MILLIVOLT OUTPUT PRESSURE TRANSDUCERS HIGH ACCURACY TRANSDUCERS mICRo-mACHINED SIlICoN wITH VACUUm PRESSURE RANGES IP67 rated Vacuum Pressure Ranges PX409-015VV mV/V, Voltage or Current outputs 0 to -15 psi vaccum range Cable style. shown actual size. PX409 Series mini DIN Standard style. Metric threads available B IP65 rated PX419-001V5V U High Accuracy 0 to -1 psi vacuum range 0.08% BSL Includes shown actual size. Linearity, Hysteresis, and Repeatability Thermal Effects Span (Over U Broad Temperature Compensated Range): Compensated Range Ranges >5 psi: 0.5% span SPECIFICATIONS -29 to 85C (-20 to 185F) Ranges 5 psi: 1.0% span Output: Long Term Stability (1-Year): U Premium Temperature Millivolt: 0 to 10 mV/V for vacuum 0.1% FS typical Performance Span: Amplified Voltage: 0 to 5 Vdc Shock: 50 g, 11 mS half sine, vertical for vacuum 0.5% Over and horizontal axis Current Loop: 4 to 20 mA Compensated Range Vibration: 5-2000-5 Hz, 30 minute Power Requirements: cycle, Curve L, Mil-Spec 810 figure U 5-Point NIST Traceable Millivolt: 5 to 10 Vdc (2 mA 10 Vdc) 514-2-2, vertical and horizontal axis Calibration Included Amplified Voltage: Response Time: <1 ms 10 to 30 Vdc 10 mA U All Stainless Steel Bandwidth: DC to 1 kHz typical Current Loop: 9 to 30 Vdc Wetted Parts Proof Pressure (positive direction): max loop res = (Vs-9) x 50 10 inH O: 10 times full scale U Fast Response Time 2 9 to 20 Vdc above 105C (229F) 1 psi: 6 times full scale CE Compliant: Meets industrial emission U Solid State Reliability 2.5 psi and Higher: 4 times full scale and immunity standard EN61326 and Stability (Negative direction 4 times or Accuracy (Combined Linearity, 1 atmosphere whichever is greater) U 400% Proof Pressure Hysteresis and Repeatability): Burst Pressure: 0.08% BSL max Minimum 10 inH O to 15 psi: 1000 psi Zero Balance: 0.5% FS typical 2 1% max (1% typical, 2% max Electrical Termination: for ranges 1 psi and below) PX409: Integral 2 m (6 ) cable OMEGAs PX409 Series high Span Setting: 0.5% FS typical 1% max PX419: mini DIN (1% typical, 2% max for ranges 1 psi and accuracy uni-directional vacuum PX429: Twist-lock below) calibrated in vertical direction range (negative gage pressure) PX459: M12 4-pins with fitting down models have all stainless Mating Connectors: Operating Temperature Range: steel wetted parts and welded PX419: CX5302 (included) -45 to 121C (-49 to 250F) construction and premium -45 to 115C (-49 to 240F) PX429: PT06F10-6S (sold separately) temperature compensation which for voltage or current outputs Environmental Protection: makes them suitable for use in Compensated Temperature: PX409: IP67 tough industrial environments. Ranges >5 psi: -29 to 85C PX419, PX429 and PX459: IP65 Vacuum models measure negative (-20 to 185F) Wetted Parts: 316 SS gage pressure with increasing Ranges 5 psi: -17 to 85C 1 Pressure Port: output for increasing negative -18 NPT male 4 (0 to 185F) pressure. Ranges are from -10 Calibration: Comes with 5-point Thermal Effects Zero ( 0 psig inH O to -15 psi with uni-directional calibration certificate 2 Over Compensated Range): outputs of 10 mV/V, 0 to 5 Vdc and Weight: 115 to 200 g (4 to 7 oz) Ranges >5 psi: 0.5% span 4 to 20 mA (ambient set at 4 mA). depending upon configuration Ranges 5 psi: 1.0% span B-18Conduit back end PXM409C 28 (1.1) HIGH ACCURACY TRANSDUCERS Twist-lock style. ITHw VACUUm PRESSURE RANGES mini DIN style. Integral cable back end PXM409 PX429-015VV 5 Product Label (0.2) PX429 TWIST LOCK PINOUT PX409-005V5V PX419-015VI PIN mV 5/10V mA Hex 22 (0.87) AF PX419 and PX459 PIN OUT PX409 and PX409C CABLE CONNECTION A + EXC + EXC + Supply -18 NPT Pressure Adaptor Twist lock back end PXM429 COLOR mV 5/10V mA PIN mV 5/10V mA B EXC Common Supply 5 22 1 + EXC + EXC + Supply Black EXC Common Supply C + SIG + Output NC (0.2) (0.88) White + SIG + Output NC 2 EXC Common Supply D SIG NC NC Vent with Green SIG NC NC 3 + SIG + Output NC porous plug E NC NC NC 81 (3.2) (gage units only) 4 SIG NC NC Red + EXC + EXC + Supply F NC NC NC All models shown smaller than actual size. mini DIN back end PXM419 5 81 (3.2) Dimensions: mm (inch) (0.2) Metric threads available 22 Vent with porous plug (0.88) Custom Models Available (gage units only) -18 NPT Pressure Adaptor Glass to medal sealed pins PXM449 5 Hex 2.5 (1.0) AF (0.2) To Order VACUUM (NEGATIVE GAGE) RANGES RANGE Integral cable back end PXM409 psi VACUUM mbar 2 m (6 ) CABLE mini DIN TWIST-LOCK M12 CONN. NEGATIVE GAGE GAGE TERMINATION TERMINATION TERMINATION TERMINATION 9 PRESSURE PRESSURE MODEL NO.* MODEL NO. MODEL NO. MODEL NO. (0.354) 0 to 100 mV ( 10 Vdc) OUTPUT 0 to -10 inH O 0 to -25 PX409-10WVV PX419-10WVV PX429-10WVV PX459-10WVV 2 0 to -1 0 to -69 PX409-001VV PX419-001VV PX429-001VV PX459-001VV 0 to -2.5 0 to -172 PX409-2.5VV PX419-2.5VV PX429-2.5VV PX459-2.5VV 0 to -5 0 to -345 PX409-005VV PX419-005VV PX429-005VV PX459-005VV 0 to -15 0 to -1034 PX409-015VV PX419-015VV PX429-015VV PX459-015VV 0 to 5 Vdc OUTPUT** 0 to -10 inH O 0 to -25 PX409-10WV5V PX419-10WV5V PX429-10WV5V PX459-10WV5V 2 0 to -1 0 to -69 PX409-001V5V PX419-001V5V PX429-001V5V PX459-001V5V 0 to -2.5 0 to -172 PX409-2.5V5V PX419-2.5V5V PX429-2.5V5V PX459-2.5V5V 0 to -5 0 to -345 PX409-005V5V PX419-005V5V PX429-005V5V PX459-005V5V 0 to -15 0 to -1034 PX409-015V5V PX419-015V5V PX429-015V5V PX459-015V5V 4 to 20 mA OUTPUT 0 to -10 inH O 0 to -25 PX409-10WVI PX419-10WVI PX429-10WVI PX459-10WVI 2 0 to -1 0 to -69 PX409-001VI PX419-001VI PX429-001VI PX459-001VI 0 to -2.5 0 to -172 PX409-2.5VI PX419-2.5VI PX429-2.5VI PX459-2.5VI 0 to -5 0 to -345 PX409-005VI PX419-005VI PX429-005VI PX459-005VI 0 to -15 0 to -1034 PX409-015VI PX419-015VI PX429-015VI PX459-015VI ACCESSORIES MODEL NO. DESCRIPTION M12C-PVC-4-S-F-5 PVC cable, straight 4-pin M12 female connector one end, flying leads one end, 5 m (16.4 ) long, for PX459 M12C-PVC-4-R-F-5 PVC cable, right angled 4-pin M12 female connector one end, flying leads one end, 5 m (16.4 ) long, for PX459 Comes complete with 5-point NIST traceable calibration, calibrated with electrical connection up. 1 To order cable version with 2 NPT conduit fitting, specify model PX409C, no extra cost. * To order with 0 to 10 Vdc output change 5V to 10V in model number, no extra cost. ** Metric threads and ranges also available. Ordering Examples: PX409-015VV, cable termination, 0 to -15 psig vacuum range, 10 mV/V output. PX459-001V5V, M12 termination, 0 to -1 psi vacuum range, 0 to 5 Vdc output. B-19 Cable style. M1 2x1 20.2 0.8