Ultra Precise 1 m of 4-wire, 26 AWG stranded cable with stripped ends standard (see table for insulation options). Immersion RTD Sensors P-M-A-1/8-6-1/4-P-3 shown smaller than actual size. Mounting PM Series thread Probe diameter U Pt100 (100 0C 0.00385//C) Platinum P-M-A-1/4-6-0-P-3 1 1 RTDs with 10 DIN, 3 DIN, shown smaller than actual size. or Class A Accuracies U Temperature Range -100 to 400C (-148 to 752F) Depending on Cable and Accuracy Selected U 4-Wire Construction in 1 1 Probe diameter 6.3 mm 6 and 3 mm ( 4 and 8 ) (0.25 ) Diameters U A Range of Mounting P-M-1/10-1/8-6-0-P-3 shown smaller Threads and Cable than actual size. Materials are Available Probe diameter Standard Dimensions To Order PVC Insulated PFA Insulated Fiberglass Insulated Sensor Mounting Model Number Model Number Model Number Accuracy Diameter Thread 6 Probe Length 6 Probe Length 6 Probe Length 1 8 None P-M-1/10-1/8-6-0-P-3 P-M-1/10-1/8-6-0-T-3 P-M-1/10-1/8-6-0-G-3 1 8 1 8 NPT P-M-1/10-1/8-6-1/8-P-3 P-M-1/10-1/8-6-1/8-T-3 P-M-1/10-1/8-6-1/8-G-3 1 10 DIN 1 1 10 DIN 4 None P-M-1/10-1/4-6-0-P-3 P-M-1/10-1/4-6-0-T-3 P-M-1/10-1/4-6-0-G-3 1 4 1 8 NPT P-M-1/10-1/4-6-1/8-P-3 P-M-1/10-1/4-6-1/8-T-3 P-M-1/10-1/4-6-1/8-G-3 1 8 None P-M-1/3-1/8-6-0-P-3 P-M-1/3-1/8-6-0-T-3 P-M-1/3-1/8-6-0-G-3 1 8 1 8 NPT P-M-1/3-1/8-6-1/8-P-3 P-M-1/3-1/8-6-1/8-T-3 P-M-1/3-1/8-6-1/8-G-3 1 3 DIN 1 1 3 DIN 4 None P-M-1/3-1/4-6-0-P-3 P-M-1/3-1/4-6-0-T-3 P-M-1/3-1/4-6-0-G-3 1 4 1 8 NPT P-M-1/3-1/4-6-1/8-P-3 P-M-1/3-1/4-6-1/8-T-3 P-M-1/3-1/4-6-1/8-G-3 1 8 None P-M-A-1/8-6-0-P-3 P-M-A-1/8-6-0-T-3 P-M-A-1/8-6-0-G-3 1 8 1 8 NPT P-M-A-1/8-6-1/8-P-3 P-M-A-1/8-6-1/8-T-3 P-M-A-1/8-6-1/8-G-3 Class A 1 Class A 4 None P-M-A-1/4-6-0-P-3 P-M-A-1/4-6-0-T-3 P-M-A-1/4-6-0-G-3 1 4 1 8 NPT P-M-A-1/4-6-1/8-P-3 P-M-A-1/4-6-1/8-T-3 P-M-A-1/4-6-1/8-G-3 For longer sheath length, change -6 in model to desired length in inches for additional cost when longer than 8 . For Silicone Rubber insulated cable, change -P, -T or -G to -S in the model number and use PFA pricing. For longer cable lengths, change -3 to desired length in feet for additional cost for PVC, for PFA or Silicone Rubber and for fiberglass. For shielding on PVC, PFA or Fiberglass insulated 1 3 1 cables, change P, T or G to PS, TS or GS for additional cost. Mounting threads also available in NPT, NPT and NPT at 4 8 2 1 the same price. diameter sensors without threaded fittings and with P, PS, TS, GS and S cables include a transition fitting at the 8 end of the sheath. 1 1 1 Ordering Examples: P-M-1/10-1/8-6-1/4-P-3, immersion sensor with diameter sheath 6 long with NPT mounting thread, 10 DIN 8 4 accuracy, 4-Wire PVC cable 3 long with stripped leads. 1 1 P-M-1/10-1/4-6-0-P-3, immerson sensor with diameter sheath 6 long with no mounting thread, DIN accuracy, 4-Wire PVC cable 3 long 4 10 with stripped leads. C-83 Probe Length (2 minimum) Probe Length (2 minimum) Probe Length (2 minimum) Interchangeability in C 1 1 C Temp C Class A 3 DIN 10 DIN -100 0.35 -50 0.25 0.18 0 0.15 0.10 0.03 100 0.35 0.27 0.08 200 0.55 0.43 250 0.65 0.52 300 0.75 350 0.85 400 0.95 450 1.05 Cable Options Temperature Range PVC Insulated -29 to 100C (-20 to 212F) PFA Insulation -100 to 250C (-148 to 482F) Fiberglass Insulation -73 to 400C (-99 to 753F) Silicone Insulated -50 to 200C (-58 to 392F) Photo by Craig Terry, courtesy of Chemical Engineering Program at Rowan University Omegas Ultra-Precise RTD sensors are used in a wide variety of applications where accuracy and precise temperature measurement means the difference between failure and success. Why not join the growing list of customers utilizing the best the market has to offer. Metric Dimensions To Order PVC Insulated PFA Insulated Fiberglass Insulated Sensor Mounting Model Number Model Number Model Number Accuracy Diameter Thread 150 mm Probe Length 150 mm Probe Length 150 mm Probe Length None P-M-1/10-M30-150-0-P-1 P-M-1/10-M30-150-0-T-1 P-M-1/10-M30-150-0-G-1 3 mm M6x1 P-M-1/10-M30-150-M6-P-1 P-M-1/10-M30-150-M6-T-1 P-M-1/10-M30-150-M6-G-1 1 10 DIN None P-M-1/10-M60-150-0-P-1 P-M-1/10-M60-150-0-T-1 P-M-1/10-M60-150-0-G-1 6 mm M8x1 P-M-1/10-M60-150-M8-P-1 P-M-1/10-M60-150- M8-T-1 P-M-1/10-M60-150-M8-G-1 None P-M-1/3-M30-150-0-P-1 P-M-1/3-M30-150-0-T-1 P-M-1/3-M30-150-0-G-1 3 mm M6x1 P-M-1/3-M30-150-M6-P-1 P-M-1/3-M30-150-M6-T-1 P-M-1/3-M30-150-M6-G-1 1 3 DIN None P-M-1/3-M60-150-0-P-1 P-M-1/3-M60-150-0-T-1 P-M-1/3-M60-150-0-G-1 6 mm M8x1 P-M-1/3-M60-150-M8-P-1 P-M-1/3-M60-150-M8-T-1 P-M-1/3-M60-150-M8-G-1 None P-M-A-M30-150-0-P-1 P-M-A-M30-150-0-T-1 P-M-A-M30-150-0-G-1 3 mm M6x1 P-M-A-M30-150-M6-P-1 P-M-A-M30-150-M6-T-1 P-M-A-M30-150-M6-G-1 Class A 6 mm None P-M-A-M60-150-0-P-1 P-M-A-M60-150-0-T-1 P-M-A-M60-150-0-G-1 M8x1 P-M-A-M60-150-M8-P-1 P-M-A-M60-150-M8-T-1 P-M-A-M60-150-M8-G-1 For longer sheath length, change -150 in model number to desired length in millimeters for additional cost to the price when longer than 200 mm. For Silicone Rubber insulated cable, change -P, -T or -G to -S in the model number and use PFA pricing. For longer cable lengths, change -1 to desired length in meters for additional cost per meter for PVC, for PFA or Silicone Rubber and for fiberglass. For shielding on PVC, PFA or Fiberglass insulated cables, change P, T or G to PS, TS or GS for additional cost per meter to the price. Mounting threads also available in M8x1 and M10x1 at the same price (Note: M6 threads not available on 6 mm Dia probes). 3 mm diameter sensors without threaded fittings and with P, PS, TS, GS and S cables include a transition fitting at the end of the sheath. Ordering Examples: P-M-1/10-M30-100-M6-P-1, immersion sensor with 3 mm diameter sheath 120 mm long with M6x1 mounting thread, 1 DIN accuracy, 4-Wire PVC cable 1 meter long with stripped leads. 10 1 P-M-1/10-M60-125-0-P-1, immerson sensor with 6 mm diameter sheath 125 mm long with no mounting thread, DIN accuracy, 4-Wire PVC 10 cable 1 meter long with stripped leads. C-84