 20 ) PSR-24L-230 60 Regulated power supply, European plug, 230 Vac 4 Spot size 25.4 762 mm (1 30 ) input, 24 Vdc output, 400 mA, stripped leads, CE 5 Spot size 25.4 1524 mm (1 60 ) TX4-100 28.50 Power/output extension wire 30 m (100 ) 6 Spot size 3.8 152 mm (0.15 6 ) * 1 unit suitable for aligning many heads. J-82